The Case for Containment
Source abstract
Abstract
Air-cooled data centers still represent the majority of all data centers. This paper discusses the fundamental aspect of improving efficiency in these data centers, namely, airflow management. At the room and row level, containment systems offer many benefits for reducing computer room air handler fan power, as well as cooling system overhead. This paper explores the history of the development as well as current code and policy issues affecting the use or need of containment systems. Specific efficiency gains are cited, and extensive discussion of practical aspects of containment systems is given.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fluid dynamics and aerodynamics studies · Computational Physics and Python Applications · Heat Transfer and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Fall 2009 Data Center Users’ Group Survey Results · 2009
2. 10.1115/IPACK2011-5209010.1115/IPACK2011-52090 ↗
3. Experimental evaluation of the plenum concept for data center air cooling
4. 10.1109/UPEC.2015.733990010.1109/UPEC.2015.7339900 ↗
5. 10.1109/EIDWT.2013.12510.1109/EIDWT.2013.125 ↗
6. 10.1109/SEMI-THERM.2013.652683310.1109/SEMI-THERM.2013.6526833 ↗
7. 10.1109/ICIAFS.2014.706963310.1109/ICIAFS.2014.7069633 ↗
8. 10.1109/ITHERM.2008.454440310.1109/ITHERM.2008.4544403 ↗
9. 10.1115/InterPACK2009-8920310.1115/InterPACK2009-89203 ↗
10. 10.1115/IPACK2011-5220610.1115/IPACK2011-52206 ↗
11. 2008 ASHRAE environmental guidelines for datacom equipment: Expanding the recommended environmental envelope
12. DataCenter2020: The infrastructure test lab, data center management and efficiency at its best
13. Evolution of data center environmental guidelines
14. Best Practice Guidelines for the EU Code of Conduct on Data Centre Energy Efficiency Version 7 1 2 · 2016
15. 2011 Thermal guidelines for data processing environments—Expanded data center classes and usage guidance
16. Data center optimization initiative department of energy
17. ASHRAE ANSI/ASHRAE Energy Standard for Data Centers · 2016
18. Mission Critical Facilities Data Centers Technology Spaces and Electronic Equipment Technical Committee 9 9 · 2016
19. Fall 2014 Data Center Users’ Group Survey Results · 2014
20. California's energy efficiency standards for residential and nonresidential buildings · 2013
21. 10.1109/ITHERM.2012.623141510.1109/ITHERM.2012.6231415 ↗
22. 10.1109/ITHERM.2016.751771710.1109/ITHERM.2016.7517717 ↗
23. 10.1109/INTLEC.2008.466404710.1109/INTLEC.2008.4664047 ↗
24. 10.1109/ITHERM.2014.689240810.1109/ITHERM.2014.6892408 ↗
25. 10.1115/IPACK2013-7316310.1115/IPACK2013-73163 ↗
26. Data center 2020: Delivering high density in the data center; efficiently and reliably
27. 10.1109/SECON.2013.656736110.1109/SECON.2013.6567361 ↗