Effect of rapid high-intensity light curing on micro-leakage in conventional and bulk-fill resin composites
Source abstract
Abstract
Purpose This study compared the effect of high-intensity (3,200 mW/cm2) and conventional-intensity (1,000 mW/cm2) light curing on the micro-leakage properties of conventional and bulk-fill resin composites. Methods Cavities were respectively prepared on the mesial and distal surfaces of 60 molars. 3M™ Filtek™ One Bulk Fill Restorative (BF), 3M™ Filtek™ Z350 XT Universal Restorative (Z350), and 3M™ Single bond universal adhesive were used to fill the molars with different light-curing modes. After temperature cycling, staining, and sectioning, the micro-leakage of these teeth was observed with a microscope. Results In the condition of adhesive at standard power, the micro-leakage of BF in both light-curing irradiation modes showed no significant differences (P > 0.05), and that of Z350 was significantly increased following high-intensity irradiation (P < 0.05). Compared with the standard mode, the micro-leakage was significantly higher (P < 0.05) for both BF and Z350 under the condition of high-intensity irradiation for adhesive. Conclusion A high-power and short-duration light mode is not suitable for all materials. The selection of the light-curing mode should be based on the material composition and physicochemical properties, determining the appropriate irradiation time and intensity to minimize micro-leakage in resin-based restorative materials and thereby ensure a favorable restoration prognosis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Photopolymerization techniques and applications · Epoxy Resin Curing Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Marginal integrity of bulk versus incremental fill class II composite restorations10.2341/14-306-l ↗
2. Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites10.1016/j.jmbbm.2018.10.026 ↗
3. Polymerization kinetics of dental adhesives cured with LED: correlation between extent of conversion and permeability10.1016/j.dental.2006.06.040 ↗
4. Marginal adaptation of class II cavities restored with bulk-fill composites10.1016/j.jdent.2014.02.007 ↗
5. Effect of light sources and curing mode techniques on sorption, solubility and biaxial flexural strength of a composite resin10.1590/s1678-77572012000200021 ↗
6. micro-leakage in class II restorations of two bulk fill resin composites and a conventional nanohybrid resin composite: an in vitro study at 10,000 thermocycles10.1186/s12903-021-01942-0 ↗
7. Influence of light-curing sources on polymerization reaction kinetics of a restorative system
8. Chemistry of novel and contemporary resin-based dental adhesives10.1016/j.jmbbm.2020.103875 ↗
9. Prolonged curing time reduces the effects of simulated pulpal pressure on the bond strength of one-step self-etch adhesives10.2341/12-180-L ↗
10. Insufficient cure under the condition of high irradiance and short irradiation time10.1016/j.dental.2008.07.007 ↗
11. In vitro evaluation of micro-leakage in Class II composite restorations: high-viscosity bulk-fill vs conventional composites10.4012/dmj.2018-160 ↗
12. Marginal integrity of flowable and packable bulk fill materials used for class II restorations -A systematic review and meta-analysis of in vitro studies10.4012/dmj.2018-180 ↗
13. Monomer release from bulk-fill composite resins in different curing protocols10.2334/josnusd.19-0221 ↗
14. Internal and marginal adaptation of high-viscosity bulk-fill composites in class II cavities placed with different adhesive strategies10.1007/s10266-018-0402-1 ↗
15. New bulk-fill composite system with high irradiance light polymerization: integrity and degree of conversion10.1016/j.dental.2020.10.012 ↗
16. Effect of high-radiant emittance and short curing time on polymerization shrinkage vectors of bulk fill composites10.2341/20-167-l ↗
17. Shrinkage behavior of a resin-based composite irradiated with modern curing units10.1016/j.dental.2004.08.007 ↗
18. A comparative study on micro-leakage of two low shrinkage composite materials in Class II cavities: a stereomicroscopic analysis10.4103/jcd.jcd_444_22 ↗
19. Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin10.2341/13-307-l ↗
20. Exposure reciprocity law in photopolymerization of multi-functional acrylates and methacrylates10.1002/macp.200600480 ↗
21. Influence of pulse-delay curing on sorption and solubility of a composite resin10.1590/s1678-77572009000100006 ↗
22. The effect of super power mode of bait laser preparation and photocuring lamp on resin micro-leakage
23. Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites10.1016/j.dental.2016.09.011 ↗
24. In vitro micro-leakage at the enamel and dentin margins of class II cavities of primary molars restored with a bulk-fill and a conventional composite10.1002/cre2.729 ↗
25. Evaluation of self-adhesive composite restorations bond on primary canines: an in vitro study10.7759/cureus.35005 ↗
26. Effect of rapid high-intensity light-curing on polymerization shrinkage properties of conventional and bulk-fill composites10.1016/j.jdent.2020.103448 ↗
27. Evaluation of bond strength, nanoleakage, and marginal adaptation of bulk-fill composites submitted to thermomechanical aging10.3290/j.jad.a42547 ↗
28. Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values10.1016/j.dental.2015.02.010 ↗
29. Effect of modulated photo-activation on polymerization shrinkage behavior of dental restorative resin composites10.1111/eos.12139 ↗
30. Dental restorative composite materials: a review10.1016/j.job.2019.04.001 ↗