journal article·2022-09-20Open access

Hurdles and limitations for design of a radial permeameter conforming to the benchmark requirements

Pedro Sousa, Stepan V. Lomov, Jan Ivens

Abstract

Experimental permeability measurements saw a considerable increase in accuracy when recommendations and guidelines were imposed upon the realization of two international benchmarks. Such requirements aid the design stage and experimental validation of a permeameter rig however, systematic errors in the measurements still compromise the comparability of measurements obtained by different radial permeameter rigs. Owing to hurdles and limitations in the data acquisition system, validation of the mold cavity and fluid injection system, optical errors in the visual tracking of a flow front, and uncertainties in the measurement of the fluid viscosity, the measurement’s accuracy is yet lower than the required for a standardized process. In this study, the detailed study and calibration of such parameters was able to identify and minimize error sources that would otherwise result in undetected systematic deviations from the expected results. In conclusion, the verification proposed by the radial benchmark does not guarantee the accuracy of the measurement, as the error in the instruments proposed for the verification is comparable to the requirements themselves. This creates a certain uncertainty in the verification that needs to be tackled with more detailed measurement protocols to ensure not only the compliance with the measurement requirements but also to set the limits of the attainable accuracy. The rig was validated by measuring the permeability of the fabric reinforcements used in the radial benchmark exercise. Due to the scattering in the results reported in the benchmark exercise, 13 out of the 19 reported values were excluded to obtain a good estimation of the expected permeability for each volume fraction. Although the rig complied with all recommendations currently in place, the obtained permeability showed a 20% deviation in the K1 direction, while the K2 was within the expected range for the average value. The observed deviation was later found to be caused by an optical distortion, which affected the measurement of the real-world flow front dimensions. A correction for this deviation needs further systematic investigation, also a possible revision of the future standard since a correction for optical distortions is yet not included in the measurement guidelines.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surface Roughness and Optical Measurements · Industrial Vision Systems and Defect Detection · Sports Performance and Training

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Experimental determination of the permeability of textiles: A benchmark exercise10.1016/j.compositesa.2011.04.021 ↗
2. Converter · 2005
3. Image processing and data evaluation algorithms for reproducible optical in-plane permeability characterization by radial flow experiments10.1177/0021998318780209 ↗
4. Compressibility measurement of composite reinforcements for flow simulation of vacuum infusion10.1002/pc.24770 ↗
5. 2022
6. A comparative analytical, numerical and experimental analysis of the microscopic permeability of fiber bundles in composite materials
7. In-plane permeability characterization of engineering textiles based on radial flow experiments: A benchmark exercise10.1016/j.compositesa.2019.03.006 ↗
8. A new methodology for race-tracking detection and criticality in resin transfer molding process using pressure sensors10.1177/0021998318774829 ↗
9. Methodology of dry and wet compressibility measurement10.1016/j.compositesa.2019.105672 ↗
10. Efficient experimental characterisation of the permeability of fibrous textiles10.1177/0021998316630801 ↗
11. Experimental determination of the permeability of engineering textiles: Benchmark II10.1016/j.compositesa.2014.02.010 ↗
12. Weitzenbock* · Radial flow permeability measurement. Part B: ApplicationCompos Part A [Internet] · 1998 · 30 · 797
13. Radial flow permeability measurement. Part A: Theory10.1016/s1359-835x(98)00183-3 ↗
14. Pressure-controlled compaction characterization of fiber preforms suitable for viscoelastic modeling in the vacuum infusion process10.1177/0021998316685164 ↗
15. A flexible new technique for camera calibration10.1109/34.888718 ↗