journal article·2014-02

Double-Loop Thermosyphon for Electric Components Cooling

Francesco Agostini, Mathieu Habert, Francoise Molitor, Reto Flueckiger, Lilian Kaufmann, Alessio Bergamini, Marco Rossi, Stefano Besana

Publisher page

Abstract

A double-loop thermosyphon for cooling electric components is presented. It consists of two loop thermosyphons in series, both driven by gravity. The evaporator of the first loop is in contact with the heating blocks providing the power. The condenser of the first loop thermosyphon comprises a heat exchanger plate, in close contact with a second heat exchanger plate serving as evaporator for the second loop. The heat is finally removed from the condenser of the second loop by forced convection. The motivation behind this double-loop thermosyphon consisting of two thermosyphons in series is increased layout flexibility. The thermal performance of the system is presented and compared with simulations based on a 1-D numerical model.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Heat Transfer and Boiling Studies · Heat Transfer and Optimization · Refrigeration and Air Conditioning Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. 10.1016/j.applthermaleng.2003.12.00410.1016/j.applthermaleng.2003.12.004 ↗
2. 10.1016/j.ijheatmasstransfer.2008.06.01610.1016/j.ijheatmasstransfer.2008.06.016 ↗
3. 10.1109/95.46515810.1109/95.465158 ↗
5. Two-phase loop thermosyphons
6. 10.1109/TCAPT.2003.81147810.1109/TCAPT.2003.811478 ↗
7. 10.1002/(SICI)1523-149X(1999)28:8<627::AID-HTJ1>3.3.CO;2-K10.1002/(SICI)1523-149X(1999)28:8<627::AID-HTJ1>3.3.CO;2-K ↗
8. 10.1002/(SICI)1523-1496(200005)29:3<204::AID-HTJ5>3.0.CO;2-M10.1002/(SICI)1523-1496(200005)29:3<204::AID-HTJ5>3.0.CO;2-M ↗
9. 10.1115/ICNMM2008-6207810.1115/ICNMM2008-62078 ↗
10. Non-intrusive measurement of the mass flow rate inside a closed loop two-phase thermosyphon
11. 10.1109/ITHERM.2012.623154410.1109/ITHERM.2012.6231544 ↗
12. Performance of a gravity-driven and capillary-sized thermosyphon loop working with ammonia
13. 10.1109/STHERM.1999.76242110.1109/STHERM.1999.762421 ↗
14. 10.1109/EPTC.1998.75599410.1109/EPTC.1998.755994 ↗
15. 10.1109/THETA.2008.516718410.1109/THETA.2008.5167184 ↗
16. 10.1109/TCAPT.2002.80799710.1109/TCAPT.2002.807997 ↗
17. Compact thermosyphon heat exchanger for power electronics cooling
18. 10.1109/INTLEC.2011.609977310.1109/INTLEC.2011.6099773 ↗
19. 10.1016/S1359-4311(97)00005-710.1016/S1359-4311(97)00005-7 ↗
20. 10.2495/HT10020110.2495/HT100201 ↗