Quantitative measurement of pigment diffusion by automatic image profile scan technique
Source abstract
Abstract
A technique combining light transmission microscopy with computer analysis of an image profile has been developed for the quantitative measurement of the migration behaviour of pigment molecules dispersed in plasticised poly(vinyl chloride). The technique is based on the interactive hard- and soft-ware programs which generated an analogue to digital conversion of a photometer response to a gamma corrected luminance signal output of the li ght intensity with decreasing pigment concentration in the direction of the diffusion . This technique provides a precise and quantitative assessment of the suitability of pigments as additives in polymeric systems. The migration behaviour of pigment additives in polymeric systems in relation to the phenomeno logical problem of bleeding has generated a lot of research interests over the years. In thi s regards , techniques designed to measure the migration behaviour of additives in polymerics have been reported J - 5 . Worthy of mention are microspectro metric. m icrodeositometric and the tracer diffusion methods. The limitations in these techniques ran ge from distorted sections and poor photometric response to destructive oxidation products of the additives by sci ntillations 6 . The poor results obtained with automatic quantiment and semi-automatic scintillation co unter ari se from surface activity of diffusing molecules. In particular, personal errors in the operation of the equipment undefined boundary con di ti ons and poor interpretation of res ults may render th e results unre liable and the exercise futile . The work reported here is a high accuracy tech nique , equipped with data generation sys tem and capab le of measurin g quantitatively the diffusion coeffici ent of pigments in plastics of th ickne ss and pigment concentrations of pract ical significa nce . The mai n feature of the technique is the measurement of tran smitted li gh t int ensity out-put signa s th rou gh an image pro file along the diffusion gradient. Al though the bas ic principle involved is optical section ing, there is no physi cal movement of the sample or the microscope sta&e rathe r the magnified image of the ' Fo r all correspon dence sa mple is viewed by means of a television camera of wavelength range 400-750 nm which enabled an hori zontal resolution of 625 lines on the sample image to be achieved . It is this line resolution that perform s the optical sectioning. In addition, all the information required to test the validity of the technique is ge nerated in a single scan .
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Spectroscopy and Chemometric Analyses · Color Science and Applications · Cultural Heritage Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.