article·2002-08-01Open access

On improving the spectral purity of the regenerated clock signal in a data clock recovery circuit

Madhusudan Ghosh, Archita Hati, B. C. Sarkar

Open full text

Abstract

For the recovery of the information embedded in the received data stream at the destination point of a digital communication system, the knowledge about the transmitter clock timings is very importantt.2. Since a separate transmission of the clock timing in­ formation is a misuse of the transmitter power and channel bandwidth, it is always desirable to recon­ struct the clock signal from the received data stream. When the received data stream contains an energy component at the clock signal frequency, it becomes easy to recover the clock signal from the received data stream. However in the case of commonly used non­ return to zero (NRZ) type data stream, the clock sig­ nal component is absent and some non-linear proc­ essing is needed to regenerate the clock signal. In synchronous techniques of clock recovery, either the data stream is first passed through a non-linear circuit and then a phase locked loop (PLL) is used to recon­ struct the clock signal, or a non-linear phase locked loop is employed to reconstruct the clock signal. The latter type uses a specially designed phase detector (PD) capable of producing synchronising signal for the loop voltage controlled oscillator (YCO) and comparing the phase error between the data signal and the YCO signal at the transition instants of data sig­ nal l ,3. Among different types of PDs used for this purpose, one proposed by Hogge 4 has been studied elaborately in the literature and a few modifications of the basic structure have been suggested in order to remove some of its inherent defects (described in de­ tails in the following paragraph)5. The present paper reports a simple modification of the conventional structure of the Hogge phase detector (HPD). It uses a charge pump circuit to convert the digital error signal into an analog signal and then makes use of a sample and hold circuit to produce discrete natured synchro­ nising signal for the loop YCO. It has been estab­ lished both qualitatively and experimentally that the modified structure improves the performance of the clock recovery circuit (CRC) in respect of phase noise of the recovered clock signal. The paper is organised in the following way: The principle of operation of the conventional HPD (CHPD) in order to throw light on the inherent problems of this circuit. Then it sug­ gests a modification of the system structure which can improve the system response. The reasons of per­ formance improvement of the system due to the sug­ gested modifications have been attempted. The details of experimental set-up along with the results obtained to support the predicted performance improvement are given.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advancements in PLL and VCO Technologies · Advanced Electrical Measurement Techniques · Blind Source Separation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.