A High-Stability QCM Humidity Sensor Coated With Nanodiamond/Multiwalled Carbon Nanotubes Nanocomposite
Source abstract
Abstract
In this paper, a high-stability QCM humidity sensor coated with nanodiamond (ND)/multiwalled carbon nanotubes (MWCNTs) nanocomposite film was purposed based on good dispersion of MWCNTs in ND solution. The experimental results demonstrated that the sensor not only had a relative high frequency shift with humidity change, but also maintained a high quality (Q) factor compared with that of pure ND film coated sensor. In high humidity, the Q factor of ND/MWCNTs coated sensor is about four times larger than that of pure ND coated sensor, and can retain negligible change as long as several months. The possible reason was analyzed and discussed. Moreover, the sensor exhibited low hysteresis, fast response/recovery time, and good repeatability.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Analytical Chemistry and Sensors · Carbon Nanotubes in Composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. 10.1021/ie102427610.1021/ie1024276 ↗
2. 10.1016/j.snb.2016.04.07010.1016/j.snb.2016.04.070 ↗
3. 10.1016/0022-0728(92)80085-I10.1016/0022-0728(92)80085-I ↗
4. 10.1016/S0013-4686(00)00451-510.1016/S0013-4686(00)00451-5 ↗
5. 10.1016/j.snb.2014.02.07810.1016/j.snb.2014.02.078 ↗
6. 10.1109/JSEN.2013.227361510.1109/JSEN.2013.2273615 ↗
7. 10.1109/MEMSYS.2008.444359610.1109/MEMSYS.2008.4443596 ↗
8. 10.1016/0925-4005(95)85013-910.1016/0925-4005(95)85013-9 ↗
9. 10.1109/TNANO.2014.230598610.1109/TNANO.2014.2305986 ↗
10. 10.1109/FREQ.2000.88732510.1109/FREQ.2000.887325 ↗
11. 10.1063/1.213038610.1063/1.2130386 ↗
12. 10.1016/j.snb.2013.10.07610.1016/j.snb.2013.10.076 ↗
13. 10.1038/354056a010.1038/354056a0 ↗
14. Surface modifications for the effective dispersion of carbon nanotubes in solvents and polymers10.1016/j.carbon.2011.08.011 ↗
15. 10.1166/nnl.2011.112310.1166/nnl.2011.1123 ↗
16. 10.1016/S0008-6223(97)00144-910.1016/S0008-6223(97)00144-9 ↗
17. 10.1021/acs.langmuir.6b0364010.1021/acs.langmuir.6b03640 ↗
18. 10.1016/j.snb.2011.12.03710.1016/j.snb.2011.12.037 ↗
19. 10.1073/pnas.090584410610.1073/pnas.0905844106 ↗
20. 10.1063/1.369193610.1063/1.3691936 ↗
21. 10.1063/1.488031610.1063/1.4880316 ↗
22. 10.1016/j.snb.2015.07.02410.1016/j.snb.2015.07.024 ↗
23. 10.1016/j.snb.2012.12.03310.1016/j.snb.2012.12.033 ↗
24. 10.1016/S0032-3861(98)00557-610.1016/S0032-3861(98)00557-6 ↗
25. 10.1021/ac951203m10.1021/ac951203m ↗
26. 10.1016/j.snb.2016.01.01510.1016/j.snb.2016.01.015 ↗
27. 10.1109/IWASI.2007.442004510.1109/IWASI.2007.4420045 ↗
28. Ultrafast response humidity sensor using supramolecular nanofibre and its application in monitoring breath humidity and flow10.1038/srep04103 ↗
29. Impedance scanning QCM studies of aniline electropolymerization in aqueous phosphoric acid solutions to determine the most effective acid concentration
30. ballantine · Acoustic Wave Sensors Theory Design and Physico-Chemical Applications · 1997 · 73
31. 10.1063/1.346080510.1063/1.3460805 ↗
32. 10.1016/j.snb.2003.12.00210.1016/j.snb.2003.12.002 ↗
33. 10.1186/s11671-015-0882-710.1186/s11671-015-0882-7 ↗
34. 10.1016/j.msea.2015.02.05710.1016/j.msea.2015.02.057 ↗
35. 10.1016/j.carbon.2008.10.04110.1016/j.carbon.2008.10.041 ↗