A New Asymmetric Calibration Method for Characterizing Four-Component Electromagnetic Probe
Source abstract
Abstract
In this work, for the four-port electromagnetic probe capable of simultaneously measuring four different electric and magnetic fields (Hy, Ez, Hz and Ey), the asymmetry in the transmission path may lead to deviations in the near-field measurement results. In order to effectively alleviate the deviations, a new asymmetric calibration method (ACM) is proposed in the work. By combining rotating and non-rotating asymmetric calibration techniques, ACM can be used for precisely calibrating the four-port electromagnetic probe with a pair of male-to-female adapters. A self-developed near-field measurement system with two different calibration kits is used to verify the rationality of the ACM on the four-port electromagnetic probe. In these calibration kits, a 50Ω grounded coplanar waveguide (GCPW) is utilized to generate the desired electric and magnetic fields (Ez, and Hy), while a 50Ω slot-line (SL) is used to excite the desired electric and magnetic fields (Hz, and Ey). As a result, the effectiveness of the ACM can be validated by combining the measured calibration factors (CFs) and standing wave experiments.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electromagnetic Compatibility and Measurements · Microwave and Dielectric Measurement Techniques · Advanced Electrical Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electronic Information and Artificial Intelligence, Shaanxi University of Science and Technology, Xi’an, China
National Key Laboratory of Electronic Components Reliability, CEPREI, Guangzhou, China
References (28)
Show source-provided references
1. 10.1109/ITNEC56291.2023.1008195610.1109/ITNEC56291.2023.10081956 ↗
2. 10.1109/IBCAST59916.2023.1071283910.1109/IBCAST59916.2023.10712839 ↗
3. 10.1109/LAWP.2024.341742810.1109/LAWP.2024.3417428 ↗
4. 10.1109/IEEE-IWS.2019.880415010.1109/IEEE-IWS.2019.8804150 ↗
5. 10.1109/EMCEurope59828.2024.1072271310.1109/EMCEurope59828.2024.10722713 ↗
6. 10.1109/emceurope57790.2023.1027426610.1109/emceurope57790.2023.10274266 ↗
7. 10.1109/JSEN.2020.298176410.1109/JSEN.2020.2981764 ↗
8. 10.1109/TMTT.2013.225803410.1109/TMTT.2013.2258034 ↗
9. 10.1109/TIM.2019.292070010.1109/TIM.2019.2920700 ↗
10. 10.1109/TAP.2019.289747610.1109/TAP.2019.2897476 ↗
11. 10.1109/TCSII.2024.335523110.1109/TCSII.2024.3355231 ↗
12. 10.1109/APS/URSI47566.2021.970443610.1109/APS/URSI47566.2021.9704436 ↗
13. 10.1109/LAWP.2023.331052610.1109/LAWP.2023.3310526 ↗
14. 10.1109/LMAG.2023.332451710.1109/LMAG.2023.3324517 ↗
15. 10.1109/MECAP.2016.779010310.1109/MECAP.2016.7790103 ↗
16. 10.1109/TAP.2019.292781410.1109/TAP.2019.2927814 ↗
17. 10.1109/TCPMT.2023.329998110.1109/TCPMT.2023.3299981 ↗
18. 10.1109/JSEN.2024.347256810.1109/JSEN.2024.3472568 ↗
19. 10.1109/ICIT.2010.547267710.1109/ICIT.2010.5472677 ↗
20. 10.1109/lmwt.2025.364752910.1109/lmwt.2025.3647529 ↗
21. 10.1109/TMTT.2021.312014010.1109/TMTT.2021.3120140 ↗
22. 10.1109/TMTT.2022.321484710.1109/TMTT.2022.3214847 ↗
23. 10.1109/TAP.2023.328855910.1109/TAP.2023.3288559 ↗
24. 10.1109/TAP.2023.329905010.1109/TAP.2023.3299050 ↗
25. 10.1109/TAP.2023.334860010.1109/TAP.2023.3348600 ↗
26. 10.1109/jsen.2024.338439910.1109/jsen.2024.3384399 ↗
27. 10.1109/TIM.2024.340320410.1109/TIM.2024.3403204 ↗
28. 10.3403/0283172710.3403/02831727 ↗