journal article·2018-02-16Open access

Trabecular Fracture Zone Might Not Be the Higher Strain Region of the Trabecular Framework

Simone Tassani, Martino Pani, Jerome Noailly, Miguel Angel Gonzalez Ballester

Abstract

Trabecular bone fracture is a traumatic and localized event studied worldwide in order to predict it. During the years researchers focussed over the mechanical characterization of the trabecular tissue to understand its mechanics. Several studies pointed out the very local nature of the trabecular failure, finally identifying the fracture zone with the aim to study it separately. The complexity of the three-dimensional trabecular framework and the local nature of the fracture event do not allow the direct evaluation of a single trabecula’s behaviour within its natural environment. For this reason, micro-Finite Element Modelling have been seen as the best way to investigate this biomechanical issue. Mechanical strain analysis is adopted in the literature for the identification of micro fracture using criteria based on principal strains. However, it was never verified if the fracture zone is actually the zone where principal strains are concentrated. Here we show how the maximum strain of the tissue might not be directly correlated to the fracture. In the present work a previously validated technique was used to identify the fracture zone of 10 trabecular specimen mechanically tested in compression and scanned in micro-CT before and after the mechanical test. Before-compression datasets were used to develop 10 micro-FE models were the same boundary conditions of the mechanical test were reproduced. Our results show how the known linear behaviour of the trabecular framework might not be directly related to the development of the fracture suggesting other non-linear phenomenon, like buckling or micro-damage, as actual cause of the traumatic event. This result might have several implications both in micro-modelling and in clinical applications for the study of fracture related pathology, like osteoporosis.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone and Joint Diseases · Bone health and osteoporosis research · Bone health and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Variations in trabecular bone composition with anatomical site and age: potential implications for bone quality assessment10.1677/joe.0.1550411 ↗
2. Prediction of bone strength by micro-CT and MDCT-based finite-element-models: how much spatial resolution is needed?10.1016/j.ejrad.2013.10.024 ↗
3. The sensitivity of nonlinear computational models of trabecular bone to tissue level constitutive model10.1080/10255842.2015.1041022 ↗
4. Mechanisms of uniformity of yield strains for trabecular bone10.1016/j.jbiomech.2004.02.045 ↗
5. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
6. Intravoxel bone micromechanics for microCT-based finite element simulations10.1016/j.jbiomech.2013.06.036 ↗
7. Age-related changes in femoral trabecular bone in arthrosis10.3109/17453679008993554 ↗
8. Enhanced trabecular micro-architecture of the femoral neck in hip osteoarthritis vs. healthy controls: a micro-computer tomography study in postmenopausal women10.1007/s00264-012-1713-4 ↗
9. Locations of bone tissue at high risk of initial failure during compressive loading of the human vertebral body10.1016/j.bone.2007.05.017 ↗
10. Multiple loading conditions analysis can improve the association between finite element bone strength estimates and proximal femur fractures: a preliminary study in elderly women10.1016/j.bone.2014.06.038 ↗
11. Negative results are disappearing from most disciplines and countries10.1007/s11192-011-0494-7 ↗
12. Influence of the degradation of the organic matrix on the microscopic fracture behavior of trabecular bone10.1016/j.bone.2004.05.027 ↗
13. “A highly scalable matrix-free multigrid solver for µFE analysis based on a pointer-less octree,”10.1007/978-3-642-29843-1_56 ↗
14. Application of fracture mechanics concepts to hierarchical biomechanics of bone and bone-like materials10.1007/s10704-006-7156-4 ↗
15. The mechanical behaviour of cancellous bone10.1016/0021-9290(85)90287-8 ↗
16. Finite element models predict the location of microdamage in cancellous bone following uniaxial loading10.1016/j.jbiomech.2015.10.023 ↗
17. Role of bone in osteoarthritis pathogenesis10.1016/j.mcna.2008.09.006 ↗
18. Morphology-elasticity relationships using decreasing fabric information of human trabecular bone from three major anatomical locations10.1007/s10237-012-0443-2 ↗
19. Micro-CT finite element model and experimental validation of trabecular bone damage and fracture10.1016/j.bone.2013.06.028 ↗
20. The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties10.1016/S8756-3282(02)00782-2 ↗
