Simulation and Experimental Study on Temperature Rise Characteristic of a Piercing Connector
Source abstract
Abstract
Piercing connectors are among the most used equipment in electric circuit. With the continuous development of the electricity industry, higher requirements for the reliability and heat resistance of the piercing connectors are needed. Aiming at the problems of poor current carrying capacity and heat dissipation status, a multifield coupling model of the piercing connector is created to analyze the structural stress and deformation distribution under the action of preload from the bolt and simulate the temperature distribution under different current intensities and surface roughness. Meanwhile, the measured experiments of contact resistance and highest temperature are performed to explore the relationship between contact resistance and the highest temperature. Results show that the maximum stress of the piercing connector is in the contact region between the piercing blade and the wire, which may be the origin of strength failure. The greater the current intensity and surface roughness, the more obvious the temperature rise. The effect of the different specification combinations of power wire and branch wire on contact resistance is small. Moreover, a critical installation torque exists in the influence range. The experimentally measured temperature verifies that the simulation has high precision. In this article, the numerically calculated and experimentally measured results provide a theoretical basis for optimizing the manufacturing and service performance of the piercing connectors.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrical Contact Performance and Analysis · Adhesion, Friction, and Surface Interactions · Mechanical stress and fatigue analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical Engineering, Hefei University of Technology, Hefei, China
Electric Power Research Institute, State Grid Anhui Electric Power Company Ltd., Hefei, China
Funding
Science and Technology Project of State Grid Corporation of China
References (28)
Show source-provided references
1. 10.1109/HOLM.2019.892394110.1109/HOLM.2019.8923941 ↗
2. Temperature rise calculation and overheating fault analysis of gas-insulated switchgear bus connector based on coupled field theory
3. Finite element analysis of contact temperature rise in gas-insulated busbars based on coupled multi-physics
4. 10.1109/TCPMT.2019.291489410.1109/TCPMT.2019.2914894 ↗
5. 10.1109/TCAPT.2007.90628810.1109/TCAPT.2007.906288 ↗
6. Thermal-electric-structure coupling finite element analysis and experimental study of AgNi10 contact material under the closed contact stage
7. ANSYS Help 15 0 · 2013
8. 10.1016/j.compfluid.2016.09.01810.1016/j.compfluid.2016.09.018 ↗
9. 10.1016/j.commatsci.2009.05.02010.1016/j.commatsci.2009.05.020 ↗
10. 10.1016/j.ijheatmasstransfer.2016.05.02310.1016/j.ijheatmasstransfer.2016.05.023 ↗
11. Insulation Piercing Connector System · 2012 · 64 · 21
12. 10.1016/S0026-2692(02)00053-810.1016/S0026-2692(02)00053-8 ↗
13. 10.1016/j.ijepes.2016.07.00210.1016/j.ijepes.2016.07.002 ↗
14. 10.37394/232012.2020.15.1010.37394/232012.2020.15.10 ↗
15. The finite-element model and analysis of static contact resistance and thermal process for contact with film
16. 10.1109/TCHMT.1982.113592310.1109/TCHMT.1982.1135923 ↗
17. 10.1109/HOLM.2010.561951510.1109/HOLM.2010.5619515 ↗
18. Finite element model analysis of thermal failure in connector10.1631/jzus.2007.A0397 ↗
19. 10.1109/TCPMT.2020.298220710.1109/TCPMT.2020.2982207 ↗
20. 10.1016/j.ijheatmasstransfer.2018.08.13710.1016/j.ijheatmasstransfer.2018.08.137 ↗
21. 10.1103/PhysRevLett.118.20720110.1103/PhysRevLett.118.207201 ↗
22. 10.1007/s00170-018-1593-x10.1007/s00170-018-1593-x ↗
23. liu · Equivalent method of finite element thermal analysis of contact resistance between ground wire and pre-twisted wire · 2018
24. 10.1016/j.ijheatmasstransfer.2021.12124310.1016/j.ijheatmasstransfer.2021.121243 ↗
25. 10.1016/j.triboint.2019.02.03910.1016/j.triboint.2019.02.039 ↗
26. guo · Electrical Contacts Theory and Technology Application · 2008 · 8
27. 10.1109/JMEMS.2005.85665310.1109/JMEMS.2005.856653 ↗
28. 10.1016/j.triboint.2021.10700710.1016/j.triboint.2021.107007 ↗