journal article·2026-06

Arc Restrike in DC Contactor During Arc Splitting Process Under Inhomogeneous Magnetic Field and Its Evaluation Methodology

Shidong Peng, Jing Li, Yifan Zhao, Zhengbo Li, Shuxin Liu, Si Fu, Chongyang Huang

Publisher page

Abstract

The arc extinguishing performance of existing dc contactors has been challenging to meet the development needs of battery electrical vehicles (BEVs), which is mainly manifested in the frequent arc re-strike when the large-capacity dc contactor is breaking. In this research, the arc re-strike under an inhomogeneous magnetic field was investigated by the numerical model in which the precision was proved by experiment, and the severity of arc re-strike under different copper (Cu) vapor concentrations was evaluated. The thermal re-strike and electrical re-strike can simultaneously simulate in this research, and arc re-strike between the contacts and arc re-strike between the splitter plates was discovered. The results show that increasing the magnetic field is conducive to arc extinction, but increasing the magnetic field above 60 mT has little effect on arc duration. The arc re-strike is become severe when Cu vapor concentration is above 60 %, which is related to the small specific heat at constant pressure Cp and thermal conductivity λ of the mixed gas at high Cu vapor concentration. The magnetic field saturation threshold and arc re-strike evaluation methodology presented in this paper can be used to optimize the configuration of permanent magnets and the geometric dimensions of arc chamber under the premise of meeting the constraints of breaking capacity and arc re-strike risk.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Vacuum and Plasma Arcs · Electrical Contact Performance and Analysis · Railway Systems and Materials Science

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Energy and Electrical Engineering, Hunan Institute of Science and Technology, Yueyang, China

Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China

Lanzhou New Area Power Supply Company, State Grid Gansu Electric Power Company, Lanzhou, China

School of Information Science and Engineering, Shenyang University of Technology, Shenyang, China

Funding

Research Foundation of Education Bureau of Hunan Province · Joint Science and Technology Program of Liaoning Province

References (51)

Show source-provided references
1. 10.1016/j.epsr.2022.10794610.1016/j.epsr.2022.107946 ↗
2. 10.1109/tia.2017.276187010.1109/tia.2017.2761870 ↗
3. 10.1016/j.epsr.2023.10986610.1016/j.epsr.2023.109866 ↗
4. 10.1088/2058-6272/ac71a310.1088/2058-6272/ac71a3 ↗
5. 10.1063/5.025534910.1063/5.0255349 ↗
6. 10.1109/tpwrd.2025.354385510.1109/tpwrd.2025.3543855 ↗
7. Arc root development and its influence on arc reigniting during the breaking process of the DC contactor
8. 10.1109/tcpmt.2019.289178210.1109/tcpmt.2019.2891782 ↗
9. 10.1109/tcpmt.2017.277974110.1109/tcpmt.2017.2779741 ↗
10. 10.1109/tte.2023.326990310.1109/tte.2023.3269903 ↗
11. 10.1109/ciycee49808.2020.933269210.1109/ciycee49808.2020.9332692 ↗
12. 10.1109/tps.2025.354769310.1109/tps.2025.3547693 ↗
13. 10.1016/j.jmapro.2024.07.00610.1016/j.jmapro.2024.07.006 ↗
14. 10.3390/en1323637710.3390/en13236377 ↗
15. 10.1007/s42835-022-01136-w10.1007/s42835-022-01136-w ↗
16. 10.1088/1361-6463/ae32a010.1088/1361-6463/ae32a0 ↗
17. 10.1109/tcpmt.2020.301247010.1109/tcpmt.2020.3012470 ↗
18. 10.1109/tcpmt.2018.281180110.1109/tcpmt.2018.2811801 ↗
19. 10.1109/tps.2020.302259410.1109/tps.2020.3022594 ↗
20. 10.1088/1361-6595/ac8db810.1088/1361-6595/ac8db8 ↗
21. 10.1088/1361-6501/ae264a10.1088/1361-6501/ae264a ↗
22. 10.1088/1361-6463/abc64b10.1088/1361-6463/abc64b ↗
23. 10.1109/tps.2024.346995510.1109/tps.2024.3469955 ↗
24. 10.1109/tim.2025.365029410.1109/tim.2025.3650294 ↗
25. 10.1109/tia.2016.258776010.1109/tia.2016.2587760 ↗
26. 10.1109/tia.2016.259368710.1109/tia.2016.2593687 ↗
27. 10.1109/tcpmt.2026.365435110.1109/tcpmt.2026.3654351 ↗
28. 10.1109/tps.2013.227383210.1109/tps.2013.2273832 ↗
29. 10.1088/2058-6272/ab5ba210.1088/2058-6272/ab5ba2 ↗
30. 10.1063/5.001215910.1063/5.0012159 ↗
31. 10.1088/1361-6595/ab3c7d10.1088/1361-6595/ab3c7d ↗
32. 10.1063/5.025639810.1063/5.0256398 ↗
33. 10.1109/tia.2016.260878710.1109/tia.2016.2608787 ↗
34. 10.1109/holm.2018.861172510.1109/holm.2018.8611725 ↗
35. 10.1088/1361-6463/ad39f810.1088/1361-6463/ad39f8 ↗
36. 10.1007/978-1-4899-1337-110.1007/978-1-4899-1337-1 ↗
37. 10.3390/en1318484610.3390/en13184846 ↗
38. 10.1088/0963-0252/17/3/03501610.1088/0963-0252/17/3/035016 ↗
39. 10.1088/0022-3727/26/11/01310.1088/0022-3727/26/11/013 ↗
40. 10.1109/tps.2016.263340010.1109/tps.2016.2633400 ↗
41. 10.1016/j.ijthermalsci.2025.10991910.1016/j.ijthermalsci.2025.109919 ↗
42. 10.1088/0022-3727/30/5/00910.1088/0022-3727/30/5/009 ↗
43. 10.1088/1361-6463/ab9fc210.1088/1361-6463/ab9fc2 ↗
44. 10.1088/1674-1056/acd7cb10.1088/1674-1056/acd7cb ↗
45. 10.1088/0022-3727/30/14/01110.1088/0022-3727/30/14/011 ↗
46. 10.1088/1361-6595/ac1dee10.1088/1361-6595/ac1dee ↗
47. 10.1063/5.017418410.1063/5.0174184 ↗
48. 10.1063/5.023938910.1063/5.0239389 ↗
49. Research on arc root transition of magnetic DC air circuit breaker and its influence on breaking characteristics
50. Overview of the arc mechanism and extinguishing in the circuit breaker of a more-electric aircraft
51. Study of unexpected electric breakdowns on the grid of ion thruster