The Effect of Cable Section on the Variation of Power Automotive Connector Temperature
Source abstract
Abstract
Electric car requires more electric power. However, the automotive connector that is used to connect two electrical systems should resist the high electric power or electric current. The increase in electric current can lead to an increase in contact temperature by the Joule effect and can cause more damage to an improperly designed connector. The objective of this work is to study experimentally and numerically the influence of cable section on the connector capacity to pass high current. Thus, to study this phenomenon, a finite-element model of power automotive connector with cables and crimping zones was developed to calculate contact resistance and contact temperature. The comparison between the experimental and numerical results shows a good agreement for all tested electric currents. The obtained results lead us to use only the developed numerical model to estimate the value of contact resistance and contact temperature for different cable sections. Moreover, the developed model is beneficial financially. Finally, results have illustrated that the effect of the cable section on the decrease in contact temperature and contact resistance is not negligible.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrical Contact Performance and Analysis · Adhesion, Friction, and Surface Interactions · Electronic Packaging and Soldering Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. 10.1016/j.jpowsour.2008.03.06910.1016/j.jpowsour.2008.03.069 ↗
2. High current AC break arc contact erosion
3. 10.1109/HOLM.2013.665143110.1109/HOLM.2013.6651431 ↗
4. 10.1109/HOLM.2016.778001510.1109/HOLM.2016.7780015 ↗
5. 10.1109/ICEPT.2014.692284610.1109/ICEPT.2014.6922846 ↗
6. 10.1109/HOLM.2006.28407110.1109/HOLM.2006.284071 ↗
7. 10.1115/1.400471310.1115/1.4004713 ↗
8. 10.1049/cp.2012.061310.1049/cp.2012.0613 ↗
9. 10.1049/cp.2012.061410.1049/cp.2012.0614 ↗
10. Contact resistance and overtemperature behavior of new and pre-arced power engineering contacts as a function of ambient temperature and contact force
11. 10.1109/HOLM.2014.703102210.1109/HOLM.2014.7031022 ↗
12. 10.1177/095440701876414610.1177/0954407018764146 ↗
13. Finite element model analysis of thermal failure in connector10.1631/jzus.2007.A0397 ↗
14. cao · Heat Transfer in Process Engineering · 2010
15. 10.1109/33.23794310.1109/33.237943 ↗
16. slade · Electrical Contacts Principles and Applications · 2014
17. 10.1016/j.commatsci.2009.05.02010.1016/j.commatsci.2009.05.020 ↗
18. slade · The Vacuum Interrupter Theory Design and Application · 2008
19. 10.1063/1.32318110.1063/1.323181 ↗
20. 10.1007/978-3-662-06688-110.1007/978-3-662-06688-1 ↗
21. merl · Data Book of Electrical Contacts · 2012
22. 10.1587/transele.E93.C.138010.1587/transele.E93.C.1380 ↗
23. 10.1109/HOLM.2014.703104210.1109/HOLM.2014.7031042 ↗
24. Precipitation hardened high copper alloys for connector pins made of wire
25. 10.1243/09544070JAUTO79910.1243/09544070JAUTO799 ↗
26. Company Wieland-Kupferwerkstoffe Gruppe · 1999
27. Rolled Product Properties of Pure Copper · 2014
28. 10.1016/j.msea.2015.02.07310.1016/j.msea.2015.02.073 ↗
29. Finite element software · 2015
30. 10.1557/JMR.2000.004310.1557/JMR.2000.0043 ↗