journal article·2018-04-01Open access

A contact-force regulated photoplethysmography (PPG) platform

Jai Kyoung Sim, Bongyoung Ahn, Il Doh

AIP Advances· Volume 8· Issue 4

Abstract

A photoplethysmography (PPG) platform integrated with a miniaturized force-regulator is proposed in this study. Because a thermo-pneumatic type regulator maintains a consistent contact-force between the PPG probe and the measuring site, a consistent and stable PPG signal can be obtained. We designed and fabricated a watch-type PPG platform with an overall size of 35 mm × 19 mm. In the PPG measurement on the radial artery wrist while posture of the wrist is changed to extension, neutral, or flexion, regulation of the contact-force provides consistent PPG measurements for which the variations in the PPG amplitude (PPGA) was 7.2 %. The proposed PPG platform can be applied to biosignal measurements in various fields such as PPG-based ANS monitoring to estimate nociception, sleep apnea syndrome, and psychological stress.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Heart Rate Variability and Autonomic Control

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Center for Medical Convergence Metrology, Korea Research Institute of Standards and Science (KRISS) 1 , 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea

Department of Medical Physics, University of Science and Technology (UST) 2 , 217 Gajeong-ro, Yuseong-gu, Daejeon 34113, Repubic of Korea

Funding

Korea Research Institute of Standards and Science · National Research Foundation of Korea

References (32)

Show source-provided references
1. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/r01 ↗
2. Photoplethysmography and nociception: Review article10.1111/j.1399-6576.2009.02026.x ↗
3. Assessing pain objectively: The use of physiological markers10.1111/anae.13018 ↗
4. The variability of the photoplethysmographic signal—A potential method for the evaluation of the autonomic nervous system10.1088/0967-3334/19/1/008 ↗
5. Monitoring the nociception-anti-nociception balance10.1016/j.bpa.2013.06.007 ↗
6. Effect of pain on autonomic nervous system indices derived from photoplethysmography in healthy volunteers10.1093/bja/aes001 ↗
7. Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children10.1016/j.bspc.2007.12.002 ↗
8. Developing a monitoring psychological stress index system via photoplethysmography10.1007/s10015-011-0976-y ↗
9. 2014
10. Effect of mental stress throughout the day on cardiac autonomic control10.1016/0301-0511(94)90024-8 ↗
11. Sensor factors influencing photoplethysmography
12. Photoplethysmographic signal waveform index for detection of increased arterial stiffness10.1088/0967-3334/35/10/2027 ↗
13. Wearable photoplethysmographic sensors—Past and present10.3390/electronics3020282 ↗
14. Effects of different contacting pressure on the transfer function between finger photoplethysmographic and radial blood pressure waveforms10.1177/0954411910396288 ↗
15. Reflectance forehead pulse oximetry: Effects of contact pressure during walking
16. Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness10.1117/1.jbo.18.2.027004 ↗
17. Theoretical study on the effect of sensor contact force on pulse transit time10.1109/tbme.2007.900815 ↗
18. The effect of contacting force on photoplethysmographic signals10.1088/0967-3334/25/5/020 ↗
19. Artifact-resistant, power-efficient design of finger-ring plethysmographic sensors. I. Design and analysis
20. Development of oriental-western fusion patient monitor by using the clip-type pulsimeter equipped with a Hall sensor, the electrocardiograph, and the photoplethysmograph10.4283/jkms.2013.23.4.135 ↗
21. Design and prototyping a wristband-type wireless photoplethsmograph device for heart rate variability signal analysis
22. Wearable medical systems for p-health10.1109/RBME.2008.2008248 ↗
23. BioWatch: A non-invasive wrist-based blood pressure monitor that incorporates training techniques for posture and subject variability
24. Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor
25. Photoplethysmographic logger with contact force and hydrostatic pressure monitoring
26. A thermal peripheral blood flowmeter with contact force compensation10.1088/0960-1317/22/12/125014 ↗
27. Method and apparatus for assessing hemodynamic parameters within the circulatory system of a living subject
28. Compensation of PPG signal distortion due to pressure using FSR sensors
29. Wearable sweat rate sensors for human thermal comfort monitoring
30. Braille dot display module with a PDMS membrane driven by a thermopneumatic actuator10.1016/j.sna.2008.10.002 ↗
31. Portable sweat rate sensors integrated with air ventilation actuators10.1016/j.snb.2016.04.137 ↗
32. Droplet-volume-adjustable microinjectors using a digital combination of multiple current paths connected to single microheater10.1109/jmems.2009.2020464 ↗