journal article·2024-10-12Open access

Angle Sensor for Minimally Invasive Surgical Robot Based on Surface Plasmon Resonance with Kretschmann Prisms

Heya Zheng, Yanpei Xu, Jinhong Pan, Meng Sun, Qi Wang

Plasmonics· Volume 20· Issue 6

Abstract

This study proposes a bimetallic Ag-Au sensor through a comparative analysis with traditional Ag-only membrane sensors and Au-only membrane SPR sensors. Innovative use of SPR sensors for angular change measurement, especially in minimally invasive robotic surgery in medicine. The research findings indicate that the Ag film sensor exhibits the highest sensitivity, while the bimetallic Ag-Au sensor demonstrates superior sensitivity compared to the Au-only sensor. Furthermore, the stability of the bimetallic Ag-Au sensor surpasses that of the Ag-only sensor. After evaluating the performance parameters based on experimental and simulation results, the sensor with 40 nm Ag and 10 nm Au film thickness is identified as the optimal design. Experimentally verified, this configuration yielded the best sensing performance, with a sensitivity of 628.95 for changes in folding angle. This represents a 275.64% improvement over the pure Au sensor and a 210.43% enhancement over the pure Ag sensor in terms of sensitivity for angle changes.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Photonic and Optical Devices · Micro and Nano Robotics · Orbital Angular Momentum in Optics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Ferrell T, Callcott T, Warmack R (1985) Plasmons and surfaces: electrons oscillating on a metal surface sometimes behave collectively like a single quantum of energy, or plasmon, with surprising effects and some ingenious applications. Am Sci 73(4):344–353
2. Dostálek J (2006) Rich information optical biosensor based on surface plasmon resonance
3. Daghestani HN, Day BW (2010) Theory and applications of surface plasmon resonance, resonant mirror, resonant waveguide grating, and dual polarization interferometry biosensors. Sensors. 10(11):9630–964610.3390/s101109630 ↗
4. Yesudasu V, Pradhan HS, Pandya RJ (2021) Recent progress in surface plasmon resonance based sensors: a comprehensive review. Heliyon. 7(3)10.1016/j.heliyon.2021.e06321 ↗
5. Ropers C, Neacsu C, Elsaesser T, Albrecht M, Raschke M, Lienau C (2007) Grating-coupling of surface plasmons onto metallic tips: a nanoconfined light source. Nano Lett 7(9):2784–278810.1021/nl071340m ↗
6. Shalabney A, Abdulhalim I (2011) Sensitivity-enhancement methods for surface plasmon sensors. Laser & Photonics Reviews. 5(4):571–60610.1002/lpor.201000009 ↗
7. Zalyubovskiy SJ, Bogdanova M, Deinega A, Lozovik Y, Pris AD, An KH, Hall WP, Potyrailo RA (2012) Theoretical limit of localized surface plasmon resonance sensitivity to local refractive index change and its comparison to conventional surface plasmon resonance sensor. JOSA A. 29(6):994–100210.1364/JOSAA.29.000994 ↗
8. Bandari N, Dargahi J, Packirisamy M (2019) Tactile sensors for minimally invasive surgery: a review of the state-of-the-art, applications, and perspectives. Ieee Access. 8:7682–770810.1109/ACCESS.2019.2962636 ↗
9. Darzi A, Munz Y (2004) The impact of minimally invasive surgical techniques. Annu Rev Med 55:223–23710.1146/annurev.med.55.091902.105248 ↗
10. Burschka D, Corso JJ, Dewan M, Lau W, Li M, Lin H, Marayong P, Ramey N, Hager GD, Hoffman B et al (2005) Navigating inner space: 3-d assistance for minimally invasive surgery. Robot Auton Syst 52(1):5–2610.1016/j.robot.2005.03.013 ↗
