journal article·2022-10-11Open access

Fire resistance of composite shear walls filled with demolished concrete lumps and self-compacting concrete

Yan Xiong, Yaxin Chen, Bo Wu, Guowei Zhao

Abstract

The recycling and reuse of waste concrete is conducive to promoting the sustainable development of resources and practicing the concept of green development. Demolished concrete lumps (DCLs) and self-compacting concrete (SCC) made from waste concrete take full advantage of their recyclability. In order to fully utilize the advantages of demolished concrete lumps and self-compacting concrete in construction, applying demolished concrete lumps and self-compacting concrete to composite shear wall structures is an effective way to reduce costs and improve industrial production. In this paper, a new composite shear wall filled with demolished concrete lumps and self-compacting concrete is proposed, and its fire performance is investigated. The shear wall combines edge constraints of concrete-filled steel tubes, demolished concrete lumps and self-compacting concrete. In order to facilitate the mass pouring of demolished concrete lumps, a cavity is formed between the steel tubes at the ends and the precast walls on both sides. A double-sided fire tests was conducted on three composite shear wall specimens filled with demolished concrete lumps and self-compacting concrete at a constant axial compression ratio, where the fire-retardant coating and the wall width-to-depth ratio were considered as the main test parameters. The specimens were able to steadily withstand the predetermined axial loads during the fire resistance time of 180 min and showed good fire resistance. The concrete temperature variation trends of the three specimens in the wall section were basically the same. The fire-retardant coating on the concealed column had a significant effect on the section temperature of the steel tube, while increasing the wall width-to-depth ratio had little effect. When the axial compression ratio was 0.19, the specimens were in the expansion stage within 180 min and no compression occurred. The results show that the expansion deformation of the shear wall sprayed with fire-retardant coating on the outer surface of the concealed column is smaller than that of the shear wall without fire-retardant coating, and the axial deformation of the composite shear wall infilled with demolished concrete lumps and self-compacting concrete is not affected by increasing the wall width-to-depth ratio.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Mechanical characteristics of self-compacting concretes with different filler materials, exposed to elevated temperatures10.1617/s11527-008-9459-6 ↗
2. On the structural behavior of reinforced concrete walls exposed to fire10.4028/www.scientific.net/kem.711.580 ↗
3. Structural performance of reinforced concrete walls under fire conditions10.1061/(asce)st.1943-541x.0002519 ↗
4. Experimental investigation on fire resistance of sandwich composite walls with truss connectors10.1016/j.jcsr.2021.107052 ↗
5. Fire-resistance property of reinforced lightweight aggregate concrete wall10.1016/j.conbuildmat.2011.12.081 ↗
6. Fire resistance of concrete walls with light aggregate10.1108/jsfe-11-2017-0043 ↗
7. Effect of axial compression ratio on concrete-filled steel tube composite shear wall10.1177/1369433218796407 ↗
8. Compressive behavior of compound concrete containing demolished concrete lumps and recycled aggregate concrete10.1016/j.conbuildmat.2020.121624 ↗
9. Effect of wall thickness on thermal behaviors of RC walls under fire conditions10.1007/s40069-016-0164-5 ↗
10. Analytical studies for the effect of thickness and axial load on load bearing capacity of fire damaged concrete walls with different sizes10.1080/24705314.2019.1603189 ↗
11. Modeling the behavior of load bearing concrete walls under fire exposure10.1016/j.conbuildmat.2017.08.010 ↗
12. Experimental observations on reinforced concrete bearing walls subjected to all-sided fire exposure10.1680/macr.12.00013 ↗
13. Chemical–mineralogical characterisation of coarse recycled concrete aggregate10.1016/j.wasman.2006.01.005 ↗
14. Post-fire cyclic behavior of reinforced concrete shear walls10.1007/s11771-010-0603-4 ↗
15. A study on structural behavior of reinforced concrete walls exposed to hydrocarbon fire under vertical load
16. Numerical modeling of three reinforced concrete bearing wall tests subject to one-sided standard fire10.14359/51716756 ↗
17. Metallic materials-tensile testing
18. Testing of normal- and high-strength concrete walls subjected to both standard and hydrocarbon fires10.14359/51685607 ↗
19. Performance of high-strength concrete walls exposed to fire10.1177/1369433217732500 ↗
20. Impact of physical seismic damage on the fire resistance of reinforced concrete walls10.1016/j.conbuildmat.2018.06.120 ↗
21. Experimental assessment of the seismic performance of a prefabricated concrete structural wall system10.1016/j.engstruct.2011.02.043 ↗
22. Effect of heated areas on thermal response and structural behavior of reinforced concrete walls exposed to fire10.1016/j.engstruct.2020.110165 ↗
23. Assessment of the development level of regional industrialized building based on cloud model: A case study in Guangzhou, China10.1016/j.jobe.2021.102547 ↗
24. Structure behavior of concrete filled double-steel-plate composite walls under fire10.1177/1369433218825238 ↗
25. Axial loading tests of thin-walled circular steel tubes infilled with cast-in-place concrete and precast segments containing DCLs10.1016/j.tws.2018.02.008 ↗
26. Compressive behaviors of cubes and cylinders made of normal-strength demolished concrete blocks and high-strength fresh concrete10.1016/j.conbuildmat.2015.01.027 ↗
27. Fire resistance and post-fire seismic behavior of high strength concrete shear walls10.1007/s10694-016-0582-6 ↗