Nondestructive assessment and imaging methods for internal inspection of timber. A review.
Source abstract
Abstract
Abstract This paper reviews state-of-the-art in nondestructive testing (NDT) and semidestructive testing (SDT) methods applicable for imaging the condition of structural timber. Both NDT and SDT imaging reveal defects, damages, and decay, while the extent of wood decay can also be quantified. Combined with an appropriate data interpretation concerning the internal defects, the mechanical properties of the material can also be assessed. The possibilities and limitations of the most relevant individual NDT and SDT methods, also in combination with each other, are outlined and compared. To facilitate comparison, many observations are reported based on the same test specimen.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geophysical Methods and Applications · Non-Destructive Testing Techniques · Thermography and Photoacoustic Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Federal Institute for Materials Research and Testing (BAM) , Unter den Eichen 87 , 12205 Berlin , Germany
References (56)
Show source-provided references
1. Al Hagrey, S. (2006) Electrical resistivity imaging of tree trunks. Near Surf. Geophys. 4:179–187.
2. Arriaga, F., Llana, D.F., Esteban, M., Iniguez-Gonzalez, G. (2017) Influence of length and sensor positioning on acoustic time-of-flight (ToF) measurement in structural timber. Holzforschung 71:713–723.10.1515/hf-2016-0214 ↗
3. Bucur, V. (2003) Ultrasonic imaging. In: Nondestructive Characterization and Imaging of Wood, Chapter 5. Ed. Timell, T.E. Springer-Verlag, Berlin. pp. 181–214.10.1007/978-3-662-08986-6_5 ↗
4. Bucur, V. (2005) Theory of and experimental methods for the acoustic characterization of wood. In: Acoustics of Wood. Eds. Timell, T.E., Wimmer, R. Springer-Verlag, Berlin. pp. 39–104.
5. Dackermann, U., Li, J., Tannert, T., Crews, K., Riggio, M., Kasal, B., Rinn, F. (2014) In situ assessment of structural timber using stress-wave measurements. Mater. Struct. 47:787–803.
6. Dackermann, U., Yu, Y., Li, J., Niederleithinger, E., Wiggenhauser, H. A New Non-Destructive Testing System Based on Narrow-Band Frequency Excitation for the Condition Assessment of Pole Structures using Frequency Response Functions and Principle Component Analysis. In NDT-CE, Berlin, Germany, 2015.
7. Demming, M., Solbrig, K., Frühwald, K., Hilger, T. Grundlegende Untersuchung zur Anwendung der Millimeterwellen- und Terahertz Technologie an Holz und Holzwerkstoffen. In DGZfP-Jahrestagung, Dresden, Germany, 2013.
8. Feio, A.O., Lourenço, P.B., Machado, J.S. (2007) Non-destructive evaluation of the mechanical behavior of chestnut wood in tension and compression parallel to grain. Int. J. Archit. Herit. 1:1–47.
9. Görlacher, R., Hättrich, R. (1990) Die Bohrwiderstandsmessung. Bauen mit Holz 6:455–459.
10. Guddanti, S., Chang, S.J. (1998) Replicating sawmill sawing with TOPSAW using CT images of a full-length hardwood log. Forest Prod. J. 48:72–75.
11. Hans, G., Redman, D., Leblon, B., Nader, J., La Rocque, A. (2015) Determination of log moisture content using ground penetrating radar (GPR). Part 1. Partial least squares (PLS) method. Holzforschung 69:1117–1123.10.1515/hf-2014-0286 ↗
12. Hasenstab, A. Integritätsprüfung von Holz mit dem zerstörungsfreien Ultraschallechoverfahren. Dissertation, Bundesanstalt für Materialprüfung und -prüfung, Technische Universität Berlin, Berlin, 2006.10.1002/bate.200690234 ↗
13. Hasenstab, A., Redmer, B. (2016) Radiografie im Bauwesen und Kombination anderer ZfP-Verfahren. In: Praktische Anwendungen Zerstörungsfreier Prüfungen und Zukunftsaufgaben. DGZfP, Berlin.
14. Hasenstab, A., Homburg, S., Maierhofer, C., Arndt, R. (2007) Holzkonstruktionen mit Radar und Thermografie zerstörungsfrei untersuchen. In: Zerstörungsfreie Prüfung in Forschung, Entwicklung und Anwendung. DGZfP, Fürth.
15. Kasal, B., Tannert, T. In Situ Assessment of Structural Timber. Vol. 7. Springer, Berlin Heidelberg New York, 2011.10.1007/978-94-007-0560-9 ↗
16. Kloiber, M., Reinprecht, L., Hrivnak, J., Tippner, J. (2016) Comparative evaluation of acoustic techniques for detection of damages in historical wood. J. Cult. Herit. 20:622–631.
