Stretchable ionic–electronic bilayer hydrogel electronics enable in situ detection of solid-state epidermal biomarkers
Source abstract
Abstract
Continuous and in situ detection of biomarkers in biofluids (for example, sweat) can provide critical health data but is limited by biofluid accessibility. Here we report a sensor design that enables in situ detection of solid-state biomarkers ubiquitously present on human skin. We deploy an ionic-electronic bilayer hydrogel to facilitate the sequential dissolution, diffusion and electrochemical reaction of solid-state analytes. We demonstrate continuous monitoring of water-soluble analytes (for example, solid lactate) and water-insoluble analytes (for example, solid cholesterol) with ultralow detection limits of 0.51 and 0.26 nmol cm-2, respectively. Additionally, the bilayer hydrogel electrochemical interface reduces motion artefacts by a factor of three compared with conventional liquid-sensing electrochemical interfaces. In a clinical study, solid-state epidermal biomarkers measured by our stretchable wearable sensors showed a high correlation with biomarkers in human blood and dynamically correlated with physiological activities. These results present routes to universal platforms for biomarker monitoring without the need for biofluid acquisition.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Advanced Chemical Sensor Technologies · Tactile and Sensory Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Trumbo, P., Schlicker, S., Yates, A. A. & Poos, M. Dietary reference intakes for energy, carbohydrate, fiber, fat, fatty acids, cholesterol, protein and amino acids. J. Am. Diet. Assoc. 102, 1621–1630 (2002).10.1016/S0002-8223(02)90346-9 ↗
2. Wang, T. J. et al. Metabolite profiles and the risk of developing diabetes. Nat. Med. 17, 448–453 (2011).10.1038/nm.2307 ↗
3. Akbaraly, T. et al. Association of circulating metabolites with healthy diet and risk of cardiovascular disease: analysis of two cohort studies. Sci. Rep. 8, 8620 (2018).10.1038/s41598-018-26441-1 ↗
4. Kim, J., Campbell, A. S., de Ávila, B. E.-F. & Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 37, 389–406 (2019).10.1038/s41587-019-0045-y ↗
5. Yang, Y. & Gao, W. Wearable and flexible electronics for continuous molecular monitoring. Chem. Soc. Rev. 48, 1465–1491 (2019).10.1039/C7CS00730B ↗
6. Gao, W. et al. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature 529, 509–514 (2016).10.1038/nature16521 ↗
7. Yang, Y. et al. A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat. Nat. Biotechnol. 38, 217–224 (2020).10.1038/s41587-019-0321-x ↗
8. Koh, A. et al. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat. Sci. Transl. Med. 8, 366ra165 (2016).
9. Sempionatto, J. R. et al. An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers. Nat. Biomed. Eng. 5, 737–748 (2021).10.1038/s41551-021-00685-1 ↗
10. Kim, J. et al. A skin‐interfaced, miniaturized microfluidic analysis and delivery system for colorimetric measurements of nutrients in sweat and supply of vitamins through the skin. Adv. Sci. 9, 2103331 (2022).10.1002/advs.202103331 ↗
