In this article, we report our comparative study on the electro-optical properties between the conventional patterned vertical alignment (PVA) cell and super-patterned vertical alignment (S-PVA) cell. Electro-optical properties of these cells are calculated with 3D FEM numerical solver, TechWiz LCD, which is commercially available in the market. Our simulation results implies that the color difference of S-PVA can be improved by more than 13% over the traditional PVA cell since S-PVA mode has twice as many domains as the conventional PVA mode.