Novel Formulation of Mixed-Mode S-Parameters
Source abstract
Abstract
In this paper, we present a new formulation for the conversion of mixed-mode S-parameters from single-ended S-parameter results. The formulation can be used to improve the accuracy of the characterization of mixed-mode S-parameters including the measurement of differential insertion loss S-parameters (S DD21 ) for transmission lines. The formulation can also be used to reduce the length of test structures or coupons with an acceptable rate of accuracy. The formulation is an explicit expression, which is also useful as a basis for other derivations and applications. For example, the single-ended transmission to differential insertion loss (SET2DIL) formula can be simply derived from the S DD21 term. The applications to coupled microstrips and striplines are illustrated. The method is compared to time-domain methods for S DD21 characterization. Simulation and measurement results are shown to validate the method.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electromagnetic Compatibility and Noise Suppression · Electromagnetic Compatibility and Measurements · Microwave and Dielectric Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. 10.1109/TEMC.2006.87936010.1109/TEMC.2006.879360 ↗
2. 10.1109/TEMC.2006.87935810.1109/TEMC.2006.879358 ↗
3. 10.2528/PIER1507260510.2528/PIER15072605 ↗
4. Broadband Green’s function and applications to fast electromagnetic modeling of high speed interconnects
5. 10.1109/TMTT.1965.112596410.1109/TMTT.1965.1125964 ↗
6. 10.1109/22.39291110.1109/22.392911 ↗
7. 10.1109/22.59844310.1109/22.598443 ↗
8. SET2DIL: Method to derive differential insertion loss from single-ended TDR/TDT measurements
9. Method to reduce coupon lengths for transmission line S-parameter measurements through elimination of guided-wave multiple reflections
10. Method to reduce coupon length for S-parameter measurements
11. 10.1109/96.61821710.1109/96.618217 ↗
12. 10.1109/22.74008910.1109/22.740089 ↗
13. 10.1109/TCPMT.2017.267270010.1109/TCPMT.2017.2672700 ↗
14. 10.1109/TCPMT.2017.265738010.1109/TCPMT.2017.2657380 ↗
15. 10.1109/TCPMT.2017.266106510.1109/TCPMT.2017.2661065 ↗
16. 10.1109/TCPMT.2017.269698110.1109/TCPMT.2017.2696981 ↗
17. 10.1109/TEMC.2017.272795810.1109/TEMC.2017.2727958 ↗
18. 2008
19. 10.2528/PIERB1704160510.2528/PIERB17041605 ↗
20. 10.2528/PIERB1511060310.2528/PIERB15110603 ↗
21. 10.1109/TEMC.2016.256558410.1109/TEMC.2016.2565584 ↗
22. 10.1109/TCPMT.2016.258238510.1109/TCPMT.2016.2582385 ↗
23. 10.2528/PIERB1511060210.2528/PIERB15110602 ↗
24. 10.1109/TEMC.2016.258286710.1109/TEMC.2016.2582867 ↗
25. 10.1109/TCPMT.2012.221089110.1109/TCPMT.2012.2210891 ↗
26. 10.1109/EUMC.2007.440517010.1109/EUMC.2007.4405170 ↗
27. 10.1109/TMTT.2005.86049710.1109/TMTT.2005.860497 ↗
28. 10.1109/SaPIW.2015.723739310.1109/SaPIW.2015.7237393 ↗
29. 10.1109/EMCSI.2015.710770010.1109/EMCSI.2015.7107700 ↗
30. 10.1109/TEMC.2017.266558210.1109/TEMC.2017.2665582 ↗
31. 10.1109/TCPMT.2015.242665610.1109/TCPMT.2015.2426656 ↗