article·1999-02-01Open access

Analysis of linear SISO (single input single output) control systems with sample and- hold using block pulse function (BPF) operational technique

Anish Deb, Gautam Sarkar, Manabrata Bhattacharjee, Sunit Kumar Sen

Open full text

Abstract

An operational technique using block pulse functions (BPF) for the analysis of control systems with sample-and-hold (S/H) is proposed. Using this technique, the output in the BPF domain is obtained by means of simple matrix multiplication . Thus, laborious algebraic manipulations associated with the z-transform technique are avoided. Also, the method needs no inverse transformation , generally associated with Laplace or z-transformation . The BPF operational matrix for differentiation D is utilised to replace the Laplace operator s in the conventional transfer function G (s). The resulting operational transfer function is termed block pulse operational transfer function (BPOTF). This BPOTF is used in conjunction with a sample-and-hold matrix S to analyse a feedback control system with sample-and-hold. Since the BPOTF is always a triangular matrix, any computation involving BPOTF, e.g., matrix inversion or multiplication, is rather simple as far as computational burden is concerned. The results thus obtained are compared with the exact solution. The present operational method is simple and the accuracy of the results are acceptable. Piecewise constant basis functions (PCBFs) have been around in the literature for about eight decades). Of all PCBFs, the block pulse function (BPF) turned out to be the most fundamental and its qualitative as well as quantitative appraisal were presented by Deb et af.2 in a recent publication. The set of BPFs has been used successfully by many researchers for the analysis, synthesis and design of control systems. The block pulse function resembles the output of a sample-and-hold (S/H) device and hence, it seems pertinent that the usefulness of the BPF set may be explored for the analysis of sampled data control systems. The only effort in this direction seems to be by Chen and Wu 3 The present paper proposes an alternative simple operational method for the analysis of sampled-data systems using block pulse functions . In this method, the output in the BPF domain is obtained by means of simple matrix multiplication . Thus, laborious algebraic manipUlations associated with the z­ transform technique are avoided. Also, the method needs no inverse transformation, generally associated with Laplace or z-transformation. The operational matrix for differentiation D in the BPF domain is utilised to replace the Laplace operator s in the conventional transfer function G (s). The resulting operational transfer function is termed block pulse operational transfer function (BPOTF). This BPOTF is used in conjunction with a sample-and­ hold matrix S proposed by Chen and Wu 3 to analyse a feedback control system with sample-and-hold. The results obtained are compared with the exact solution (Fig. I). The present operational method is an easier alternative to the BPF technique proposed earlier 3 , with the same degree of accuracy. An example is treated as an illustration to justify the validity of the proposal.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Control Systems and Identification · Sensor Technology and Measurement Systems · Advanced Control Systems Design

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.