Computational and Experimental Investigation of Thermal Coupling Between Superlattice Coolers
Source abstract
Abstract
Thermal coupling between superlattice coolers (SLCs) in an array adversely affects performance of an each individual cooler compared with an isolated device. Here, we have developed an electrothermal model to study this coupling between SLCs and how it is affected by geometric parameters such as separation between the superlattice structure and a ground electrode, and operating parameters such as the convective heat transfer coefficient and the activation current applied for driving the SLC. Complementary to the modeling efforts, we have also experimentally studied thermal coupling between SLCs in a microfabricated array under various conditions. Simulation results are critically compared against the experimental data and yield the conclusions of importance for an optimized design of the hybrid microfluidic SLC cooling scheme for thermal management of multiple clustered hotspots in microprocessors. We have observed more than 60% reduction in cooler performance, when placed within the few characteristic diameters of the ground electrode, due to thermal coupling effect. Thermal properties of the working fluid have even more pronounced effect on the thermal coupling between the coolers.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Heat Transfer and Optimization · Advanced Thermoelectric Materials and Devices · Thermal properties of materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. 10.1109/JPROC.2006.87978710.1109/JPROC.2006.879787 ↗
2. 10.1109/TCAPT.2006.88050810.1109/TCAPT.2006.880508 ↗
3. 10.1557/mrs2006.4710.1557/mrs2006.47 ↗
4. 10.1038/nnano.2008.41710.1038/nnano.2008.417 ↗
5. 10.1109/ICT.2001.97991510.1109/ICT.2001.979915 ↗
6. SiGeC cantilever micro cooler
7. 10.1109/33.18004910.1109/33.180049 ↗
8. 10.1063/1.173586910.1063/1.1735869 ↗
9. 10.1109/TCAPT.2006.88050810.1109/TCAPT.2006.880508 ↗
10. 10.1016/S0017-9310(97)00096-310.1016/S0017-9310(97)00096-3 ↗
11. 10.1080/0145763059100365510.1080/01457630591003655 ↗
12. 10.1016/0017-9310(95)00216-210.1016/0017-9310(95)00216-2 ↗
13. Prandtl-number effects and generalized correlations for confined and submerged jet impingement10.1016/S0017-9310(01)00003-5 ↗
14. 10.1109/ITHERM.2010.550125510.1109/ITHERM.2010.5501255 ↗
15. 10.1109/ITHERM.2004.131835810.1109/ITHERM.2004.1318358 ↗
16. 10.1109/TCAPT.2007.89797710.1109/TCAPT.2007.897977 ↗
17. International Technology Roadmap for Semiconductors · 2005
18. Experimental characterization of hybrid solid-state and fluidic cooling for thermal management of localized hotspots