Tensile-Force-Resilient Biomedical Front-End Circuits Employing Auto-Calibrated Omni-Directional Thin-Film Transistors
Source abstract
Abstract
Flexible electronics based on thin film transistors (TFTs) are expected to deliver important benefits in the mobile healthcare field. Nevertheless, the mechanical strain caused by the respiration or movement of organisms seriously affects the characteristics of the TFTs, and thus deteriorates the performance of TFT-based circuits and systems. Taking indium-gallium-zinc-oxide (IGZO) TFT as an example, this paper proposes a tensile-force-resilient biomedical front-end system based on omni-directional thin film transistors (OD TFTs). The proposed OD TFT is a combination of dual gate TFTs with optimized layout, whose force-insensitive axis can be adjusted by the biasing of top gate. Based on this, an auto calibration technique in front-end system is introduced, which can automatically adjust the top gate biasing of OD TFTs according to the Poisson's ratio of substrate and the direction of external force, so as to align the force-insensitive axis along the direction of external force. Employing the OD TFTs in circuits and the auto calibration technique, the force resilience of the flexible electronic system is significantly improved in practical applications. The simulations of front-end system on acquiring electrocardiogram (ECG) and electromyogram (EMG) signals are performed. The results show that the proposed front-end system with auto calibration provides an increase of SNR from initial -19.91 dB and -25.89 dB without calibration to 17.53 dB and 1.32 dB in two cases, respectively.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Thin-Film Transistor Technologies · Advanced Sensor and Energy Harvesting Materials · Nanowire Synthesis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Micro/Nano Electronics & Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai, China
Beijing Institute of Mechanical Equipment, Beijing, China
School of Aerospace Engineering, Tsinghua University, Beijing, China
Funding
National Key Research and Development Program of China
References (50)
Show source-provided references
1. 10.1109/VLSI-DAT.2019.874203210.1109/VLSI-DAT.2019.8742032 ↗
2. 10.1109/TNANO.2018.284163910.1109/TNANO.2018.2841639 ↗
3. 10.1109/ISSCC.2016.741802310.1109/ISSCC.2016.7418023 ↗
4. 10.1109/JSSC.2016.259829510.1109/JSSC.2016.2598295 ↗
5. 10.1109/EMBC.2017.803720610.1109/EMBC.2017.8037206 ↗
6. 10.1109/JETCAS.2016.261672310.1109/JETCAS.2016.2616723 ↗
7. 10.1109/IWASI.2019.879132110.1109/IWASI.2019.8791321 ↗
8. 10.1109/TNANO.2018.280264910.1109/TNANO.2018.2802649 ↗
9. 10.1109/LED.2018.282545410.1109/LED.2018.2825454 ↗
10. 10.1109/JEDS.2017.275165110.1109/JEDS.2017.2751651 ↗
11. 10.1109/LED.2015.244227110.1109/LED.2015.2442271 ↗
12. 10.1109/EMBC.2015.732025210.1109/EMBC.2015.7320252 ↗
13. 10.1109/IFETC.2018.858394910.1109/IFETC.2018.8583949 ↗
14. 10.1002/sdtp.1232210.1002/sdtp.12322 ↗
15. 10.1002/aelm.20200067410.1002/aelm.202000674 ↗
16. 10.1039/d2mh00470d10.1039/d2mh00470d ↗
17. 10.1038/nature2549410.1038/nature25494 ↗
18. 10.1126/science.abh355110.1126/science.abh3551 ↗
19. 10.1109/LED.2020.298012310.1109/LED.2020.2980123 ↗
20. 10.1109/TNANO.2016.257343810.1109/TNANO.2016.2573438 ↗
21. 10.1109/ISCAS51556.2021.940172710.1109/ISCAS51556.2021.9401727 ↗
22. 10.1109/OJCAS.2021.312339610.1109/OJCAS.2021.3123396 ↗
23. 10.1109/TNANO.2006.88852710.1109/TNANO.2006.888527 ↗
24. 10.1109/LED.2018.285454110.1109/LED.2018.2854541 ↗
25. 10.1109/TED.2017.265511010.1109/TED.2017.2655110 ↗
26. 10.1109/JEDS.2019.292101810.1109/JEDS.2019.2921018 ↗
27. 10.1016/j.polymertesting.2018.05.04410.1016/j.polymertesting.2018.05.044 ↗
28. 10.1002/sdtp.1314510.1002/sdtp.13145 ↗
29. 10.1109/IFETC.2018.858391510.1109/IFETC.2018.8583915 ↗
30. 10.1109/ICEPT.2018.848068410.1109/ICEPT.2018.8480684 ↗
31. 10.1016/j.mssp.2020.10541710.1016/j.mssp.2020.105417 ↗
32. 10.1109/ISSCC.2017.787036010.1109/ISSCC.2017.7870360 ↗
33. 10.1109/ISCAS51556.2021.940170410.1109/ISCAS51556.2021.9401704 ↗
34. 10.1109/TNANO.2016.254285110.1109/TNANO.2016.2542851 ↗
35. 10.1109/ASSCC.2014.700892310.1109/ASSCC.2014.7008923 ↗
36. 10.1109/MWSCAS.2015.728205110.1109/MWSCAS.2015.7282051 ↗
37. 10.1109/JEDS.2019.292320810.1109/JEDS.2019.2923208 ↗
38. 10.1109/JSSC.2018.283121110.1109/JSSC.2018.2831211 ↗
39. 10.1109/ISCAS.2017.805068210.1109/ISCAS.2017.8050682 ↗
40. 10.1109/OJCAS.2021.312320610.1109/OJCAS.2021.3123206 ↗
41. 10.1109/51.93272410.1109/51.932724 ↗
42. 10.1161/01.CIR.101.23.e21510.1161/01.CIR.101.23.e215 ↗
43. 10.3389/fphys.2018.0056610.3389/fphys.2018.00566 ↗
44. 10.1021/acsami.7b1450110.1021/acsami.7b14501 ↗
45. Flexible bluetooth antennas integrated with electrodes for wearable ECG sensors
46. 10.1002/advs.20190093910.1002/advs.201900939 ↗
47. 10.1002/aelm.20200086510.1002/aelm.202000865 ↗
48. Mechanical properties of skin
49. 10.1016/j.sna.2015.04.01110.1016/j.sna.2015.04.011 ↗
50. 10.1007/s10544-019-0379-810.1007/s10544-019-0379-8 ↗