A miniaturized helical antenna is presented in this work. The antenna is flexible, it is 6100 μm long and it has a diameter of 352 μm. This antenna has such a small cross-section, that permits to be implanted in the human body with fine syringes and minimally invasive surgeries. The antenna can be used to receive power and/or send information in medical devices. The antenna is made of biocompatible materials: polytetrafluoroethylene (PFTE) and copper. The fundamental parameters of the antenna have been simulated and experimentally measured in animal human-like tissues, showing good agreement. The resonant frequency of the antenna is 4.7 GHz, with a reflection coefficient of -25.1 dB, and a gain of -4.7 dBi. As expected, the resonant frequency decreases inside biological tissues comparing to the free-space open-air measurement. Reducing the resonant frequency is an advantage because power signals can penetrate deeper into body tissues.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wireless Body Area Networks · Wireless Power Transfer Systems · Energy Harvesting in Wireless Networks

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Signal Theory and Communications Department, Mechanical Engineering Area, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain

Signal Theory and Communications Department, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain

References (29)

Show source-provided references
1. 10.1109/TBCAS.2016.251554110.1109/TBCAS.2016.2515541 ↗
2. lannoye · La Pollution e?lectromagne?tique Et La Sante? Vers Une Mai?Trise Des Risques · 1994
3. Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz)10.1097/HP.0000000000001210 ↗
4. IEEE Standard for Safety Levels with Respect to Human Exposure to Electric Magnetic and Electromagnetic Fields 0 Hz to 300 GHz · 2019
5. 10.1109/TBME.2006.87779810.1109/TBME.2006.877798 ↗
6. 10.3390/s2109320110.3390/s21093201 ↗
7. 10.1038/am.2015.5310.1038/am.2015.53 ↗
8. 10.1109/TAP.2014.236407410.1109/TAP.2014.2364074 ↗
9. 10.1109/ACCESS.2019.290230810.1109/ACCESS.2019.2902308 ↗
10. 10.1109/TAP.2011.216143610.1109/TAP.2011.2161436 ↗
11. Compilation of the dielectric properties of body tissues at RF and microwave frequencies
12. 10.1109/TBME.2011.218205010.1109/TBME.2011.2182050 ↗
13. 10.1109/TMECH.2022.321523310.1109/TMECH.2022.3215233 ↗
14. 10.1109/TBME.2017.266861210.1109/TBME.2017.2668612 ↗
15. 10.1115/1.405449510.1115/1.4054495 ↗
16. NTP 234 Exposición a Radiofrecuencias y Microondas (I) Evaluación · 1989
17. 10.1109/TBME.2011.211265910.1109/TBME.2011.2112659 ↗
18. 10.6028/jres.064D.00310.6028/jres.064D.003 ↗
19. 10.1063/1.171503810.1063/1.1715038 ↗
20. 10.3390/signals102001210.3390/signals1020012 ↗
21. 10.1109/CCE.2008.457899010.1109/CCE.2008.4578990 ↗
22. 10.1109/TIE.2018.283537810.1109/TIE.2018.2835378 ↗
23. 10.1109/TBME.2020.303398610.1109/TBME.2020.3033986 ↗
24. 10.1109/TNANO.2006.87743010.1109/TNANO.2006.877430 ↗
25. 10.1109/TBME.2019.293722410.1109/TBME.2019.2937224 ↗
26. 10.1109/TNANO.2014.229939910.1109/TNANO.2014.2299399 ↗
27. 10.1109/TNANO.2012.219075210.1109/TNANO.2012.2190752 ↗
28. Ansys HFSS | 3D high frequency simulation software
29. 10.1109/TNANO.2011.217747410.1109/TNANO.2011.2177474 ↗