11. Alam IS, Steinberg I, Vermesh O, Berg NS, Rosenthal EL, Dam GM, Ntziachristos V, Gambhir SS, Hernot S, Rogalla S (2018) Emerging intraoperative imaging modalities to improve surgical precision. Mol Imag Biol 20:705–71510.1007/s11307-018-1227-6 ↗
12. Orekhov A, Abah C, Simaan N (2018) Snake-like robots for minimally invasive, single-port, and intraluminal surgeries. The encyclopedia of medical robotics. 1:203–24310.1142/9789813232266_0008 ↗
13. Dudai M, Ramshow B (2018) 26th International Congress of the European Association for Endoscopic Surgery (EAES), London, United Kingdom, 30 May-1 June 2018: Additional oral & poster presentations. Surg Endosc 32:615–66910.1007/s00464-019-06728-8 ↗
14. Henselmans P (2020) Mechanical snakes: path-following instruments for minimally invasive surgery
15. Banks JL (2001) Design and control of an anthropomorphic robot finger with multi-point tactile sensation. PhD thesis, Massachusetts Institute of Technology
16. Menon S (2017) Models, analyses, tools, and experiments to characterize human motor control and coordination. PhD thesis, Stanford University
17. Vitiello V, Lee S-L, Cundy TP, Yang G-Z (2012) Emerging robotic platforms for minimally invasive surgery. IEEE Rev Biomed Eng 6:111–12610.1109/RBME.2012.2236311 ↗
18. Bauzano E, Garcia-Morales I, Saz-Orozco P, Fraile JC, Muñoz VF (2013) A minimally invasive surgery robotic assistant for HALS-SILS techniques. Comput Methods Programs Biomed 112(2):272–28310.1016/j.cmpb.2013.01.017 ↗
19. Banach A, Leibrandt K, Grammatikopoulou M, Yang G-Z (2019) Active contraints for tool-shaft collision avoidance in minimally invasive surgery. In: 2019 International Conference on Robotics and Automation (ICRA), pp. 1556–1562 . IEEE10.1109/ICRA.2019.8794147 ↗
20. Tulloh B, Lee D (2007) Foundations of operative surgery: an introduction to surgical techniques. Oxford University Press (UK), ???10.1093/oso/9780199228669.001.0001 ↗
21. Zhu R, Zhou Z (2004) A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package. IEEE Trans Neural Syst Rehabil Eng 12(2):295–30210.1109/TNSRE.2004.827825 ↗
22. Kang H, Wen JT (2001) Robotic assistants aid surgeons during minimally invasive procedures. IEEE Eng Med Biol Mag 20(1):94–10410.1109/51.897832 ↗
23. Thananjeyan B, Tanwani A, Ji J, Fer D, Patel V, Krishnan S, Goldberg K (2019) Optimizing robot-assisted surgery suture plans to avoid joint limits and singularities. In: 2019 International Symposium on Medical Robotics (ISMR), pp 1–7. IEEE10.1109/ISMR.2019.8710194 ↗
24. Lu B, Chu HK, Huang K, Cheng L (2018) Vision-based surgical suture looping through trajectory planning for wound suturing. IEEE Trans Autom Sci Eng 16(2):542–55610.1109/TASE.2018.2840532 ↗
25. Özpirin M, Ebil Ö (2018) Transparent block copolymer thin films for protection of optical elements via chemical vapor deposition. Thin Solid Films 660:391–39810.1016/j.tsf.2018.06.044 ↗
26. Jiu J, Wang J, Sugahara T, Nagao S, Nogi M, Koga H, Suganuma K, Hara M, Nakazawa E, Uchida H (2015) The effect of light and humidity on the stability of silver nanowire transparent electrodes. RSC Adv 5(35):27657–2766410.1039/C5RA02722E ↗
27. Azani M-R, Hassanpour A, Torres T (2020) Benefits, problems, and solutions of silver nanowire transparent conductive electrodes in indium tin oxide (ITO)-free flexible solar cells. Adv Energy Mater 10(48):200253610.1002/aenm.202002536 ↗