11. Wang, M. et al. A wearable electrochemical biosensor for the monitoring of metabolites and nutrients. Nat. Biomed. Eng. 6, 1225–1235 (2022).10.1038/s41551-022-00916-z ↗
12. Andersson, A., Chen, Q., Groop, L., Bülow, L. & Xie, B. Continuous and simultaneous determination of venous blood metabolites. Talanta 171, 270–274 (2017).10.1016/j.talanta.2017.05.010 ↗
13. Park, S. M. et al. A mountable toilet system for personalized health monitoring via the analysis of excreta. Nat. Biomed. Eng. 4, 624–635 (2020).10.1038/s41551-020-0534-9 ↗
14. Chu, M. X. et al. Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta 83, 960–965 (2011).10.1016/j.talanta.2010.10.055 ↗
15. Jin, H., Huynh, T. P. & Haick, H. Self-healable sensors based nanoparticles for detecting physiological markers via skin and breath: toward disease prevention via wearable devices. Nano Lett. 16, 4194–4202 (2016).10.1021/acs.nanolett.6b01066 ↗
16. Kahn, N., Lavie, O., Paz, M., Segev, Y. & Haick, H. Dynamic nanoparticle-based flexible sensors: diagnosis of ovarian carcinoma from exhaled breath. Nano Lett. 15, 7023–7028 (2015).10.1021/acs.nanolett.5b03052 ↗
17. Ledger, P. W. Skin biological issues in electrically enhanced transdermal delivery. Adv. Drug Deliv. Rev. 9, 289–307 (1992).10.1016/0169-409X(92)90027-N ↗
18. Guffey, J. S., Rutherford, M. J., Ayne, W. & Phillips, C. Skin pH changes associated with iontophoresis. J. Orthop. Sports Phys. Ther. 29, 656–660 (1999).10.2519/jospt.1999.29.11.656 ↗
19. Roustit, M., Blaise, S. & Cracowski, J.-L. Trials and tribulations of skin iontophoresis in therapeutics. Br. J. Clin. Pharm. 77, 63–71 (2014).10.1111/bcp.12128 ↗
20. Carson, J. A. S. et al. Dietary cholesterol and cardiovascular risk: a science advisory from the American Heart Association. Circulation 141, e39–e53 (2020).
21. Pappas, A. Epidermal surface lipids. Dermatoendocrinol 1, 72–76 (2009).10.4161/derm.1.2.7811 ↗
22. Attanà, P. et al. Lactate and lactate clearance in acute cardiac care patients. Eur. Heart J. Acute Cardiovasc Care 1, 115–121 (2012).10.1177/2048872612451168 ↗
23. Cunningham, D. D. & Young, D. F. Measurements of glucose on the skin surface, in stratum corneum and in transcutaneous extracts: implications for physiological sampling. Clin. Chem. Lab. Med. 41, 1224–1228 (2003).10.1515/CCLM.2003.187 ↗
24. Rivnay, J. et al. Structural control of mixed ionic and electronic transport in conducting polymers. Nat. Commun. 7, 11287 (2016).10.1038/ncomms11287 ↗
25. Lee, I., Kim, G. W., Yang, M. & Kim, T.-S. Simultaneously enhancing the cohesion and electrical conductivity of PEDOT:PSS conductive polymer films using DMSO additives. ACS Appl. Mater. Interfaces 8, 302–310 (2016).10.1021/acsami.5b08753 ↗
26. Rathee, K., Dhull, V., Dhull, R. & Singh, S. Biosensors based on electrochemical lactate detection: a comprehensive review. Biochem. Biophys. Rep. 5, 35–54 (2016).
27. Pluen, A., Netti, P. A., Jain, R. K. & Berk, D. A. Diffusion of macromolecules in agarose gels: comparison of linear and globular configurations. Biophys. J. 77, 542–552 (1999).10.1016/S0006-3495(99)76911-0 ↗
28. Zhang, Y., Xu, Z., Zhao, Y. & Zhang, X. Ab initio molecular dynamics simulation study of dissociation electron attachment to lactic acid and isomer. Sci. Rep. 9, 19532 (2019).
