Packaged Ka-Band IPD Bandpass Filter Using In-Phase and Out-of-Phase Mixed Couplings
Source abstract
Abstract
By effectively merging in-phase and out-of-phase electric and magnetic mixed couplings in an inline fourth-order topology, a high-selectivity millimeter-wave bandpass filter (BPF) is proposed. The use of in-phase and out-of-phase mixed couplings introduces pairs of 180° phase shift, resulting in multiple transmission zeros (TZs) generated outside the passband, whose locations can be independently controlled by adjusting the coupling strength. Furthermore, the equivalent circuit models are analyzed and discussed to elucidate the operating mechanism. For experimental verification, a 25 GHz in-line fourth-order high-selectivity BPF is designed and fabricated using gallium arsenide (GaAs)-based integrated passive device (IPD) process. Compared to prior works, the proposed BPF shows the merits of high selectivity, wider rejection bandwidth, and low insertion losses, making it well-suited for enhancing receiver sensitivity and suppressing interference in satellite communication systems.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Microwave Engineering and Waveguides · Semiconductor Lasers and Optical Devices · Radio Frequency Integrated Circuit Design
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz, School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
Funding
National Natural Science Foundation of China · Natural Science Foundation of Jiangsu Province for Youth
References (27)
Show source-provided references
1. 10.1109/TEMC.2017.269045710.1109/TEMC.2017.2690457 ↗
2. 10.1109/TMTT.2021.307332110.1109/TMTT.2021.3073321 ↗
3. 10.1109/TCSII.2017.278269210.1109/TCSII.2017.2782692 ↗
4. 10.1109/TCPMT.2024.342478310.1109/TCPMT.2024.3424783 ↗
5. 10.1109/TCPMT.2024.342011210.1109/TCPMT.2024.3420112 ↗
6. 10.1109/TCPMT.2023.331963510.1109/TCPMT.2023.3319635 ↗
7. 10.1109/TCPMT.2024.340943410.1109/TCPMT.2024.3409434 ↗
8. 10.1109/TCPMT.2023.332818710.1109/TCPMT.2023.3328187 ↗
9. 10.1109/TCPMT.2014.234624010.1109/TCPMT.2014.2346240 ↗
10. 10.1109/TMTT.2005.86411810.1109/TMTT.2005.864118 ↗
11. 10.1109/TMTT.2015.246738010.1109/TMTT.2015.2467380 ↗
12. 10.1109/TMTT.2019.295358510.1109/TMTT.2019.2953585 ↗
13. 10.1109/TMTT.2022.322544710.1109/TMTT.2022.3225447 ↗
14. 10.1109/TCSII.2023.332019410.1109/TCSII.2023.3320194 ↗
15. 10.1109/tcpmt.2025.355741110.1109/tcpmt.2025.3557411 ↗
16. 10.1109/mwsym.2014.684860810.1109/mwsym.2014.6848608 ↗
17. 10.1049/el.2011.070310.1049/el.2011.0703 ↗
18. 10.1109/ACCESS.2019.293176510.1109/ACCESS.2019.2931765 ↗
19. 10.1109/TCSII.2019.292923110.1109/TCSII.2019.2929231 ↗
20. 10.1109/TCSII.2022.318618210.1109/TCSII.2022.3186182 ↗
21. 10.1109/TCSII.2021.307815410.1109/TCSII.2021.3078154 ↗
22. 10.1002/047122161910.1002/0471221619 ↗
23. 10.1109/TMTT.2002.80693710.1109/TMTT.2002.806937 ↗
24. 10.1109/TMTT.2022.322076110.1109/TMTT.2022.3220761 ↗
25. 10.1002/mop.3413410.1002/mop.34134 ↗
26. 10.1109/TMTT.2023.331635810.1109/TMTT.2023.3316358 ↗
27. 10.1109/LED.2021.313962310.1109/LED.2021.3139623 ↗