28. Bai J, Li J, Wang X, Zhou Q, Ni K, Li X (2022) A new method to measure spectral reflectance and film thickness using a modified chromatic confocal sensor. Opt Lasers Eng 154:10701910.1016/j.optlaseng.2022.107019 ↗
29. Tien C-L, Lin H-Y, Su S-H (2018) High sensitivity refractive index sensor by d-shaped fibers and titanium dioxide nanofilm. Advances in Condensed Matter Physics. 2018(1):2303740
30. Poksinski M, Arwin H (2003) In situ monitoring of metal surfaces exposed to milk using total internal reflection ellipsometry. Sens Actuators, B Chem 94(3):247–25210.1016/S0925-4005(03)00382-4 ↗
31. Chen Y, Zhang D, Zhu L, Fu Q, Wang R, Wang P, Ming H, Badugu R, Lakowicz JR (2014) Effect of metal film thickness on Tamm plasmon-coupled emission. Phys Chem Chem Phys 16(46):25523–2553010.1039/C4CP04031G ↗
32. Chang J-P, Tsai C-M, Weng J-H, Han P (2024) Refractive index and dispersion measurement principle with polarization change in total internal reflection. In: Photonics, vol 11, p 505. MDPI10.3390/photonics11060505 ↗
33. Babu RS, Colenso HR, Gouws GJ, Auguié B, Moore CP (2023) Performance enhancement of an Ag-Au bimetallic SPR sensor: a theoretical and experimental study. IEEE Sens J 23(10):10420–1042810.1109/JSEN.2023.3265896 ↗
34. Liu L, Liu Z, Zhang Y, Liu S (2022) Multi-channel optical fiber surface plasmon resonance sensor with narrow FWHM, high figure of merit, and wide detection range. Plasmonics 17(5):2235–224410.1007/s11468-022-01713-9 ↗
35. Espinosa-Sánchez Y, Luna-Moreno D, Rodríguez-Delgado M, Sánchez-Álvarez A (2017) Determination of optical parameters of organic and inorganic thin films using both surface plasmon resonance and Abelès-Brewster methods. Optik 142:426–43510.1016/j.ijleo.2017.05.090 ↗
36. Mukhtar WM, Halim RM, Hassan H (2017) Optimization of SPR signals: monitoring the physical structures and refractive indices of prisms. In: EPJ Web of conferences, vol 162, p 01001. EDP Sciences10.1051/epjconf/201716201001 ↗
37. Ong BH, Yuan X, Tjin SC, Zhang J, Ng HM (2006) Optimised film thickness for maximum evanescent field enhancement of a bimetallic film surface plasmon resonance biosensor. Sens Actuators, B Chem 114(2):1028–103410.1016/j.snb.2005.07.064 ↗
38. Ashrafi T, Mohanty G (2022) Sensitivity calculation for different prism material based surface plasmon resonance sensor: a comparative study. In: Journal of physics: conference series, vol 2267, p. 012089. IOP Publishing10.1088/1742-6596/2267/1/012089 ↗
39. Mukhtar WM, Halim RM, Hassan H (2017) Optimization of SPR signals: monitoring the physical structures and refractive indices of prisms. In: EPJ Web of conferences, vol 162, p 01001. EDP Sciences10.1051/epjconf/201716201001 ↗
40. Riswan M, Widianto E, Istiqomah NI, Driyo C, Arifin M, Santoso I, Suharyadi E (2024) Tuning optical properties of au thin film using electric field for surface plasmon resonance biosensor application. Opt Mater 150:11522110.1016/j.optmat.2024.115221 ↗
41. Lam W, Chu L, Wong C, Zhang Y (2005) A surface plasmon resonance system for the measurement of glucose in aqueous solution. Sens Actuators, B Chem 105(2):138–14310.1016/j.snb.2004.04.088 ↗
42. Steiner M-S, Duerkop A, Wolfbeis OS (2011) Optical methods for sensing glucose. Chem Soc Rev 40(9):4805–483910.1039/c1cs15063d ↗
43. Tan C-Y, Huang Y-X (2015) Dependence of refractive index on concentration and temperature in electrolyte solution, polar solution, nonpolar solution, and protein solution. Journal of Chemical & Engineering Data. 60(10):2827–283310.1021/acs.jced.5b00018 ↗