Analysis of high-purity materials by inductively coupled plasma mass spectrometry (Review)
Source abstract
Abstract
A review of the works dedicated to the application of the method of inductively coupled plasma mass spectrometry (ICP-MS) to the analysis of high-purity materials (semiconductors, metals, and their oxides) and published after 2004 is presented. The limitations of this method in the analysis of such objects are discussed. Advantages and disadvantages are demonstrated for three principal ways of the application of the ICP-MS method to the analysis of high-purity materials: direct analysis of a solid sample (laser ablation and injection of a sample in the form of a suspension); preliminary dissolution of an analyte sample; utilization of the approach separating analytes and matrix.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Analytical chemistry methods development · Laser-induced spectroscopy and plasma · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (72)
Show source-provided references
1. Charlton, B., Fisher, A.S., Goodall, P.S., Hinds, M.W., Lancaster, S., and Salisbury, M., Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials, J. Anal. At. Spectrom., 2007, vol. 22, no. 12, pp. 1517–1560.10.1039/b715992g ↗
2. Charlton, B., Fisher, A.S., Goodall, P.S., Hinds, M.W., Lancaster, S., and Shore, S., Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials, J. Anal. At. Spectrom., 2008, vol. 23, no. 12, pp. 1636–1692.10.1039/b817437g ↗
3. Carter, S., Fisher, A.S., Goodall, P.S., Hinds, M.W., Lancaster, S., and Shore, S., Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials, J. Anal. At. Spectrom., 2009, vol. 24, no. 12, pp. 1599–1656.10.1039/b920784h ↗
4. Carter, S., Fisher, A.S., Goodall, P.S., Hinds, M.W., Lancaster, S., and Shore, S., Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials, J. Anal. At. Spectrom., 2010, vol. 25, no. 12, pp. 1808–1858.10.1039/c005533f ↗
5. Becker, J.S. and Dietze H.-J., State-of-the-art in inorganic mass spectrometry for analysis of high-purity materials, Int. J. Mass Spectrom., 2003, vol. 228, nos. 2–3, pp. 127–150.10.1016/S1387-3806(03)00270-7 ↗
6. Shelpakova, I.R. and Saprykin A.I., Analysis of highpurity solids by atomic emission spectroscopy and mass spectrometry with atom excitation and ionisation in inductively coupled plasma, Russ. Chem. Rev., 2005, vol 74, no. 11, pp. 1015–1025.10.1070/RC2005v074n11ABEH000978 ↗
7. Inductively Coupled Plasma Mass Spectrometry, Montaser, A., Ed., New York: Wiley-VCH, 1998.
8. Taylor, H.E., Inductively Coupled Plasma-Mass Spectrometry. Practices and Techniques, San Diego: Academic, 2001.
9. De Laeter, J.R., Applications of Inorganic Mass Spectrometry, New York: Wiley, 2001.
10. ICP Mass Spectrometry Handbook, Nelms, S.M., Ed., Oxford: Blackwell, 2005.
11. Mora, J., Maestre, S., Hernandis, V., and Todolí J.L., Liquid-sample introduction in plasma spectrometry, Trends Anal. Chem., 2003, vol. 22, no. 3, pp. 123–132.10.1016/S0165-9936(03)00301-7 ↗
12. Surikov, V.T., Standard concentric pneumatic nebulizers for analytical spectrometry with inductively coupled plasma, Anal. Kontrol., 2007, vol. 11, no. 4, pp. 211–241.
13. Surikov, V.T., Cross-flow pneumatic nebulizers for spectrometry with inductively coupled plasma, Anal. Kontrol., 2010, vol. 14, no. 3, pp. 108–156.
14. Tanner, S.D., Baranov, V.I., and Bandura, D.R., Reaction cells and collision cells for ICP-MS: a tutorial review, Spectrochim. Acta, Part B, 2002, vol. 57, no. 9, pp. 1361–1452.10.1016/S0584-8547(02)00069-1 ↗
15. Nelms, S., Measurement of Cd in solution containing Mo using XSERIES 2 ICP-MS, Thermo Scientific Application Note: 40779-E04/07C. 2007.
