The influences of geometrical parameters on the failure response of two serial pinned/bolted composite joints
Source abstract
Abstract
In this study, the influences of geometrical parameters on the failure response of two serial pinned/bolted composite joints were analysed. The tested composite material consisted of epoxy matrix and glass fibres. It was oriented as [0°/ 0°/ 60°/ 60°] s , symmetrically. Three different geometrical parameters, which were the edge distance-to-hole diameter ratio ( E/ D), plate width-to-hole diameter ratio ( W/ D), and the distance between two serial holes-to-hole diameter ratio ( K/ D), were investigated, experimentally. Consequently, E/ D, W/ D, and K/ D ratios were designed from 1 to 5, 2 to 5, and 3 to 5, respectively. Additionally, the failure tests were performed for a range of preload moments as 2, 3, 4, 5Nm and without any preload moment as 0Nm. Experimental results showed that the changing of geometrical parameters and the presence of preload moments affected failure behaviour of two serial pinned/bolted composite joints. Furthermore, the numerical failure analysis was also carried out via Lusas 13.6 code. Hashin failure criterion was preferred to determine both bearing strengths and failure modes. All in all, a good agreement is observed between experimental and numerical failure analyses.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Mechanical Behavior of Composites · Structural Load-Bearing Analysis · Electronic Packaging and Soldering Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Aksaray University, Aksaray, Turkey
Department of Mechanical Engineering, Dokuz Eylul University, Bornova, Izmir, Turkey
References (25)
Show source-provided references
1. 10.1177/00219980303810810.1177/002199803038108 ↗
2. 10.1177/073168440504661110.1177/0731684405046611 ↗
3. 10.1177/00219983000340120410.1177/002199830003401204 ↗
4. 10.1016/S1359-8368(02)00054-910.1016/S1359-8368(02)00054-9 ↗
5. 10.1177/00219983820160060310.1177/002199838201600603 ↗
6. 10.1177/073168440707937910.1177/0731684407079379 ↗
7. 10.1177/073168440707976910.1177/0731684407079769 ↗
8. Mallick P K · 1993
9. 10.1016/j.compstruct.2005.06.00810.1016/j.compstruct.2005.06.008 ↗
10. 10.1016/S1359-835X(99)00002-010.1016/S1359-835X(99)00002-0 ↗
11. 10.1016/S0263-8223(03)00096-510.1016/S0263-8223(03)00096-5 ↗
12. 10.1016/S1359-835X(99)00090-110.1016/S1359-835X(99)00090-1 ↗
13. 10.1016/S0266-3538(02)00260-910.1016/S0266-3538(02)00260-9 ↗
14. 10.1016/S1359-835X(02)00023-410.1016/S1359-835X(02)00023-4 ↗
15. 10.1177/002199830303446110.1177/0021998303034461 ↗
16. 10.1177/073168440808949310.1177/0731684408089493 ↗
17. 10.1016/S0263-8223(02)00020-X10.1016/S0263-8223(02)00020-X ↗
18. 10.1016/j.compositesb.2004.11.00310.1016/j.compositesb.2004.11.003 ↗
19. 10.1016/j.matdes.2007.05.00910.1016/j.matdes.2007.05.009 ↗
20. Reddy J N · 1997
21. Jones R M · 1999
22. Gibson R F · 1994
23. Sen F · 2007
24. Matthews F L · 2000
25. LUSAS User's Manual. FEA Ltd. Forge House, 66 High Street, Kingston upon Thames, Surrey KT1 1HN, UK. 1999.