An Improved Equivalent Circuit Simulation of High Frequency Ultrasound Transducer
Source abstract
Abstract
The equivalent circuit simulation plays an important role in the design of ultrasound transducer. However, the existing methods are difficult to achieve the effect of matching and backing layer, and not able to accurately simulate the transducer with cable. Especially in the application of high frequency ultrasound, the long cable has a great influence on the performance of the transducer. To overcome these limitations, this paper proposed an improved equivalent circuit method, which combined Leach model and transmission line model. It can realize the complete simulation of ultrasound transducer with a long cable, matching layer, and backing layer in PSPICE circuit simulation software when the parameters were measured. Its principles were briefly introduced, and ultrasound transducers with different frequencies (12 and 20 MHz), different matching layers, and different cable lengths (0.5–2.5 m) were designed and fabricated to verify the effectiveness of the method, which is also compared with the traditional KLM method using PiezoCAD. The experiment results showed that the long cable, matching layer, and backing layer have a significant impact on the performance of high frequency ultrasound transducers, and this proposed method has good agreement with these results. Moreover, for the simulation of the complete transducer, the effect of this method is better than KLM model. Besides, this method does not need to know the specific equivalent circuit of matching, backing layer, or cable wire, it can accurately predict the impedance and phase of the transducer through the material parameters, which is very helpful for the material selection and optimization of subsequent transducer design and fabrication. The study indicates that this improved equivalent circuit method is suitable to be applied in the general circuit simulation software and provides strong support for the high frequency transducer and system design.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Ultrasound Imaging and Elastography · Flow Measurement and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. PSpice modelling of an ultrasonic setup for materials characterization.10.1080/00150190802382058 ↗
2. Modeling and simulation of pulsed electroacoustic measurement method.10.1109/jsyst.2013.2292452 ↗
3. ABCD matrix: a unique tool for linear two-wire transmission line modelling.10.7227/ijeee.40.3.5 ↗
4. Simulation analysis of piezoelectric ceramic chip PZT based on Ansys.
5. Simulation of advanced ultrasound systems using Field II.
6. The study of cable effect on high frequency ultrasound transducer performance.10.1109/jsen.2018.2838142 ↗
7. Incorporation of diffraction effects in simulations of ultrasonic systems using PSpice models
8. Electrical tuning for sensitivity enhancement of a piezo-electric ultrasonic transducer: Simulation and fabrication.10.1007/s12206-020-0707-1 ↗
9. New equivalent circuits for elementary piezoelectric transducers.10.1049/el:19700280 ↗
10. Controlled-source analogous circuits and spice models for piezoelectric transducers.10.1109/58.265821 ↗
11. Magnusson · Transmission Lines and Wave Propagation. · 2000
12. Mason · Electromechanical Transducers and Wave Filters. · 1942
13. VHDL-AMS and PSPICE modeling of ultrasonic piezoelectric transducer for biological mediums application10.1109/ATSIP.2014.6834670 ↗
14. Intracardiac, intravascular, two-dimensional, high-frequency ultrasound imaging of pulmonary artery and its branches in humans and animals.10.1161/01.cir.81.6.2007 ↗
15. Ultrasound biomicroscopy: high-frequency ultrasound imaging of the eye at microscopic resolution.10.1016/S0033-8389(05)70230-X ↗
16. Transmission line modeling: a circuit theory approach.10.1137/s0036144597316048 ↗
17. A review of acoustic impedance matching techniques for piezoelectric sensors and transducers.10.3390/s20144051 ↗
18. Transient performance of a piezoelectric transducer.10.1121/1.1908709 ↗
19. Modeling of an ultrasonic communication system
20. Prospective assessment of the ability of endoscopic ultrasound to diagnose, exclude, or establish the severity of chronic pancreatitis found by endoscopic retrograde cholangiopancreatography.10.1016/s0016-5107(98)70123-3 ↗
21. Ultrasonic power and data transfer through multiple curved layers applied to pipe instrumentation.10.3390/s19194074 ↗
22. Lossless and lossy modeling of ultrasonic imaging system for immersion applications: Simulation and experimentation.10.1016/j.compeleceng.2018.07.054 ↗
23. A 40–100 MHz B-scan ultrasound backscatter microscope for skin imaging10.1109/ULTSYM.1993.339642 ↗
24. PSpice simulation of ultrasonic systems.10.1109/58.852085 ↗
25. PSPICE approach for designing the ultrasonic piezoelectric transducer for medical diagnostic applications.10.1016/s0924-4247(99)00067-9 ↗
26. Research and validation of design principles for PVDF wideband ultrasonic transducers based on an equivalent circuit model.10.1016/j.measurement.2019.04.050 ↗
27. Optimization of equivalent circuit model for piezoelectric ultrasonic transducer
28. Electrical Impedance Matching between Piezoelectric Transducer and Power Amplifier.10.1109/jsen.2020.3008762 ↗