16. Jarrett, J.M., Xiao, G., Caldwell, K.L., Henahan, D., Shakirova, G., and Jones, R.L., Eliminating molybdenum oxide interference in urine cadmium biomonitoring using ICP-DRC-MS, J. Anal. At. Spectrom., 2008, vol. 23, no. 7, pp. 962–967.10.1039/b801927d ↗
17. Kipphardt, H., Czerwensky, M., and Matschat, R., ICP-MS Analysis of high purity molybdenum used as SI-traceable standard of high metrological quality, J. Anal. At. Spectrom., 2005, vol. 20, no. 1, pp. 28–34.10.1039/b409973g ↗
18. Flem, B., Larsen, R.B., Grimstvedt, A., and Mansfeld, J., In situ analysis of trace elements in quartz by using laser ablation inductively coupled plasma mass spectrometry, Chem. Geol., 2002, vol. 182, nos. 2–4, pp. 237–247.10.1016/S0009-2541(01)00292-3 ↗
19. Koch, J., Feldmann, J., Hattendorf, B., Günther D., Engel, U., Jakubowski, N., Bolshov, M., Niemax, K., and Hergenröder, R., Trace element analysis of synthetic mono- and poly-crystalline CaF2 by ultraviolet laser ablation inductively coupled plasma mass spectrometry at 266 and 193 nm, Abstract Spectrochim. Acta, Part B, 2002, vol. 57, no. 6, pp. 1057–1070.10.1016/S0584-8547(02)00033-2 ↗
20. Chi, P.H., Ko, F.H., Hsu, C.T., Chen, H.L., Yang, C.K., Sun, Y.C., and Yang, M.H., Direct impurity analysis of semiconductor photoresist samples with laser ablation ICP-MS, J. Anal. At. Spectrom., 2002, vol. 17, no. 4, pp. 358–365.10.1039/b110070j ↗
21. Traub, H., Wälle, M., Koch, J., Panne, U., Matschat, R., Kipphardt, H., and Günther, D., Evaluation of different calibration strategies for the analysis of pure copper and zinc samples using femtosecond laser ablation ICP-MS, Anal. Bioanal. Chem., 2009, vol. 395, no. 5, pp. 1471–1480.10.1007/s00216-009-3061-9 ↗
22. Balcaen, L.I.L., Lenaerts, J., Moens, L., and Vanhaecke, F., Application of laser ablation inductively coupled plasma (dynamic reaction cell) mass spectrometry for depth profiling analysis of high-tech industrial materials, J. Anal. At. Spectrom., 2005, vol. 20, no. 5, pp. 417–423.10.1039/b412287a ↗
23. Li, F., Balazs, M.K., and Pong, R., Total dose measurement for ion implantation using laser ablation ICP-MS, J. Anal. At. Spectrom., 2000, vol. 15, no. 9, pp. 1139–1141.10.1039/b001796p ↗
24. Li, S., Hu, B., and Jiang, Z., Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry, J. Anal. At. Spectrom., 2004, vol. 19, no. 3, pp. 387–391.10.1039/b307780m ↗
25. Krushevska, A., Tan, S., Passer, M., and Liu, X.R., Advances in trace element analysis of silicon wafer surfaces by vapor phase decomposition (VPD) and inductively coupled plasma mass spectrometry (ICP-MS), J. Anal. At. Spectrom., 2000, vol. 15, no. 9, pp. 1211–1216.10.1039/b001578o ↗
26. Ferrero, E.J. and Posey, D., Improving the detection limits for vapor phase decomposition-inductively coupled plasma mass spectrometry (VPD-ICP-MS) analysis, J. Anal. At. Spectrom., 2002, vol. 17, no. 9, pp. 1194–1201.10.1039/b201759h ↗
27. O’Brien, S.E., Acon, B.W., Boulyga, S.F., Becker, J.S., Dietze, H.-J., and Montaser, A., Reduction of molecular ion interferences with hexapole collision cell in direct injection nebulization-inductively coupled plasma mass spectrometry, J. Anal. At. Spectrom., 2003, vol. 18, no. 3, pp. 230–238.10.1039/b209047n ↗
28. Nonose, N., Ohata, M., Narukawa, T., Hioki, A., and Chiba, K., Removal of isobaric interferences in isotope dilution analysis of vanadium in silicon nitride fine ceramics powder by DRC-ICP-MS, J. Anal. At. Spectrom., 2009, vol. 24, no. 3, pp. 310–319.10.1039/b812565a ↗
29. Porche, A.F., Kishi, Y., and Wolf, R.E., Analysis of silicon wafers using the ELAN DRC ICP-MS, At. Spectrosc., 2003, vol. 24, no. 2, pp. 42–45.
