Application of Magneto-Rheological Fluids for Investigating the Effect of Skin Properties on Arterial Tonometry Measurements

Adam Coon, Tae-Heon Yang, Young-Min Kim, Heeshin Kang, Jeong-Hoi Koo

Abstract

Accurate, non-invasive measurements of blood pressure and its continuous monitoring are extremely important for personal health care. Arterial tonometry, a method that is used to provide a detailed image of a patient’s cardiovascular health, shows promise for being a non-invasive alternative to current blood pressure measurement methods. However, its measurement accuracy is sensitive to patient variations such as the stiffness of the skin. Thus, this project intends to investigate the effect of skin properties (i.e., stiffness) on the accuracy of tonometric blood pressure measurements. To this end, a test platform, consisting of a pulsatile system and a tunable skin stiffness apparatus (or MR apparatus), is constructed. The cam-follower pulsatile system built based on in vivo testing of human pulses is used to generate realistic pulse waveforms. The MR apparatus is able to adjust its stiffness using Magneto-Rheological (MR) fluid whose apparent viscosity changes with applied magnetic fields. Placed at the surface of the MR apparatus, a cylinder with a frictionless plunger simulates a variable applanation force or “hold-down pressure” of tonometry by adjusting the added weights atop the cylinder. Using this test setup, a series of tests were performed by varying the input magnetic field and the weights, which effectively adjusts the skin stiffness and the hold-down pressure, respectively. The vertical displacement of the plunger caused by the internal pulse pressure was measured using a laser displacement sensor. The output displacement waveforms were analyzed with the focus on the peak amplitude difference of the waveforms, which is related to the augmentation index (a surrogate measure of arterial stiffness). The results show that there exists an “optimal” plunger weight or “hold-down pressure” that provides the most distinct output pulse waveforms. The results further show that the difference in the first two peak values decreases as the skin stiffness increases, indicating that the stiffer the skin property, the less the “hold-down pressure” effects on the accuracy of the tonometry measurements.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Cardiovascular Health and Disease Prevention · Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Blood pressure measurement10.1136/bmj.322.7292.981 ↗
2. Dynamic indentation on human skin in vivo: ageing effects10.1111/j.1600-0846.2008.00324.x ↗
3. Non-invasive continuous blood pressure monitoring: a review of current applications10.1007/s11684-013-0239-5 ↗
4. Dharmananda · 2000
5. Microflotronic arterial tonometry for continuous wearble non-invasive hemodynamic monitoring10.1007/s10439-014-1037-1 ↗
6. A literature review of the mechanical behavior of the stratum corneum, living epidermis and the subcutaneous fat tissue
7. Blood pressure as a cardiovascular risk factor prevention and treatment10.1001/jama.1996.03530440051036 ↗
8. Model of the viscoelastic behaviour of skin in vivo and study of anisotropy10.1111/j.1600-0846.2004.00057.x ↗
9. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit10.1007/s00392-015-0816-5 ↗
10. Blood pressure measurement device based on the arterial tonometry method with micro triaxial force sensor10.1109/Transducers.2013.6627287 ↗
11. Computational study to investigate effect of tonometer geometry and patient-specific variability on radial artery tonometry10.1016/j.jbiomech.2017.04.023 ↗
12. Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses10.1161/01.HYP.0000084051.34269.A9 ↗
13. Differences in effects of age and blood pressure on augmentation index10.1093/ajh/hpu082 ↗
14. Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement10.1093/bja/76.3.405 ↗
15. Tissue-informative mechanism for wearable non-invasive continuous blood pressure monitoring10.1038/srep06618 ↗
16. A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms10.1186/s12938-018-0620-3 ↗
17. Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests10.1111/j.1600-0846.2008.00329.x ↗