21. Failure modelling of trabecular bone using a non-linear combined damage and fracture voxel finite element approach10.1007/s10237-012-0394-7 ↗
22. Mathematical relationships between bone density and mechanical properties: a literature review10.1016/j.clinbiomech.2007.08.024 ↗
23. Fast estimation of Colles’ fracture load of the distal section of the radius by homogenized finite element analysis based on HR-pQCT10.1016/j.bone.2017.01.003 ↗
24. Why most published research findings are false10.1371/journal.pmed.0020124 ↗
25. Evaluation of trabecular microarchitecture in nonosteoporotic postmenopausal women with and without fracture10.1002/jbmr.1595 ↗
26. Effects of thresholding techniques on microCT-based finite element models of trabecular bone10.1115/1.2746368 ↗
27. Negative results: null and void10.1038/422554a ↗
28. Yield strain behavior of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
29. A new Ensemble Classification System for fracture zone prediction using imbalanced micro-CT bone morphometrical data10.1109/JBHI.2017.2723463 ↗
30. Micro-structural basis for particular vulnerability of the superolateral neck trabecular bone in the postmenopausal women with hip fractures10.1016/j.bone.2011.09.044 ↗
31. Micro-compression: a novel technique for the nondestructive assessment of local bone failure10.1016/S0021-9290(98)80302-3 ↗
32. Trabecular bone microdamage and microstructural stresses under uniaxial compression10.1016/j.jbiomech.2004.05.013 ↗
33. Functional dependence of cancellous bone shear properties on trabecular microstructure evaluated using time-lapsed micro-computed tomographic imaging and torsion testing10.1002/jor.20931 ↗
34. The interaction of microstructure and volume fraction in predicting failure in cancellous bone10.1016/j.bone.2006.06.013 ↗
35. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
36. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements10.1016/j.jbiomech.2006.11.020 ↗
37. The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone10.1016/j.clinbiomech.2008.07.007 ↗
38. Structural parameters and mechanical strength of cancellous bone in the femoral head in osteoarthritis do not depend on age10.1016/j.bone.2007.07.014 ↗
39. MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters10.1111/j.1365-2818.2007.01731.x ↗
40. Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur10.1016/j.jbiomech.2007.08.003 ↗
41. Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images10.1016/S8756-3282(02)00736-6 ↗
42. Buckling of adaptive elastic bone-plate: theoretical and numerical investigation10.1007/s10237-004-0056-5 ↗
43. Shear strength behavior of human trabecular bone10.1016/j.jbiomech.2012.07.023 ↗
44. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro10.1016/j.jbiomech.2007.09.009 ↗
45. Assessing methods for characterising local and global structural and biomechanical properties of the trabecular bone network10.2174/092986711796504754 ↗
46. Modeling the mechanical behavior of vertebral trabecular bone: effects of age-related changes in microstructure10.1016/S8756-3282(97)00100-2 ↗
47. “Mechanisms of trabecular bone failure in the osteoporotic lumbar vertebral body,”
48. On the importance of geometric nonlinearity in finite-element simulations of trabecular bone failure10.1016/S8756-3282(03)00214-X ↗
49. 3D identification of trabecular bone fracture zone using an automatic image registration scheme: a validation study10.1016/j.jbiomech.2012.05.019 ↗
50. The micro-structure of bone trabecular fracture: an inter-site study10.1016/j.bone.2013.12.007 ↗
51. Anisotropy and inhomogeneity of the trabecular structure can describe the mechanical strength of osteoarthritic cancellous bone10.1016/j.jbiomech.2009.11.034 ↗
52. Volume to density relation in adult human bone tissue10.1016/j.jbiomech.2010.08.032 ↗
53. 3D characterization of bone strains in the rat tibia loading model10.1007/s10237-011-0320-4 ↗
54. Buckling studies of single human trabeculae10.1016/0021-9290(75)90025-1 ↗
55. The thenar muscles – new findings10.1007/BF01794759 ↗
56. Comparison of micro-level and continuum-level voxel models of the proximal femur10.1016/j.jbiomech.2005.10.027 ↗
57. Micro-finite element simulation of trabecular-bone post-yield behaviour – effects of material model, element size and type10.1080/10255840701848756 ↗
58. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
59. The role of collagen in bone strength10.1007/s00198-005-2035-9 ↗
60. Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in men10.1002/jbmr.297 ↗
61. Fabric-based Tsai-Wu yield criteria for vertebral trabecular bone in stress and strain space10.1016/j.jmbbm.2012.07.005 ↗
62. Valid micro finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions10.1016/j.jbiomech.2010.02.026 ↗
63. Finite element analysis for prediction of bone strength10.1038/bonekey.2013.120 ↗