17. Kolkoori, S., Wrobel, N., Zscherpel, U., Ewert, U. (2015) A new X-ray backscatter imaging technique for non-destructive testing of aerospace materials. NDT and E Int. 70:41–52.10.1016/j.ndteint.2014.09.008 ↗
18. Krause, M., Mayer, K., Ballier, G., Borchardt, K., Chinta, P., Effner, U., Milmann, B., Müller, S., Nowak, T. Hochgenaue Strukturerkennung von Holzbauteilen mit 3D-Ultraschall. In Bauforschung für die Praxis. Forschungsinitiative Zukunft Bau, Stuttgart, 2014, p. 105.
19. Krause, M., Dackermann, U., Li, J. (2015) Elastic wave modes for the assessment of structural timber: ultrasonic echo for building elements and guided waves for pole and pile structures. Struct. Health Monit. 5:221–249.10.1007/s13349-014-0087-2 ↗
20. Lee, S., Lee, S.J., Lee, J.S., Kim, K.B., Lee, J.J., Yeo, H. (2011) Basic study on nondestructive evaluation of artificial deterioration of a wooden rafter by ultrasonic measurement. J. Wood Sci. 57:387–394.10.1007/s10086-011-1186-x ↗
21. Li, L., Wang, X.P., Wang, L.H., Allison, R.B. (2012) Acoustic tomography in relation to 2D ultrasonic velocity and hardness mappings. Wood Sci. Technol. 46:551–561.
22. Lualdi, M., Zanzi, L., Binda, L. (2003) Acquisition and processing requirements for high quality 3D reconstructions from GPR investigations. In: Symposium Non-Destructive Testing in Civil Engineering. DGZfP, Berlin.
23. Macchioni, N., Mannucci, M., Olmi, R., Palanti, S., Riminesi, C. (2013) Microwave reflectometric tool for non-destructive assessment of decay on timber structures. Adv. Mat. Res. 778:281–288.
24. Mai, T.C., Sbartai, Z.M., Bos, F., Razafindratsima, S., Demontoux, F. (2014) Non destructive evaluation of timber structures using GPR technique. In: Proceedings of the 15th International Conference on Ground Penetrating Radar. IEEE, Brussels, Belgium. pp. 218–222.10.1109/ICGPR.2014.6970417 ↗
25. Maia, O.M.D., Schneider, F.K., Maia, J.M., Neves, L.C., Penteado, S.D.C. (2014) Wood characterization using the power spectral density and phase velocity of ultrasonic signals. In: International Ultrasonics Symposium Proceedings. Ed. Paraná, F.U.o.T. Curitiba, Brasil, pp. 1416–1419.10.1109/ULTSYM.2014.0350 ↗
26. Martin, T. (2009a) Anwendung des komplexen elektrischen Widerstandsverfahrens an Eichen. Ed. B. B. f. M. u. -prüfung. Vol. 54. Berlin.
27. Martin, T. (2009b) Complex resistivity (CR) of wood and standing trees. In: Non-Destructive Testing in Civil Engineering. Ed. NDTCE. Nantes, France.
28. Martin, T. (2010) Complex resistivity measurements on oak. Eur. J. Wood Wood Prod. 70:45–53.10.1007/s00107-010-0493-z ↗
29. Martínez-Sala, R., Rodríguez-Abad, I., Barra, R.D., Capuz-Lladró, R. (2013) Assessment of the dielectric anisotropy in timber using the nondestructive GPR technique. Constr. Build. Mater. 38:903–911.
30. Mestre, P., Calcada, A., Carvalho, N., Serodio, C., Couto, P., Matias, J., Melo-Pinto, P., Morais, J. (2013) Low-cost ultrasonic probe to assess wood defects and parameters. In: Proceedings of the World Congress on Engineering, London, pp. 993–998.
31. Muller, W. (2003) Timber girder inspection using ground penetrating radar. In: International Symposium Non-Destructive Testing in Civil Engineering. DGZfP, Berlin.10.1784/insi.45.12.809.52990 ↗
32. Niemz, P. Zerstörungsfreie Prüfung von Holz und Holzwerkstoffen. Institute for Building Materials, Zürich, 2010.
33. Niemz, P., Mannes, D. (2012) Non-destructive testing of wood and wood-based materials. J. Cult. Herit. 13:26–34.
34. Nowak, T., Hamrol-Bielecka, K., Jasieńko, J. (2015) Non-destructive testing of wood – correlation of ultrasonic and stress wave test results in glued laminated timber members. For Wood Technol. 92:317–324.
35. Nowak, T.P., Jasienko, J., Hamrol-Bielecka, K. (2016) In situ assessment of structural timber using the resistance drilling method – evaluation of usefulness. Constr. Build. Mater. 102:403–415.
36. Nusser, E. Die Bestimmung der Holzfeuchte durch Messung des elektrischen Widerstandes. Dissertation, Technische Hochschule Stuttgart, 1936.