29. Liu, Y. et al. Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation. Nat. Biomed. Eng. 3, 58–68 (2019).10.1038/s41551-018-0335-6 ↗
30. Bianchi, M. et al. Scaling of capacitance of PEDOT:PSS: volume vs. area. J. Mater. Chem. C 8, 11252–11262 (2020).10.1039/D0TC00992J ↗
31. Driscoll, N. et al. MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation. Sci. Transl. Med. 13, eabf8629 (2021).10.1126/scitranslmed.abf8629 ↗
32. Guo, M. et al. A highly stretchable, ultra-tough, remarkably tolerant, and robust self-healing glycerol-hydrogel for a dual-responsive soft actuator. J. Mater. Chem. A 7, 25969–25977 (2019).10.1039/C9TA10183G ↗
33. Håkansson, A. et al. Effect of (3-glycidyloxypropyl)trimethoxysilane (GOPS) on the electrical properties of PEDOT:PSS films. J. Polym. Sci. B 55, 814–820 (2017).10.1002/polb.24331 ↗
34. Li, L. H., Dutkiewicz, E. P., Huang, Y. C., Zhou, H. B. & Hsu, C. C. Analytical methods for cholesterol quantification. J. Food Drug Anal. 27, 375–386 (2019).10.1016/j.jfda.2018.09.001 ↗
35. Zhang, W., Guo, C., Jiang, K., Ying, M. & Hu, X. Quantification of lactate from various metabolic pathways and quantification issues of lactate isotopologues and isotopmers. Sci. Rep. 7, 8489 (2017).
36. Kim, D.-H. et al. Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics. Nat. Mater. 9, 511–517 (2010).10.1038/nmat2745 ↗
37. Zhang, S. et al. On-skin ultrathin and stretchable multifunctional sensor for smart healthcare wearables. npj Flex. Electron. 6, 11 (2022).10.1038/s41528-022-00140-4 ↗
38. Wang, C., Yokota, T. & Someya, T. Natural biopolymer-based biocompatible conductors for stretchable bioelectronics. Chem. Rev. 121, 2109–2146 (2021).10.1021/acs.chemrev.0c00897 ↗
39. Lee, Y.-Y. et al. Growth mechanism of strain-dependent morphological change in PEDOT:PSS films. Sci. Rep. 6, 25332 (2016).
40. Lademann, J., Jacobi, U., Surber, C., Weigmann, H.-J. & Fluhr, J. W. The tape stripping procedure—evaluation of some critical parameters. Eur. J. Pharm. Biopharm. 72, 317–323 (2009).10.1016/j.ejpb.2008.08.008 ↗
41. Sjövall, P. et al. Imaging the distribution of skin lipids and topically applied compounds in human skin using mass spectrometry. Sci. Rep. 8, 16683 (2018).10.1038/s41598-018-34286-x ↗
42. Petersen, L. J. Interstitial lactate levels in human skin at rest and during an oral glucose load: a microdialysis study. Clin. Physiol. 19, 246–250 (1999).10.1046/j.1365-2281.1999.00174.x ↗
43. Chen, T., Buckley, M., Cohen, I., Bonassar, L. & Awad, H. A. Insights into interstitial flow, shear stress, and mass transport effects on ECM heterogeneity in bioreactor-cultivated engineered cartilage hydrogels. Biomech. Model Mechanobiol. 11, 689–702 (2012).10.1007/s10237-011-0343-x ↗
44. Trapani, L., Segatto, M. & Pallottini, V. Regulation and deregulation of cholesterol homeostasis: the liver as a metabolic “power station”. World J. Hepatol. 4, 184 (2012).10.4254/wjh.v4.i6.184 ↗
45. Wu-Pong, S., Elias, P. M. & Feingold, K. R. Influence of altered serum cholesterol levels and fasting on cutaneous cholesterol synthesis. J. Invest. Dermatol. 102, 799–802 (1994).10.1111/1523-1747.ep12378556 ↗
46. Feneberg, R. et al. Synchronous fluctuations of blood insulin and lactate concentrations in humans. J. Clin. Endocrinol. Metab. 84, 220–227 (1999).
47. Lian, X. et al. Enzyme–MOF (metal–organic framework) composites. Chem. Soc. Rev. 46, 3386–3401 (2017).10.1039/C7CS00058H ↗
48. Jumper, J. et al. Highly accurate protein structure prediction with AlphaFold. Nature 596, 583–589 (2021).10.1038/s41586-021-03819-2 ↗