journal article·2012-03Open access

Identification of Nonlinear Lateral Flow Immunoassay State-Space Models via Particle Filter Approach

Nianyin Zeng, Zidong Wang, Yurong Li, Min Du, Xiaohui Liu

Abstract

In this paper, the particle filtering approach is used, together with the kernel smoothing method, to identify the state-space model for the lateral flow immunoassay through available but short time-series measurement. The lateral flow immunoassay model is viewed as a nonlinear dynamic stochastic model consisting of the equations for the biochemical reaction system as well as the measurement output. The renowned extended Kalman filter is chosen as the importance density of the particle filter for the purpose of modeling the nonlinear lateral flow immunoassay. By using the developed particle filter, both the states and parameters of the nonlinear state-space model can be identified simultaneously. The identified model is of fundamental significance for the development of lateral flow immunoassay quantification. It is shown that the proposed particle filtering approach works well for modeling the lateral flow immunoassay.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Electrostatics and Colloid Interactions · Water Systems and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. 10.1038/nature0506410.1038/nature05064 ↗
2. 10.1109/TNB.2008.200014910.1109/TNB.2008.2000149 ↗
3. 10.1109/TCBB.2009.510.1109/TCBB.2009.5 ↗
4. 10.1371/journal.pone.000375810.1371/journal.pone.0003758 ↗
5. 10.1109/TBME.2011.210650210.1109/TBME.2011.2106502 ↗
6. 10.1109/78.97837410.1109/78.978374 ↗
7. 10.1109/TBME.2007.91467410.1109/TBME.2007.914674 ↗
8. 10.1016/j.mimet.2010.03.00710.1016/j.mimet.2010.03.007 ↗
9. 10.1109/TBME.2011.210732110.1109/TBME.2011.2107321 ↗
10. Study on the methodology of quantitative gold immunochromatographic strip assay
11. 10.2307/296541010.2307/2965410 ↗
12. 10.3724/SP.J.1146.2007.0027310.3724/SP.J.1146.2007.00273 ↗
13. robert · Monte Carlo Statistical Methods · 199910.1007/978-1-4757-3071-5 ↗
14. 10.1023/A:100893541003810.1023/A:1008935410038 ↗
15. 10.2307/268417010.2307/2684170 ↗
16. raphael · Lateral Flow Immunoassay · 2008
17. Application of photoelectric sensor to quantitative determination of immunochromatographic assay strip
18. 10.1016/j.ab.2003.12.01910.1016/j.ab.2003.12.019 ↗
19. 10.1021/es070194j10.1021/es070194j ↗
20. Developing rapid mobile POC systems. Part I: Devices and applications for lateral-flow immunodiagnostics
21. 10.1007/s00190005023610.1007/s001900050236 ↗
22. 10.1016/j.jprocont.2005.01.00110.1016/j.jprocont.2005.01.001 ↗
23. 10.1016/j.ijleo.2009.04.00410.1016/j.ijleo.2009.04.004 ↗
24. 10.1109/TASL.2010.204212710.1109/TASL.2010.2042127 ↗
25. 10.1007/978-1-4757-3437-9_1010.1007/978-1-4757-3437-9_10 ↗
26. 10.1016/j.bios.2008.11.00410.1016/j.bios.2008.11.004 ↗
27. 10.1007/s00216-006-0549-410.1007/s00216-006-0549-4 ↗
28. 10.2307/229028210.2307/2290282 ↗
29. 10.1007/BF0253050810.1007/BF02530508 ↗
30. 10.1049/ip-f-2.1993.001510.1049/ip-f-2.1993.0015 ↗
31. 0
32. Evaluation of a rapid qualitative prostate specific antigen assay, the one step PSA (TM) test10.1016/S0304-3835(00)00615-7 ↗
33. 10.1016/j.ab.2003.07.01110.1016/j.ab.2003.07.011 ↗
34. ljung · System Identification Theory for the User · 1999