article·1994-12-01Open access

Freezing points of high purity lead as precision temperature standards

R. S. Georgiuss

Open full text

Abstract

An investigation of freezing and melting temperature of two samples of lead (purity > 99.99%) has been made. Using the induced freezing technique, plateaus of essentially constant (± 0.0002°C) temperature with duration of 3 h are obtained on the cooling curves of these samples. Alloy melting ranges have been measured following different types of freezing with overnight anneals near the solidus temperature. These parameters are found to be useful in the selection of the samples of the highest purity and at the same time showed that an uncertainty of 0.004°C above the value of the liquidus point may exist
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: thermodynamics and calorimetric analyses · Scientific Measurement and Uncertainty Evaluation · Calibration and Measurement Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.