X-ray fluorescence analysis of chalcogenide glass with electron beam fluorescence excitation
Source abstract
Abstract
The method of X-ray fluorescence analysis with the fluorescence excitation by an electron beam with 30 keV energy was used to determine the germanium, arsenic, and selenium content in the Ge1–x Se x , As1–x Se x , and Ge1–x–y AsySe x glassy alloys. This technique allows determining the quantitative glass composition with an accuracy of ±0.0002 in the surface layer of a depth of ~0.1 µm from parameters x and y of the linear calibration dependences.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Phase-change materials and chalcogenides · Glass properties and applications · Luminescence Properties of Advanced Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (4)
Show source-provided references
1. Bordovsky, G.A., Marchenko, A.V., Seregin, P.P., Smirnova, N.N., and Terukov, E.I., Determination of the composition of binary chalcogenide glasses by X-ray fluorescence analysis, Semiconductors, 2010, vol. 44, no. 1, pp. 26–29.10.1134/S1063782610010021 ↗
2. Bordovskii, G.A., Marchenko, A.V., Kozhokar, M.Yu., Nasredinov, F.S., and Seregin, P.P., Composition determination of multicomponent chalcogenide glassy semiconductors with X-ray fluorescence analysis, Glass Phys. Chem., 2013, vol. 39, no. 4, pp. 377–381.10.1134/S1087659613040056 ↗
3. Blokhin, M.A. and Shveitser, I.G., Rentgenospektral’nyi spravochnik (A Reference Book on X-ray Spectroscopy), Moscow: Nauka, 1982.
4. Vainshtein, L.A., Sobel’man, I.I., and Yukov, E.A., Vozbuzhdenie atomov i ushirenie spektral’nykh linii (Excitation of Atoms and Broadening of Spectral Lines), Moscow: Nauka, 1979.