37. Osterloh, K., Hasenstab, A., Zscherpel, U., Alekseychuk, O., Meinel, D., Goebbels, J., Ewert, U. Radiographic and Tomographic Testing of Wood. In EC NDT, Berlin, 2006, pp. 1–10.
38. Piirto, D.D., Wilcox, W.W. (1978) Critical evaluation of the pulsed-current resistance meter for detection of decay in wood. Forest Prod. J. 28:52–56.
39. Riggio, M., Sandak, J., Franke, S. (2015) Application of imaging techniques for detection of defects, damage and decay in timber structures on-site. Constr. Build. Mater. 101:1241–1252.
40. Rinn, F. (2003) Technische Grundlagen mechanischer Impuls-Tomographie an Bäumen. Baumzeitung 8:29–31.
41. Ross, R.J. Nondestructive Testing of Wood. Forest Products Laboratory, Madison, 1992, pp. 43–47.
42. Sanabria, S.J., Mueller, C., Neuenschwander, J., Niemz, P., Sennhauser, U. (2011) Air-coupled ultrasound as an accurate and reproducible method for bonding assessment of glued timber. Wood Sci. Technol. 45:645–659.
43. Schickert, M., Bonitz, F., Ulanov, A., Müller, B., Ruminski, S.C., Rehpenning, P.-E., Blüthgen, L., Flade, P., Wiedemann, J. Tomographische Abbildung mit Ultraschall, Radar und Röntgen zur Detektion von Fäule in Holzstämmen. In DGZfP Jahrestagung. Koblenz, Germany, 2017.
44. Schmoldt, D.L., Nelson, R.M., Ross, R.J., McDonald, K.A. Ultrasonic Inspection of Wooden Pallet Parts Using Time of Flight. Vol. 16. Springer, Boston, 1997.10.1007/978-1-4615-5947-4_234 ↗
45. Shevaldykin, V.G., Samokrutov, A.A., Kozlov, V.N. (2003) Ultrasonic low-frequency short-pulse transducers with dry point contact. Development and application. In: Non-Destructive Testing in Civil Engineering 2003, Ed. DGZfP. International Symposium (NDT-CE 2003), Berlin.
46. Solodov, I., Busse, G. New Advances in Air-Coupled Ultrasonic NDT Using Acoustic Mode Conversion. In EC NDT, Berlin, 2006.
47. Sousa, H.S., Sorensen, J.D., Kirkegaard, P.H., Branco, J.M., Lourenco, P.B. (2013) On the use of NDT data for reliability-based assessment of existing timber structures. Eng. Struct. 56:298–311.
48. Tallavo, F., Cascante, G., Pandey, M.D. (2012) A novel methodology for condition assessment of wood poles using ultrasonic testing. NDT and E Int. 52:149–156.10.1016/j.ndteint.2012.08.002 ↗
49. Tanasoiu, V., Miclea, C., Tanasoiu, C. (2002) Nondestructive testing techniques and piezoelectric ultrasonics transducers for wood and built in wooden structures. J. Optoelectron. Adv. M. 4:949–957.
50. Wang, X., Allison, B. (2008) Decay detection in red oak trees using a combination of visual inspection, acoustic testing, and resistance microdrilling. Arboric. Urban For. 34:1–4.
51. Wang, X., Divos, F., Pilon, C., Brashaw, B.K., Ross, R.J., Pellerin, R.F. Assessment of Decay in Standing Timber Using Stress Wave Timing Nondestructive Evaluation Tools – A Guide for Use and Interpretation. In GeneralTechnicalReport. United States Department of Agriculture, Wisconsin, 2004.10.2737/FPL-GTR-147 ↗
52. Wedvik, B., Stein, M., Stornes, J., Mattsson, J. (2016) On-site radioscopic qualitative assessment of historic timber structures: identification and mapping of biological deterioration of wood. Int. J. Archit. Herit. 10:646–662.10.1080/15583058.2015.1077905 ↗
53. Weihs, U., Krummheuer, F. (1999) Zerstörungsfreie Baumdiagnose mittels elektrischer Widerstandstomographie. Forst. und Holz. 54:166–170.
54. White, R.H., Ross, R.J. Wood and Timber Condition Assessment Manual. In General Technical Report: United States Department of Agriculture, Madison, USA, 2014.
55. Xu, H., Wang, L. (2014) Analysis of cold temperature effect on stress wave velocity in green wood. Holzforschung 68:693–698.10.1515/hf-2013-0151 ↗
56. Yang, Z., Jiang, Z., Hse, C.Y., Liu, R. (2017) Assessing the impact of wood decay fungi on the modulus of elasticity of slash pine (Pinus elliottii) by stress wave non-destructive testing. Int. Biodet. Biodegrad. 117:123–127.10.1016/j.ibiod.2016.12.003 ↗