30. Zhang, A.D. and Liu, X.S., Determination of trace elements in high-purity palladium by inductively coupled plasma mass spectrometry using an internal standard method, Abstract Spectrosc. Lett., 2006, vol. 39, no. 5, pp. 447–455.10.1080/00387010600820080 ↗
31. Xie, H.L. and Nie, X.D., Determination of trace impurities in high-purity cadmium by high-resolution inductively coupled plasma mass spectrometry, Anal. Sci., 2006, vol. 22, no. 10, pp. 1371–1374.10.2116/analsci.22.1371 ↗
32. Xie, H.L., Nie, X.D., and Tang, Y.G., Direct determination of trace elements in high purity gallium by high resolution inductively coupled plasma mass spectrometry, Chin. J. Anal. Chem., 2006, vol. 34, pp. 1570–1574.10.1016/S1872-2040(07)60016-4 ↗
33. Xie, H.L., Huang, K.L., Nie, X.D., and Tang, Y.G., Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry, Abstract Rare Met., 2007, vol. 26, no. 3, pp. 286–293.10.1016/S1001-0521(07)60216-2 ↗
34. Lange, B., Recknagel, S., Czerwensky, M., Matschat, R., Michaelis, M., Peplinski, B., and Panne, U., Analysis of pure copper-a comparison of analytical methods, Microchim. Acta, 2008, vol. 160, nos. 1–2, pp. 97–107.10.1007/s00604-007-0849-1 ↗
35. Kozono, S. and Haraguchi, H., Determination of ultratrace impurity elements in high purity niobium materials by on-line matrix separation and direct injection/inductively coupled plasma mass spectrometry, Talanta, 2007, vol. 72, no. 5, pp. 1791–1799.10.1016/j.talanta.2007.02.021 ↗
36. He, M., Hu, B., Zeng, Y., and Jiang, Z., ICP-MS Direct determination of trace amounts of rare earth impurities in various rare earth oxides with only one standard series, J. Alloys Compd., 2005, vol. 390, nos. 1–2, pp. 168–174.10.1016/j.jallcom.2004.06.107 ↗
37. Kharitonov, P.S., Stepanov, A.I., Ramendik, G.I., and Karmannikov, V.P., Determination of rare elements impurities in high-purity neodymium oxide by inductively coupled plasma mass spectrometry method, Ind. Lab., Diagn. Mater., 2001, vol. 67, no. 8, pp. 18–20.
