journal article·2022-01Open access

Improved localization precision via restricting confined biomolecule stochastic motion in single‐molecule localization microscopy

Jielei Ni, Bo Cao, Gang Niu, Danni Chen, Guotao Liang, Tingying Xia, Heng Li, Chen Xu, Jingyu Wang, Wanlong Zhang, Yilin Zhang, Xiaocong Yuan, Yanxiang Ni

Nanophotonics· Volume 11· Issue 1

Abstract

Abstract Single‐molecule localization microscopy (SMLM) plays an irreplaceable role in biological studies, in which nanometer‐sized biomolecules are hardly to be resolved due to diffraction limit unless being stochastically activated and accurately located by SMLM. For biological samples preimmobilized for SMLM, most biomolecules are cross‐linked and constrained at their immobilizing sites but still expected to undergo confined stochastic motion in regard to their nanometer sizes. However, few lines of direct evidence have been reported about the detectability and influence of confined biomolecule stochastic motion on localization precision in SMLM. Here, we access the potential stochastic motion for each immobilized single biomolecule by calculating the displacements between any two of its localizations at different frames during sequential imaging of Alexa Fluor‐647‐conjugated oligonucleotides. For most molecules, localization displacements are remarkably larger at random frame intervals than at shortest intervals even after sample drift correction, increase with interval times and then saturate, showing that biomolecule stochastic motion is detected and confined around the immobilizing sizes in SMLM. Moreover, localization precision is inversely proportional to confined biomolecule stochastic motion, whereas it can be deteriorated or improved by enlarging the biomolecules or adding a post‐crosslinking step, respectively. Consistently, post‐crosslinking of cell samples sparsely stained for tubulin proteins results in a better localization precision. Overall, this study reveals that confined stochastic motion of immobilized biomolecules worsens localization precision in SMLM, and improved localization precision can be achieved via restricting such a motion.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Fluorescence Microscopy Techniques · Advanced Electron Microscopy Techniques and Applications · Force Microscopy Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Nanophotonics Research Center Shenzhen Key Laboratory of Micro‐Scale Optical Information Technology and Institute of Microscale Optoelectronics College of Physics and Optoelectronic Engineering College of Electronics and Information Engineering Shenzhen University Shenzhen 518060 China

Dr. Neon Technology Ltd Shenzhen 518060 China

Phil Rivers Technology Beijing 100871 China

Joint Turing‐Darwin Laboratory of Phil Rivers Technology Ltd. and Institute of Computing Technology, Chinese Academy of Sciences Beijing 100190 China

Western Institute of Computing Technology, Chinese Academy of Science Chongqing 400000 China

Hefei National Laboratory for Physical Sciences at Microscale School of Basic Medical Sciences Division of Life Sciences and Medicine University of Science and Technology of China Hefei 231299 China

Tsinghua‐Berkeley Shenzhen Institute (TBSI) Tsinghua University Shenzhen 518055 China

Funding

National Natural Science Foundation of China · Shenzhen Peacock Plan · Natural Science Foundation of Guangdong Province

References (40)

Show source-provided references
1. 10.1038/nmeth92910.1038/nmeth929 ↗
2. 10.1002/anie.20080237610.1002/anie.200802376 ↗
3. 10.1038/nprot.2011.33610.1038/nprot.2011.336 ↗
4. 10.1126/science.112734410.1126/science.1127344 ↗
5. 10.1529/biophysj.106.09111610.1529/biophysj.106.091116 ↗
6. 10.1126/science.115352910.1126/science.1153529 ↗
7. 10.1016/j.cell.2010.12.00210.1016/j.cell.2010.12.002 ↗
8. 10.1038/s43586‐021‐00038‐x10.1038/s43586‐021‐00038‐x ↗
9. 10.1126/science.114659810.1126/science.1146598 ↗
10. 10.1038/nprot.2008.24610.1038/nprot.2008.246 ↗
11. 10.1038/nmeth.125810.1038/nmeth.1258 ↗
12. 10.1039/c3cp53719f10.1039/c3cp53719f ↗
13. 10.1038/nmeth.f.31410.1038/nmeth.f.314 ↗
14. 10.1039/c3cp44693j10.1039/c3cp44693j ↗
15. 10.1016/s0006‐3495(02)75618‐x10.1016/s0006‐3495(02)75618‐x ↗
16. 10.1038/nmeth.284310.1038/nmeth.2843 ↗
17. 10.1364/oe.20.01217710.1364/oe.20.012177 ↗
18. 10.1038/ncomms876410.1038/ncomms8764 ↗
19. 10.1364/ol.39.00568510.1364/ol.39.005685 ↗
20. 10.1016/s0006‐3495(00)76712‐910.1016/s0006‐3495(00)76712‐9 ↗
21. 10.1038/nmeth.144710.1038/nmeth.1447 ↗
22. 10.1038/s41377‐018‐0031‐z10.1038/s41377‐018‐0031‐z ↗
23. 10.1364/optica.2.00098510.1364/optica.2.000985 ↗
24. C. R.Copeland R. G.Dixson A. L.Pintar R. B.Llic andS. M.Stavis.“Subnanometer traceability of localization microscopy ”arXiv preprint arXiv:2106.10221 2021.
25. 10.1038/s41587‐020‐00753‐y10.1038/s41587‐020‐00753‐y ↗
26. 10.1038/ncomms814710.1038/ncomms8147 ↗
27. 10.1021/nl103427w10.1021/nl103427w ↗
28. 10.1038/nature0734110.1038/nature07341 ↗
29. 10.1074/mcp.m111.01405010.1074/mcp.m111.014050 ↗
30. 10.1117/1.ap.3.1.01400110.1117/1.ap.3.1.014001 ↗
31. 10.1016/j.cell.2013.09.04810.1016/j.cell.2013.09.048 ↗
32. 10.1021/nl304359p10.1021/nl304359p ↗
33. 10.1038/nmeth.199110.1038/nmeth.1991 ↗
34. 10.1038/s41592‐018‐0105‐010.1038/s41592‐018‐0105‐0 ↗
35. 10.7554/elife.2166010.7554/elife.21660 ↗
36. 10.1038/nmeth117110.1038/nmeth1171 ↗
37. 10.7498/aps.64.02870110.7498/aps.64.028701 ↗
38. 10.1038/nmeth.176810.1038/nmeth.1768 ↗
39. 10.1371/journal.pone.006900410.1371/journal.pone.0069004 ↗
40. 10.1039/c2cp43433d10.1039/c2cp43433d ↗