journal article·2022-11

A Robust Islanding Detection Method for Inverter-Based Distributed Generation Systems Using DC-Link Voltage Perturbation

Marcos V. G. dos Reis, Dante I. Narvaez, Hugo S. Moreira, Joao L. de S. Silva, Tarcio A. S. Barros, Marcelo G. Villalva

IEEE Journal of Photovoltaics· Volume 12· Issue 6
Publisher page

Abstract

High penetration of photovoltaic (PV) inverters in the utility grid is happening in several countries. PV inverters must be able to detect the utility grid disconnection and interrupt the injection of active power. This scenario is known as unintentional islanding. However, islanding detection methods (IDM) are still subject to improvement, especially when considering the high penetration of inverters, making vulnerable IDMs not made for this case. Thus, the purpose of this article is to present a new IDM using dc-link voltage perturbation. The proposed method was defined through an algorithm, and its feasibility was tested through simulations and on an experimental setup with multiple inverters. Several scenarios were analyzed, in which the presented method was able to detect grid disconnections, while other methods failed in multiple inverter scenarios. As a result, the method has proven to be robust, even in the presence of several PV inverters connected at the same point. Furthermore, its implementation is easy and can be included in the inverter control firmware, without requiring any additional hardware.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Islanding Detection in Power Systems · Photovoltaic System Optimization Techniques · Microgrid Control and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil

DSE, UNICAMP, Campinas, Brazil

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior · CNPQ · Fundação de Amparo à Pesquisa do Estado de São Paulo · BYD Energy Brazil

References (20)

Show source-provided references
1. A two-stage PV grid-connected inverter with optimized anti-islanding protection method
2. 10.1016/j.solener.2016.08.05110.1016/j.solener.2016.08.051 ↗
3. 10.1109/TEC.2007.91430810.1109/TEC.2007.914308 ↗
4. 10.1109/COBEP.2009.534768210.1109/COBEP.2009.5347682 ↗
5. 10.1109/TPEL.2017.272454410.1109/TPEL.2017.2724544 ↗
6. 10.1109/TSTE.2012.220229410.1109/TSTE.2012.2202294 ↗
7. 10.1109/TIE.2006.88552610.1109/TIE.2006.885526 ↗
8. 10.1109/IECON.2017.821672610.1109/IECON.2017.8216726 ↗
9. 10.1109/IFEEC.2017.799242310.1109/IFEEC.2017.7992423 ↗
10. 10.1109/JPHOTOV.2012.220287910.1109/JPHOTOV.2012.2202879 ↗
11. 10.1109/ECCE.2017.809681010.1109/ECCE.2017.8096810 ↗
12. 10.1109/SPICES.2017.809127210.1109/SPICES.2017.8091272 ↗
13. rodriguez · Grid Converters for Photovoltaic and Wind Power Systems · 2011
14. 10.1016/j.aej.2016.12.02010.1016/j.aej.2016.12.020 ↗
15. 10.1109/TEC.2005.85998110.1109/TEC.2005.859981 ↗
16. 10.1109/TPEL.2016.264675110.1109/TPEL.2016.2646751 ↗
17. 10.1109/TPWRD.2007.91118810.1109/TPWRD.2007.911188 ↗
18. 10.1109/TPWRD.2020.297673910.1109/TPWRD.2020.2976739 ↗
19. 10.1109/TPWRD.2010.209354310.1109/TPWRD.2010.2093543 ↗
20. 10.1109/TEC.2008.200320610.1109/TEC.2008.2003206 ↗