journal article·2024-04

Evaluation of the Use of Polyvinyl Alcohol in Preparation of Pressed Samples for X-ray Fluorescence Analysis

A. S. Segrenev, M. E. Prots

Inorganic Materials· Volume 60· Issue 4
Publisher page

Abstract

Abstract The reliability of results of X-ray fluorescence (XRF) analysis, a method widely used to determine the elemental composition of various materials, depends significantly on sample preparation quality. In preparing pressed pellets for XRF determination of trace elements, use is often made of a binder in powder form, which leads to considerable time expenditures for thorough homogenization. Here, we report our results on the use of a polyvinyl alcohol solution as a binder in the preparation of substrate-free pressed samples for XRF determination of trace elements. We present parameters that ensure preparation of a durable, homogeneous pellet that meets the condition of minimizing the effect on the intensity of analytical lines of the elements to be determined. The optimal sample weight in the proposed pressed pellet fabrication process is 7 g, polyvinyl alcohol is added in the ratio 7 : 1, and the optimal pellet drying time after pressing is 1 h. Calculated coefficients of variation of the analytical signal (<2%) suggest that the pellets we prepared are homogeneous. The maximum standard deviations for the ranges of elements chosen in the pressed pellets are far smaller than the acceptable standard deviations. This suggests that the proposed sample preparation procedure with the use of polyvinyl alcohol is appropriate. We demonstrate that, during prolonged storage and repeated measurements, pressed pellets prepared using a polyvinyl alcohol solution retain their initial structure, without changes in the intensity of the analytical lines of their constituent elements. Measurement accuracy in subsequent determination of rock-forming elements is consistent with their certified contents. The present results can be helpful for reducing the time needed for the preparation of a representative pressed sample in determination of elements without additional measures (coating films) and also in trace element and silicate analysis with the use of one sample.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical chemistry methods development · Analytical Chemistry and Chromatography · Adsorption, diffusion, and thermodynamic properties of materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Drozdov, A.A., Andreev, M.N., Ratnikov, D.S., and Bychkov, E.D., Determination of the composition of historical lead glass under museum storage conditions using a portable X-ray fluorescence analyzer, Zavod. Lab. Diagn. Mater., 2021, vol. 87, no. 6, pp. 14–19. https://doi.org/10.26896/1028-6861-2021-87-6-14-1910.26896/1028-6861-2021-87-6-14-19 ↗
2. Revenko, A.G. and Sharykina, D.S., Application of X-ray fluorescence analysis to study the chemical composition of tea and coffee, Anal. Control, 2019, vol. 23, no. 1, pp. 6–23. https://doi.org/10.15826/analitika.2019.23.1.01510.15826/analitika.2019.23.1.015 ↗
3. Talanova, V.N., Lependina, O.L., Kitaeva, D.Kh., and Buyanovskaya, A.G., Express method for X-ray fluorescence analysis of intercalation compounds for molybdenum content, Zavod. Lab. Diagn. Mater., 2020, vol. 86, no. 9, pp. 24–29. https://doi.org/10.26896/1028-6861-2020-86-9-24-2910.26896/1028-6861-2020-86-9-24-29 ↗
4. Drozdov, A.A., Andreev, M.N., Ratnikov, D.S., and Evdokimov, P.V., Determination of the composition of glasses produced at Lavinsky factories using X-ray fluorescence analysis and optical spectroscopy, J. Anal. Chem., 2021, vol. 76, no. 11, pp. 977–988. https://doi.org/10.31857/S004445022111005010.31857/S0044450221110050 ↗
