journal article·2022-11Open access

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

David Miller, Greg Perrin, Kent Terwilliger, Joshua Morse, Chuanxiao Xiao, Bobby To, Sona Ulicna, Chun-Sheng Jiang, Laura T. Schelhas, Peter Hacke

IEEE Journal of Photovoltaics· Volume 12· Issue 6

Abstract

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ∼30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (∼100 °C from ∼40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrical Fault Detection and Protection · Risk and Safety Analysis · Reliability and Maintenance Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

National Renewable Energy Laboratory, Golden, CO, USA

SLAC National Accelerator Laboratory, Menlo Park, CA, USA

Funding

Durable Module Materials Consortium · Energy Materials Network Consortium · U.S. Department of Energy

References (14)

Show source-provided references
1. Evaluating the durability of balance of systems components using C-AST
2. 2022
3. 2022
4. 0
5. 10.1016/B978-0-12-811545-9.00009-410.1016/B978-0-12-811545-9.00009-4 ↗
6. Connectors for DC-Application in Photovoltaic Systems – Safety Requirements and Tests · 2014
7. PV fires experiences in Italy: From forensic activities to fire risk assessment of existing and new PV plants
8. 10.1109/PVSC.2018.854733510.1109/PVSC.2018.8547335 ↗
9. Connectors for Use in Photovoltaic Systems · 2017
10. 10.1109/PVSC48317.2022.993858110.1109/PVSC48317.2022.9938581 ↗
11. Evaluating the durability of balance of systems components using C-AST
12. BoS module reliability
13. Reliability model development for photovoltaic connector lifetime
14. Evaluating the durability of balance of systems components using C-AST