The study proposed simple methods with hydrothermal method and physical vapor deposition coating technique (sputter coater) to prepare Pt nanoparticles attach on ZnO nanorods, and then applied in non-enzymatic glucose sensor. Glucose sensing is tested using electrochemical measurement, including cyclic voltammetry and amperometry method. In cyclic voltammetry measurement, the sensitivity of ZnO and Pt/ZnO NRs sensor are 5.0273 and 32.0527 μA/cm 2 -mM when an applied potential at 0.1V, which is carried out different glucose concentration from 0 mM to 8 mM. For observing the stability and selectivity, we were used the amperometry method to measure various glucose concentration and interfering species (ascorbic acid and uric acid). It is demonstrated that the Pt/ZnO NRs sensor exhibited excellent stability and anti-interference performance.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advanced Nanomaterials in Catalysis · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering, Institute of Microelectronics, National Cheng Kung University, Tainan, Taiwan
Department of Electronic Engineering, National United University, Miaoli City, Taiwan
Department of Electronic Engineering, National Formosa University, Yunlin City, Taiwan
Department of Electrical Engineering, Institute of Microelectronics, National Cheng Kung University, Tainan City, Taiwan
Funding
Ministry of Science and Technology
References (46)
Show source-provided references
1. Williams · 2019 · 4
2. 10.1016/j.snb.2017.07.00810.1016/j.snb.2017.07.008 ↗
3. 10.3390/s803140010.3390/s8031400 ↗
4. 10.1111/j.1749-6632.1962.tb13623.x10.1111/j.1749-6632.1962.tb13623.x ↗
5. 10.1016/j.msec.2018.04.03910.1016/j.msec.2018.04.039 ↗
6. 10.1016/j.bios.2005.09.01410.1016/j.bios.2005.09.014 ↗
7. 10.1021/ac026346510.1021/ac0263465 ↗
8. 10.1016/j.bios.2009.04.04510.1016/j.bios.2009.04.045 ↗
9. 10.1016/j.bios.2009.04.03210.1016/j.bios.2009.04.032 ↗
10. 10.1016/j.aca.2011.10.02510.1016/j.aca.2011.10.025 ↗
11. 10.1039/C1RA00641J10.1039/C1RA00641J ↗
12. 10.1021/nn300097q10.1021/nn300097q ↗
13. 10.1039/C6TB02037B10.1039/C6TB02037B ↗
14. 10.1063/1.199266610.1063/1.1992666 ↗
15. 10.1088/1468-6996/10/1/01300110.1088/1468-6996/10/1/013001 ↗
16. 10.1039/c2jm15548f10.1039/c2jm15548f ↗
17. 10.1016/j.electacta.2013.05.14610.1016/j.electacta.2013.05.146 ↗
18. 10.1049/mnl.2012.062210.1049/mnl.2012.0622 ↗
19. 10.1016/j.snb.2014.11.09110.1016/j.snb.2014.11.091 ↗
20. 10.1039/C6RA10698F10.1039/C6RA10698F ↗
21. 10.1016/j.electacta.2015.07.09810.1016/j.electacta.2015.07.098 ↗
22. 10.1088/0957-4484/26/37/37550110.1088/0957-4484/26/37/375501 ↗
23. 10.1016/j.electacta.2011.11.08910.1016/j.electacta.2011.11.089 ↗
24. 10.1021/acsami.7b0221710.1021/acsami.7b02217 ↗
25. 10.1109/JSEN.2022.321014210.1109/JSEN.2022.3210142 ↗
26. 10.1109/JSEN.2021.306790610.1109/JSEN.2021.3067906 ↗
27. 10.1016/j.snb.2023.13395210.1016/j.snb.2023.133952 ↗
28. 10.1021/acsami.1c0388410.1021/acsami.1c03884 ↗
29. 10.1149/2.1141802jes10.1149/2.1141802jes ↗
30. 10.1016/j.electacta.2013.12.08210.1016/j.electacta.2013.12.082 ↗
31. 10.1016/j.apsusc.2013.10.06410.1016/j.apsusc.2013.10.064 ↗
32. 10.1039/c6tb02784a10.1039/c6tb02784a ↗
33. 10.1149/2.0051705jes10.1149/2.0051705jes ↗
34. 10.1021/acsaelm.0c0055610.1021/acsaelm.0c00556 ↗
35. 10.1107/S010876818801010910.1107/S0108768188010109 ↗
36. Precision measurements of crystal parameters10.1080/14786443309462199 ↗
37. 10.1063/1.486632210.1063/1.4866322 ↗
38. 10.1039/C6QI00064A10.1039/C6QI00064A ↗
39. 10.1039/D0CE01318H10.1039/D0CE01318H ↗
40. 10.1016/j.jelechem.2018.04.00110.1016/j.jelechem.2018.04.001 ↗
41. 10.1021/la053071q10.1021/la053071q ↗
42. 10.1021/acs.jpcb.6b1125710.1021/acs.jpcb.6b11257 ↗
43. 10.1016/j.electacta.2011.09.08310.1016/j.electacta.2011.09.083 ↗
44. 10.1016/j.electacta.2015.01.08510.1016/j.electacta.2015.01.085 ↗
45. 10.1002/elan.20130028610.1002/elan.201300286 ↗
46. 10.1002/elan.20090063310.1002/elan.200900633 ↗