The Back-End Calibration Circuit for Reducing Hysteresis and Drift Effects of the Potentiometric RuO2 Dopamine Biosensor
Source abstract
Abstract
Electrochemical biosensors often encounter inaccuracies and unreliability in measurements due to non-ideal effects such as drift and hysteresis. This study presents an innovative back-end calibration circuit specifically designed to mitigate hysteresis and drift effects in potentiometric ruthenium dioxide (RuO2) dopamine biosensors. The proposed calibration circuit combines analog circuitry with a microcontroller, employing gain-configured inverting amplifiers to individually correct hysteresis effects induced by both low and high dopamine concentrations. Furthermore, an inverse drift signal is applied to counteract overall drift effects, significantly improving the precision of dopamine measurements. The biosensor utilizes a radiofrequency sputtering system to deposit RuO2 as a sensing membrane. A sequential drop-casting process is employed to add functional layers. Atomic force microscopy is utilized to characterize the surface morphology of the RuO2 sensing membrane, confirming its uniform pattern and exceptional flatness. Reproducibility and repeatability experiments validate the stability and consistency of the fabricated RuO2 dopamine biosensor, underscoring its potential for practical applications in the diagnosis of neurological disorders.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Electrochemical sensors and biosensors · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliou, Taiwan
Graduate School of Chemical and Materials Engineering, National Yunlin University of Science and Technology, Douliou, Taiwan
Funding
National Science and Technology Council · Technical Support from the Taiwan Semiconductor Research Institute
References (28)
Show source-provided references
1. 10.1002/smll.20140326310.1002/smll.201403263 ↗
2. 10.3390/s1909203710.3390/s19092037 ↗
3. 10.1007/s10571-018-0632-310.1007/s10571-018-0632-3 ↗
4. 10.4172/2471-271X.100012010.4172/2471-271X.1000120 ↗
5. 10.1038/nrn98310.1038/nrn983 ↗
6. 10.1016/j.neubiorev.2003.08.00610.1016/j.neubiorev.2003.08.006 ↗
7. 10.1016/j.microc.2018.10.00410.1016/j.microc.2018.10.004 ↗
8. 10.1016/j.aca.2010.11.01010.1016/j.aca.2010.11.010 ↗
9. 10.1016/0014-2999(75)90105-310.1016/0014-2999(75)90105-3 ↗
10. 10.3390/bios1106017910.3390/bios11060179 ↗
11. 10.1080/10408347.2019.166428110.1080/10408347.2019.1664281 ↗
12. 10.1186/s40824-019-0181-y10.1186/s40824-019-0181-y ↗
13. 10.1109/TED.2023.333071010.1109/TED.2023.3330710 ↗
14. 10.1149/2.0021505jes10.1149/2.0021505jes ↗
15. 10.1016/S0925-4005(02)00147-810.1016/S0925-4005(02)00147-8 ↗
16. 10.1016/j.snb.2003.09.01510.1016/j.snb.2003.09.015 ↗
17. 10.1109/JSEN.2010.208774510.1109/JSEN.2010.2087745 ↗
18. 10.1149/1945-7111/ab8ce610.1149/1945-7111/ab8ce6 ↗
19. 10.1016/j.trac.2023.11750910.1016/j.trac.2023.117509 ↗
20. 10.1016/0925-4005(94)87044-610.1016/0925-4005(94)87044-6 ↗
21. 10.1016/S0925-4005(97)00166-410.1016/S0925-4005(97)00166-4 ↗
22. 10.1016/j.aeue.2020.15312010.1016/j.aeue.2020.153120 ↗
23. 10.1016/0925-4005(93)85131-S10.1016/0925-4005(93)85131-S ↗
24. 10.1016/S0925-4005(98)00040-910.1016/S0925-4005(98)00040-9 ↗
25. 10.1016/0925-4005(90)80018-U10.1016/0925-4005(90)80018-U ↗
26. 10.1016/0925-4005(91)80018-F10.1016/0925-4005(91)80018-F ↗
27. 10.1016/0250-6874(83)85032-X10.1016/0250-6874(83)85032-X ↗
28. 10.1016/j.watres.2021.11716410.1016/j.watres.2021.117164 ↗