38. Pedreira, W.R., da Silva Queiroz, C.A., Abrão, A., and Pimentel M.M., Quantification of trace amounts of rare earth elements in high purity gadolinium oxide by sector field inductively coupled plasma mass spectrometry (ICP-MS), J. Alloys Compd., 2004, vol. 374, no. 1–2, pp. 129–132.10.1016/j.jallcom.2003.11.148 ↗
39. Zhernokleeva, K.V. and Baranovskaya, V.B., Analysis of pure scandium, yttrium, and their oxides using methods of inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry, Inorg. Mater., 2011, vol. 47, no. 15, pp. 1627–1634.10.1134/S0020168511150192 ↗
40. Cano Pavon, J.M., Vereda Alonso, E., Siles Cordero, M.T., García de Torres, A., and Lopez-Cepero, J.M., Use of spectroscopic techniques for the chemical analysis of biomorphic silicon carbide ceramics, Anal. Chim. Acta, 2005, vol. 528, no. 1, pp. 129–134.10.1016/j.aca.2004.09.090 ↗
41. Duan, T., Kang, J., Chen, H., and Zeng, X., Determination of ultra-trace concentrations of elements in high purity tellurium by inductively coupled plasma mass spectrometry after Fe(OH)3 coprecipitation, Spectrochim. Acta, Part B, 2003, vol. 58, no. 9, pp. 1679–1685.10.1016/S0584-8547(03)00142-3 ↗
42. Sahayam, A.C., Jiang, S.-J., and Wan, C.-C., Volatilization of in situ generated antimony trichloride using aqua regia vapors for the determination of ultra trace impurities in high-purity antimony using inductively coupled plasma-mass spectrometry, Anal. Chim. Acta, 2007, vol. 598, no. 2, pp. 214–218.10.1016/j.aca.2007.07.044 ↗
43. Ueng, R.-L., Sahayam, A.C., Jiang, S.-J., and Wan, C.-C., Microwave-assisted volatilization of chlorides of Ge and Se for the determination of trace impurities in high purity Ge and Se by ICP-MS, J. Anal. At. Spectrom., 2004, vol. 19, no. 5, pp. 681–684.10.1039/b400225n ↗
44. Karandashev, V.K., Bezrukov, L.B., Kornoukhov, V.N., Nosenko, S.V., Glavin, G.G., and Ovchinnikov S.V., Analysis of germanium and germanium dioxide samples by mass-spectrometry and atomic emission spectroscopy, J. Anal. Chem., 2009, vol. 64, no. 3, pp. 259–267.10.1134/S1061934809030095 ↗
45. Sahayam, A.C., Jiang, S.-J., and Wan, C.-C., Determination of ultra-trace impurities in high purity gallium arsenide by inductively coupled plasma mass spectrometry after volatilization of matrix, J. Anal. At. Spectrom., 2004, vol. 19, no. 3, pp. 407–409.10.1039/b312414m ↗
46. Hasegawa, S., Sato, K., Ide, K., Kobayashi, T., Igarashi, S., and Naito, K., Determination of trace elements in high purity iron by solid phase extraction/inductively coupled plasma mass spectrometry, Abstract J. Jpn. Inst. Met., 2000, vol. 64, no. 12, pp. 1212–1217.10.2320/jinstmet1952.64.12_1212 ↗
47. Xie, H.L., Nie, X.D., and Li, L.B., Determination of impurity elements in high-purity aluminium using inductively coupled plasma-mass spectrometry after matrix extraction and separation, Abstract Spectrosc. Spectral Anal., 2007, vol. 27, no. 1, pp. 169–172.
