Lateral impact response of circular hollow steel tubes with mid-span localized penetrating notches
Source abstract
Abstract
In this study, 32 numerical models of CHST columns were established in the ABAQUS program to evaluate the effect of mid-span local defects on the impact resistance of circular hollow steel tube (CHST) columns. The simulation studies were conducted from three aspects: notch length, notch angle, and impact energy. The results showed that under a lateral impact load, the mid-span of the CHST column presented global bending failure patterns accompanied by local indentation deformation in the impact region and local buckling deformation at the bottom of the fixed end. Compared with the mid-span indentation displacement of the non-notch model, when the impact velocities were 30 km/h and 60 km/h, the horizontal notch model surpassed the maximum by 29.3% and 36.3%, the oblique notch model surpassed the maximum by 47.8% and 115.6%, and the vertical notch model only increased by 9.7% and 1.1%. The local damage area and impact force time-history curves of the vertical notch model agreed well with those of the non-notch model. Among the three notch angles, the impact plateau values of the vertical notch model and the global bending displacement in the mid-span were least affected by the notch length, notch location, and impact energy. The energy absorption of the CHST column was mainly due to indentation deformation in the mid-span, and the global bending deformation was auxiliary. Compared with the energy absorption ratio (EAR) of the non-notch model, with increased impact energy, the EAR of the vertical notch model increased by 20.2%, 13.5%, and 17.3% on average. The horizontal and oblique notch models decreased by 28.2%, 61.0%, 42.4%, and 29.1%, 62.7%, and 49.3%, respectively. The Rd of all notch models showed an overall upward trend as the impact energy increased, and the Rd of the horizontal notch model increased the most. According to the parametric analysis results, the dynamic flexural capacity prediction formula of the CHST columns section was obtained, considering the influence of notch length, notch angle, and impact energy within the parameter range of this study.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Response to Dynamic Loads · High-Velocity Impact and Material Behavior · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Residual compressive strength of inclined steel tubular members with local corrosion10.1016/j.apor.2016.07.002 ↗
2. A numerical study of the behaviour and failure modes of axially compressed steel columns subjected to transverse impact10.1016/j.ijimpeng.2011.03.005 ↗
3. Hollow and concrete filled steel hollow sections under transverse impact loads10.1016/j.engstruct.2008.04.003 ↗
4. Study on seismic performance of concrete filled square steel tubes subjected to simulated acid rain attack
5. Study on the residual bearing capacity and damage of concrete-filled steel tube (CFST) column subjected to transverse impact10.13614/j.cnki.11-1962/tu.2021.05.002 ↗
6. Behavior of circular CFST stub columns under sustained load and chloride corrosion10.1016/j.jcsr.2014.07.021 ↗
7. Hou · 2012
8. Flexural behavior of circular concrete filled steel tubes (CFST) under sustained load and chloride corrosion10.1016/j.tws.2016.02.020 ↗
9. Full-range analysis on square CFST stub columns and beams under loading and chloride corrosion10.1016/j.tws.2013.03.003 ↗
10. The probabilistic life time prediction model of oil pipeline due to local corrosion crack10.1016/j.tafmec.2014.04.002 ↗
11. Ultimate capacity of rectangular plates with partial depth pits under uniaxial loads10.1016/j.marstruc.2011.12.005 ↗
12. Jones · 1997
13. Behavior of CFDST stub columns under preload, sustained load and chloride corrosion10.1016/j.jcsr.2014.12.023 ↗
14. A parametric study on effects of pitting corrosion on steel plate's ultimate strength10.1016/j.apor.2019.102026 ↗
15. Ultimate strength assessment of corroded box girders10.1016/j.oceaneng.2012.09.019 ↗
16. Performance of square concrete-filled steel tubular columns under repeated lateral impact10.1016/j.engstruct.2023.115719 ↗
17. Axial behavior of circular steel tube with localized penetrating corrosion simulated by artificial notch10.1016/J.TWS.2022.108944 ↗
18. Galvanic corrosion induced localized defects and resulting strength reduction of circular steel tubes under axial compression: an experimental study10.1016/j.tws.2020.106881 ↗
19. Experimental and numerical study of localized pitting effect on compressive behavior of tubular members10.1016/j.marstruc.2020.102784 ↗
20. Experimental behavior of cement filled pipe-in-pipe composite structures under transverse impact10.1016/j.ijimpeng.2014.05.004 ↗
21. Modeling progressive failure and crack evolution in a randomly distributed fiber system via a coupled phase-field cohesive model10.1016/j.compstruct.2023.116959 ↗
22. Modeling via peridynamics for large deformation and progressive fracture of hyperelastic materials10.1016/j.cma.2022.115739 ↗
23. Circular concrete filled steel tubular (CFST) columns under cyclic load and acid rain attack: test simulation10.1016/j.tws.2017.10.005 ↗
24. Lateral impact response of concrete-filled square steel tubes with local defects10.3390/buildings12070996 ↗
25. Axially pre-loaded steel tubes subjected to lateral impacts: an experimental study10.1016/s0734-743x(01)00157-9 ↗