journal article·2008-02-25

Bearing capacity of two interfering footings

Jyant Kumar, K. M. Kouzer

Publisher page

Abstract

Abstract By using an upper bound limit analysis in conjunction with finite elements and linear programming, the ultimate bearing capacity of two interfering rough strip footings, resting on a cohesionless medium, was computed. Along all the interfaces of the chosen triangular elements, velocity discontinuities were employed. The plastic strains were incorporated using an associated flow rule. For different clear spacing (S) between the two footings, the efficiency factor (ξγ) was determined, where ξγ is defined as the ratio of the failure load for a strip footing of given width in the presence of the other footing to that of a single isolated strip footing having the same width. The value of ξγ at S/B = 0 becomes equal to 2.0, and the maximum ξγ occurs at S/B = Scr/B. For S/B⩽Scr/B, the ultimate failure load for a footing becomes almost half that of an isolated footing having width (2B + S), and the soil mass below and in between the two footings deforms mainly in the downward direction. In contrast, for S/B>Scr/B, ground heave was noticed along both the sides of the footing. As compared to the available theories, the analysis provides generally lower values of ξγ for S/B>Scr/B. Copyright © 2007 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Geotechnical Engineering and Underground Structures · Geotechnical Engineering and Analysis · Geotechnical Engineering and Soil Stabilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. 10.1680/geot.1962.12.1.1510.1680/geot.1962.12.1.15 ↗
2. Bearing capacity of three closely‐spaced footings on sand10.1680/geot.1984.34.2.173 ↗
3. 10.1061/(ASCE)1532-3641(2007)7:1(53)10.1061/(ASCE)1532-3641(2007)7:1(53) ↗
4. WestJM StuartJG.Oblique loading resulting from interference between surface footings on sand. Proceedings of the 6th International Conference on Soil Mechanics and Foundation Engineering Montreal vol. 2 1965;214–217.
5. Interference of surface footings on sand
6. 10.3208/sandf1972.23.110.3208/sandf1972.23.1 ↗
7. 10.1061/(ASCE)1090-0241(2003)129:7(660)10.1061/(ASCE)1090-0241(2003)129:7(660) ↗
8. Upper bound limit analysis using discontinuous velocity fields10.1016/0045-7825(95)00868-1 ↗
9. 10.1016/0045-7825(80)90055-910.1016/0045-7825(80)90055-9 ↗
10. Chen WF · 1975
11. Chen WF · 1990
12. Effect of footing roughness on bearing capacity factor N γ
13. Calculation of bearing capacity factor N γ using numerical limit analysis10.1061/(ASCE)1090-0241(2003)129:6(468) ↗
14. Numerical limit analysis solutions for the bearing capacity factor N γ10.1016/j.ijsolstr.2004.08.002 ↗
15. 10.1002/nme.131410.1002/nme.1314 ↗
16. 10.1002/nme.156710.1002/nme.1567 ↗
17. 10.1016/j.ijsolstr.2006.06.03610.1016/j.ijsolstr.2006.06.036 ↗