5. Dudik, S.L., Kalinin, B.D., Rudnev, A.V., and Sergeev, Yu.I., Analysis of steels and alloys using X-ray spectrometers of the SPECTROSCAN MAX series, Zavod. Lab. Diagn. Mater., 2014, vol. 80, no. 1, pp. 19–26.
6. Chuparina, E.V. and Martynov, A.M., Application of non-destructive XRF to determine the elemental composition of medicinal plants, J. Anal. Chem., 2011, vol. 66, no. 4, pp. 399–405.10.1134/S106193481104006X ↗
7. Revenko, A.G., Application of X-ray fluorescence analysis in biology and medicine, Anal. Control, 2020, vol. 24, no. 4, pp. 236–276. https://doi.org/10.15826/analitika.2020.24.4.00510.15826/analitika.2020.24.4.005 ↗
8. Fiamegos, Y. and de la Calle Guntiñas, M.B., Validation strategy for an ED-XRF method to determine trace elements in a wide range of organic and inorganic matrices based on fulfilment of performance criteria, Spectrochim. Acta, Part B, 2018, vol. 150, pp. 59–66. https://doi.org/10.1016/j.sab.2018.10.00910.1016/j.sab.2018.10.009 ↗
9. Borkhodoev, V.Ya., Penevsky, S.D., and Sotskaya, O.T., Preparation of doped glass lithium-borate disks for X-ray fluorescence analysis of rocks on the VULCAN 4 melting plant, Analit. Kontrol’, 2013, vol. 17, no. 2, pp. 141–147.
10. Kuz’mina, T.G., Troneva, M.A., Kononkova, N.N., and Romashova, T.V., On the error of sample preparation when pressing emitters for X-ray fluorescence analysis, J. Anal. Chem., 2017, vol. 72, no. 3, pp. 272–278.10.1134/S1061934817030066 ↗
11. Rentgenofluorestsentnyi analiz. Primenenie v zavodskikh laboratoriyakh (X-ray Fluorescence Analysis. Application in Factory Laboratories), Moscow: Metallurgiya, 1985.
12. Kuzmina, T.G., Troneva, M.A., and Romashova, T.V., Role of petrogenic elements in the excitation of X-ray fluorescence of fluorine, J. Anal. Chem., 2020, vol. 75, no. 7, pp. 896–901. https://doi.org/10.1134/S106193482007013810.1134/S1061934820070138 ↗
13. Titarenko, A.V., Tsvetyansky, A.L., and Eritenko, A.N., Production of reference samples for X-ray fluorescence analysis, Analit. Kontrol’, 2008, vol. 12, nos. 1–2, pp. 42–45.
14. Zhdanov, P.A., Seregina, I.F., Bolshov, M.A., et al., Determination of the forms of occurrence of elements in samples of slag and sludge from vanadium production, Zavod. Lab. Diagn. Mater., 2015, vol. 81, no. 9, pp. 19–27.
15. Chuparina, E.V., Gunicheva, T.N., Belogolova, G.A., and Matyashenko, G.V., Application of X-ray fluorescence analysis to study the distribution of chemical elements in different parts of plants (using the example of Jerusalem artichoke), Analit. Kontrol’, 2005, vol. 9, no. 4, pp. 405–409.
16. Aisueva, T.S., Finkelshtein, A.L., Belozerova, O.Yu., and Skornikova, S.A., X-ray fluorescence determination of platinum, rhenium, palladium in catalysts based on aluminum oxide, Analit. Kontrol’, 2014, vol. 18, no. 4, pp. 411–417.
17. Orlić, J., Gržetić, I., and Ilijević, K., Effect of sample preparation procedure on standardless wavelength dispersive X-ray fluorescence analysis of plant samples, Spectrochim. Acta, Part B, 2021, vol. 184, p. 106258. https://doi.org/10.1016/j.sab.2021.10625810.1016/j.sab.2021.106258 ↗
18. Borkhodoev, V.Ya., Migration of sulfur in the X-ray fluorescence analysis of rocks, J. Anal. Chem., 2018, vol. 73, no. 7, pp. 627–630. https://doi.org/10.1134/S106193481805005210.1134/S1061934818050052 ↗
19. Gordienko, P.S., Yarusova, S.B., Sushkov, Yu.V., et al., Elemental, chemical and phase composition of a material based on calcium silicates obtained from technogenic waste, Persp. Mater., 2011, no. 11, pp. 144–149
20. Efremova, N.V., Soboleva, I.O., and Denisova, T.B., Selection of sample preparation method when developing a method for analyzing low-carbon ferrochrome using the X-ray fluorescence method at Mechel OJSC, Analit. Kontrol’, 2002, vol. 6, no. 4, pp. 445–448.