48. Karandashev, V.K., Turanov, A.N., and Nosenko, S.V., Analysis of molybdenum oxide by inductively coupled plasma atomic emission and mass spectrometry, J. Anal. Chem., 2011, vol. 66, no. 1, pp. 37–43.10.1134/S1061934811010059 ↗
49. Park, C.J., Kim, K.J., Cha, M.J., and Lee, D.S., Determination of boron in uniformly-doped silicon thin films by isotope dilution inductively coupled plasma mass spectrometry, Analyst, 2000, vol. 125, no. 3, pp. 493–497.10.1039/a909215c ↗
50. Fujimoto, K. and Shimura, M., Determination of trace amounts of elements in high-purity iron by ICP-MS after ion chromatographic separation using the cumulated bed of cation- and anion-exchange resin, Bunseki Kagaku, 2001, vol. 50, no. 3, pp. 175–182.10.2116/bunsekikagaku.50.175 ↗
51. Kozono, S., Takashi, R., and Haraguchi, H., Determination of ultratrace impurities in high purity tantalum materials by on-line anion exchange matrix separation and inductively coupled plasma mass spectrometry, Anal. Sci., 2000, vol. 16, no. 1, pp. 69–74.10.2116/analsci.16.69 ↗
52. Balarama Krishna, M.V., Shekhar, R., Karunasagar, D., and Arunachalam, J., Multi-element characterization of high purity cadmium using inductively coupled plasma quadrupole mass spectrometry and glow-discharge quadrupole mass spectrometry, Anal. Chim. Acta., 2000, vol. 408, nos. 1–2, pp. 199–207.10.1016/S0003-2670(99)00860-0 ↗
53. Kozono, S., Takahashi, S., and Haraguchi, H., Determination of boron in high-purity tantalum materials by on-line matrix separation/inductively coupled plasma mass spectrometry, Analyst, 2002, vol. 127, no. 7, pp. 930–934.10.1039/b201019b ↗
54. Kozono, S., Takahashi, S., and Haraguchi, H., Determination of trace phosphorus in high purity tantalum materials by inductively coupled plasma mass spectrometry subsequent to matrix separation with on-line anion exchange/coprecipitation, Anal. Bioanal. Chem., vol. 372, no. 4, pp. 542–548.10.1007/s00216-001-1145-2 ↗
55. Coedo, A.-G., Dorado, M.T., and Padilla, I. On-line ion-exchange matrix separation and inductively coupled plasma mass spectrometric determination of trace ipurities in high-purity aluminium, J. Anal. At. Spectrom., 2002, vol. 17, no. 5, pp. 502–506.10.1039/b109411b ↗
56. Pedreira, W.R., Sarkis, J.E.S., Rodrigues, C., Tomiyoshi, I.A., da Silva Queiroz, C.A., and Abrão, A., Determination of trace amounts of rare earth elements in high pure lanthanum oxide by sector field inductively coupled plasma mass spectrometry (HR ICP-MS) and high-performance liquid chromatography (HPLC) techniques, J. Alloys. Compd., 2002, vol. 344, nos. 1–2, pp. 17–20.10.1016/S0925-8388(02)00297-9 ↗
57. Kozono, S. and Haraguchi, H., Determination of trace iron in indium phosphide wafer by on-line matrix separation and inductively coupled plasma mass spectrometry, Anal. Chim. Acta, 2003, vol. 482, no. 2, pp. 189–196.10.1016/S0003-2670(03)00255-1 ↗
58. Qin, S., Jiang, Z., Hu, B., Quin, Y., and Hu, S., HPLC combined with ICP-MS for the determination of trace amounts of rare earth impurities in high-purity La2O3 by using 2-ethylhexylhydrogen-2-ethylhexylphosphonate resin as a stationary phase, Fresen. J. Anal. Chem., 2000, vol. 367, no. 3, pp. 250–253.10.1007/s002160000334 ↗
59. Pedreira, W.R., Sarkis, J.E.S., Rodrigues, C., Tomiyoshi, I.A., da Silva Queiroz, C.A., and Abrão, A., Determination of trace amounts of rare earth elements in highly pure praseodymium oxide by double focusing inductively coupled plasma mass spectrometry and highperformance liquid chromatography, J. Alloys. Compd., 2001, vols. 323–324, pp. 49–52.10.1016/S0925-8388(01)00997-5 ↗
