Dynamic behaviour of indirect coupled heat exchanger systems
Source abstract
Abstract
In thi s paper, t. e dynamic behaviour of the indirect coupled heat exchanger system has been reported. Three parti al differential equations of energy balance for three fluid s have been derived and solved simultaneously by adopting th e finit e element method. The responses of couplin g fluid temperatures, hot and cold fluid temperatures have been studi ed for th e step and sinu soidal changes in hot fluid inlet temperature. The maximum over-all effectiveness of the system has occurred at a unique value of th e non-dimensional coupling fluid heat capacity rate. This unique value is ide ntical to th e value, which could be obtained flOm an analytically derived equation by the previous investi gato r. However, as expected, th e situa ti on changes when th ere is sinusoidal change in hot fluid inlet temperature. Sometimes, due to th e restriction in the plant design or else to avoid contamination of th e cold fluid from the hot fluid as well as in the waste heat recovery systems, the hot and cold fluids cannot be brought to their closed proximity to exchange thermal energy. In these typical situation s, the transfer of thermal energy is still possible throu gh an intermediate fluid called 'coupling fluid' . Thus , the indirect coupled heat exchanger system cc nsists of two heat exchanger units called 'hot end' and 'cold end' heat exchangers, together with a circull tion system for circulating the coupling fluid at deslred mass flow rate. With thi s arrangement the circulating fluid (coupling fluid) transfers the thermal energy from the hot fluid to the cold fluid . In such a system the inlet condition of hot fluid at th e entry of hot end heat exchanger may not remain constant and may vary with time. Consequently, the temperatures of coupli ng fluid at the inl et and exit of the two end heat exchangers would not remain constant and will also vary with time. This result into variation of amount of thermal energy transferred from hot fluid to cold fluid which may in tum show it s effect on the perfolrmance as well as the optimum mass flow rate of cou.pling fluid for maximizing the system overall-effectiveness, as derived by Holmberg'. Kays and London 2 derived in connection with heat recovery in gas-turbine plants the optimum coupling fluid rate for the special case of equal hot fluid and cold fluid capacity rates for counter flow
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Heat Transfer and Optimization · Greenhouse Technology and Climate Control · Adsorption and Cooling Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.