Experimental and numerical analysis on frost heave cracking of prestressed high-strength concrete (PHC) pipe piles in cold regions
Source abstract
Abstract
With the depletion of global fossil energy and the rapid development of photovoltaic power, prestressed high-strength concrete (PHC) pipe piles are widely applied in photovoltaic projects due to their superior mechanical properties and ease of construction. However, PHC pipe piles in cold regions face severe challenges of vertical cracks, which reduce the bearing capacity of the piles and threaten the safe operation of photovoltaic equipment. Motivated by a field case study of extensive cracking at a large-scale photovoltaic site, this paper investigates the failure mechanism through a combination of laboratory experiments and finite element (FE) analysis. The results reveal that the freezing and expansion of a sufficient volume of accumulated internal water is the necessary and definitive condition for vertical cracking, while pre-existing defects act only as promoting factors. A critical water level threshold for cracking was identified, and a subsequent parametric analysis demonstrated that this threshold is highly sensitive to design parameters. Specifically, the critical water level increases significantly with greater wall thickness and higher concrete strength, but is largely unaffected by the level of axial prestress. The findings are corroborated by the field data, which shows a strong correlation between the highest rates of pile failure and water-rich environmental conditions. This study provides a quantitative framework for engineers to assess the risk of frost heave and offers a scientific basis for developing effective preventive measures to enhance the durability of photovoltaic infrastructure in cold regions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dam Engineering and Safety · Geotechnical Engineering and Underground Structures · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. 2016
2. Novel explicit models for assessing the frictional resistance of pipe piles subjected to seismic effects10.1016/j.jnlssr.2024.06.010 ↗
3. Limit states design of pile foundations in clay under combined action of transient uplift loads and frost jacking
4. Standard test method for resistance of concrete to rapid freezing and thawing10.1520/C0666_C0666M-15 ↗
5. Effect of freeze-thaw cycling on fatigue behaviour in concrete10.1088/1757-899X/652/1/012028 ↗
6. Code for design of concrete structures: gb50010-2010 2015 edition
7. Seismic performance comparison of pile supported slab viaduct with PHC pile and RC bored pile in south part of Java island10.1007/978-981-16-7924-7_47 ↗
8. Foundations in permafrost of northern Canada: review of geotechnical considerations in current practice and design examples10.3390/geotechnics4010015 ↗
9. Experimental and numerical investigations on the mechanical response of full-scale PHC pile foundations for solar power generation10.1007/s11440-024-02257-4 ↗
10. Geocryolab - cold regions geomorphology and geotechnical laboratory - studying cold regions dynamics and their impact on northern infrastructure10.13140/2.1.4578.5927 ↗
11. Comparison of different frost models with hygrothermal simulations to better understand frost damage in porous building materials10.1016/j.buildenv.2024.111399 ↗
12. Influence of cracks on the mechanical properties of phc pipe piles of water surface photovoltaic supports in cold regions10.12226/j.issn.1001-4500.2021.01.20200615 ↗
13. Study of the pore water pressure development characteristics of phc pipe piles in soft soil foundations10.3390/buildings14071976 ↗
14. Cracking mechanism of phc pipe piles for floating photovoltaic supports in cold regions
15. Evaluation of bearing capacity of phc pipe piles via the dynamic and static loading test10.3389/feart.2023.1130294 ↗
16. Static load test and numerical analysis of influencing factors of the ultimate bearing capacity of PHC pipe piles in multilayer soil10.3390/su132313166 ↗
17. Research on dynamic pile-driving formula parameters and driving feasibility of extra-long phc pipe piles10.3390/buildings13051302 ↗
18. Bearing performance of prestressed high-strength concrete pipe pile cap connections under truncated pile conditions10.3390/buildings14051430 ↗
19. Solar effects on frost-thaw patterns at two adjacent roadway test sections: case study10.1061/9780784479315.018 ↗
20. Prestressed concrete pipe piles national standard Design Atlas
21. Analysis on shear failure of phc piles under different levels of axial load ratios
22. Assessing climate change effects on freeze-thaw exposure of concrete structures10.2478/ncr-2025-0005 ↗
23. Study on the freezing resistance and repair technology of prestressed high-strength concrete pipe piles10.1088/1742-6596/2713/1/012041 ↗
24. Analysis and treatment of crack causes in phc pipe piles for photovoltaic supports
25. Investigation and analysis of cracks in prestressed pipe pile foundations of photovoltaic supports
26. Field and numerical study of the bearing capacity of pre-stressed high-strength concrete (phc)-pipe-pile-reinforced soft soil foundations with tie beams10.3390/app132111786 ↗
27. Causes and treatment measures for damage to pipe pile foundations in cold regions