The Fabrication and Sensing Characteristics of Arrayed Flexible IGZO/Al Urea Biosensor Modified by Graphene Oxide
Source abstract
Abstract
The urease membrane was immobilized on the surface of indium gallium zinc oxide (IGZO) based on polyethylene terephthalate substrate, which was used to develop an arrayed flexible urea biosensor in this study. In order to improve the properties of arrayed flexible IGZO/Al urea biosensor, graphene oxide (GO) was employed to modify the properties of arrayed flexible IGZO urea biosensor. Compared with the average sensitivity of 1.53 mV/(mg/dl) and linearity of 0.931 for arrayed flexible IGZO/Al urea biosensor, the average sensitivity and linearity of arrayed flexible IGZO urea biosensor modified by GO achieved 3.06 mV/(mg/dl) and 0.970, respectively. As the result, 5 mM pH 7.0 PBS buffer solution was the optimal measurement environment for Urease/IGZO/GO/Al urea biosensor, and which the average sensitivity was 3.65 [mV/(mg/dl)]. Anti-interference testing showed the arrayed flexible IGZO/Al urea biosensor modified by GO was not easily interfered from the other materials.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. 10.1016/j.bios.2013.08.04310.1016/j.bios.2013.08.043 ↗
2. 10.1016/j.bios.2015.07.00210.1016/j.bios.2015.07.002 ↗
3. 10.1109/JSEN.2017.265449210.1109/JSEN.2017.2654492 ↗
4. Study of disposable urea sensor and the pre-amplifier
5. 10.1016/j.snb.2015.08.10610.1016/j.snb.2015.08.106 ↗
6. 10.1016/j.snb.2015.06.13710.1016/j.snb.2015.06.137 ↗
7. 10.1109/JSEN.2013.228045510.1109/JSEN.2013.2280455 ↗
8. Optical biosensor for urea with improved response time, biosens and bioelectron
9. Portable urea biosensor based on the extended base bipolar junction transistor
10. 10.1109/JSEN.2005.85788110.1109/JSEN.2005.857881 ↗
11. 10.1109/JSEN.2011.215978610.1109/JSEN.2011.2159786 ↗
12. 10.1109/JSEN.2013.225049710.1109/JSEN.2013.2250497 ↗
13. 10.1109/JSEN.2015.250698610.1109/JSEN.2015.2506986 ↗
14. 10.1109/JSEN.2015.243928810.1109/JSEN.2015.2439288 ↗
15. 10.1016/S1872-2075(08)60031-X10.1016/S1872-2075(08)60031-X ↗
16. 10.1016/j.bios.2013.10.04310.1016/j.bios.2013.10.043 ↗
17. 0
18. Fabrication of arrayed flexible screen-printed biosensor based on different and microfluidic
19. 10.1016/j.bios.2012.05.03310.1016/j.bios.2012.05.033 ↗
20. 10.1016/S0925-4005(97)00194-910.1016/S0925-4005(97)00194-9 ↗
21. 10.1016/j.msec.2011.06.00310.1016/j.msec.2011.06.003 ↗
22. 10.1016/j.talanta.2012.08.01610.1016/j.talanta.2012.08.016 ↗
23. 10.1109/TRANSDUCERS.2015.718119710.1109/TRANSDUCERS.2015.7181197 ↗
24. Research of stability and interference with the potentiometric flexible arrayed glucose sensor based on microfluidic framework10.1109/TSM.2014.2359031 ↗