Abstract

The design and fabrication of an active multiaxis probing system for high-speed atomic force microscopy is presented. The probing system employs a multiaxis compliant manipulator that is actuated by two magnetic actuators to control the tip position simultaneously along the vertical and the lateral directions. The manipulator is optimally designed to achieve high bandwidth actuation and large scanning range. A novel process to fabricate multiaxis compliant manipulators reliably by using focused ion beam milling is proposed. The fabricated active multiaxis probing system is demonstrated to have high bandwidth of actuation with the lateral and vertical resonance frequencies at 46.4 and 101.5 kHz, respectively. The lateral scanning range is estimated to be ~350 nm at a magnetic field of 20 × 10-4 T. It enables imaging rate of 10 frame/s with pixel resolution of 100 × 100 pixels.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Force Microscopy Techniques and Applications · Integrated Circuits and Semiconductor Failure Analysis · Near-Field Optical Microscopy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. 10.1002/cphc.20030079510.1002/cphc.200300795 ↗
2. 10.1016/j.ultramic.2006.01.01510.1016/j.ultramic.2006.01.015 ↗
3. 10.1088/0957-4484/19/38/38401810.1088/0957-4484/19/38/384018 ↗
4. 10.1063/1.185540710.1063/1.1855407 ↗
5. 10.1063/1.284180510.1063/1.2841805 ↗
6. 10.1063/1.243482510.1063/1.2434825 ↗
7. 10.1063/1.12106410.1063/1.121064 ↗
8. a magnetically driven oscillating probe microscope for operation in liquid10.1063/1.117835 ↗
9. Method and apparatus for magnetic force control of a scanning probe · 1999
10. 10.1063/1.218886710.1063/1.2188867 ↗
11. 10.1016/j.jsb.2007.07.00910.1016/j.jsb.2007.07.009 ↗
12. conformational change of the hexagonally packed intermediate layer of deinococcus radiodurans monitored by atomic force microscopy10.1128/jb.178.11.3025-3030.1996 ↗
13. 10.1016/j.jmb.2007.09.02210.1016/j.jmb.2007.09.022 ↗
14. 10.1016/S0006-3495(99)77275-910.1016/S0006-3495(99)77275-9 ↗
15. 10.1063/1.278515810.1063/1.2785158 ↗
16. 10.1063/1.220087410.1063/1.2200874 ↗
17. 10.1126/science.289.5478.42210.1126/science.289.5478.422 ↗
18. 10.1103/PhysRevLett.56.93010.1103/PhysRevLett.56.930 ↗
19. 10.1063/1.220395810.1063/1.2203958 ↗