60. Pedreira, W.R., Sarkis, J.E.S., da Silva Queiroz, C.A., Rodrigues, C., Tomiyoshi, I.A., and Abrão, A., Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques, J. Solid State Chem. 2003, vol. 171, nos. 1–2, pp. 3–6.10.1016/S0022-4596(02)00003-8 ↗
61. Xinquan Zhang, Jinglei Liu, Yong Yi, Yonglin Liu, Xiang Li, Yaqin Su, and Ping Lin, Determination of rare earth impurities in high purity samarium oxide using inductively coupled plasma mass spectrometry after extraction chromatographic separation, Int. J. Mass Spectrom., 2007, vol. 260, no. 1, pp. 57–66.10.1016/j.ijms.2006.07.003 ↗
62. Pedreira, W.R., da Silva Queiroz, C.A., Abrão, A., Rocha, S.M., de Vasconcellos, M.E., Boaventura, G.R., and Pimentel, M.M., Trace amounts of rare earth elements in high purity samarium oxide by sector field inductively coupled plasma mass spectrometry after separation by HPLC, J. Alloys. Compd., 2006, vol. 418, nos. 1–2, pp. 247–250.10.1016/j.jallcom.2005.10.081 ↗
63. Zhang, X., Yi, Y., Liu, Y., Li, X., Liu, J., Jiang, Y., and Su, Y., Direct determination of rare earth impurities in High Purity Erbium Oxide Dissolved in Nitric Acid By Inductively Coupled Plasma Mass Spectrometry, Anal. Chim. Acta, 2006, vol. 555, no. 1, pp. 57–62.10.1016/j.aca.2005.08.055 ↗
64. Karandashev, V.K., Zhernokleeva, K.V., Turanov, A.N., Baranovskaya, V.B., and Karpov, Yu.A., Determination of admixtures of high-melting metals in rare-earth metals and their compounds, J. Anal. Chem., 2012, vol. 67, no. 4, pp. 340–348.10.1134/S1061934812040107 ↗
65. Grinberg, P., Willie, S., and Sturgeon, R.E., Determination of thorium and uranium in ultrapure lead by inductively coupled plasma mass spectrometry, Anal. Chem., 2005, vol. 77, no. 8, pp. 2432–2436.10.1021/ac048539t ↗
66. Koyama, M. and Tanaka, T., ICP-MS determination of trace amounts of zinc, copper, lead and bismuth in high-purity aluminum after electrolytic separation, Abstract Bunseki Kagaku, 2002, vol. 51, no. 9, pp. 815–820.10.2116/bunsekikagaku.51.815 ↗
67. Hoppe, E.W., Aalseth, C.E., Brodzinski, R., Day, A.R., Farmer, O.T., Hossbach, T.W., McIntyre, J.I., Miley, H.S., Mintzer, E.E., Seifert, A., Smart, J.E., and Warren, G.A., Use of electrodeposition for sample preparation and rejection rate prediction for assay of electroformed ultra high purity copper for 232Th and 238U prior to inductively coupled plasma mass spectrometry (ICP/MS), J. Radioanal. Nucl. Chem., 2008, vol. 277, no. 1, pp. 103–110.10.1007/s10967-008-0716-5 ↗
68. Surikov, V.T., Acidic dissolution of silicon and its compounds for analysis by inductively coupled plasma-mass spectrometry method, Anal. Kontol., 2008, vol. 12, no. 3–4, pp. 93–100.
69. Hsiao, P.-K., Jiang, S.-J., and Sahayamb, A.C., Determination of trace elements in silicon powder using slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry, J. Anal. At. Spectrom., 2011, vol. 26, no. 3, pp. 586–592.10.1039/c0ja00203h ↗
70. Resano, M., Vanhaecke, F., and de Loos-Vollebregt M.T.C., Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry-A critical review with focus on solid sampling and slurry analysis, J. Anal. At. Spectrom., 2008, vol. 23, no. 11, pp. 1450–1475.10.1039/b807756h ↗
71. Shelpakova, I.R. and Shaverina A.V., The determination of impurities in silicon (review), Anal. Kontrol., 2011, vol. 15, no. 2, pp. 141–150.
72. Bol’shov, M.A., Karandashev, V.K., Tsisin, G.I., and Zolotov, Yu.A., Flow methods for the determination of elements in solutions based on sorption preconcentration and inductively coupled plasma mass spectrometry, J. Anal. Chem., 2011, vol. 66, no. 6, pp. 548–564.10.1134/S1061934811060037 ↗