A new design method for asymmetrical head gradient coils used for superconducting MRI scanner*
Source abstract
Abstract
Abstract A novel approach of asymmetrical gradient coil design for head imaging in MRI (magnetic resonance imaging) is presented in this paper. The design is based on a modified target field method in which the stream function is introduced to replace Blaine's scheme for the length control. The transverse head coil calculated by this method has a high performance. The coil efficiency is 0.41 mT/m/A and the inductance is 512 μH. The coil has an inner diameter of 32 cm and a length of 45.8 cm. The size of the ROU (region of uniformity) is 20 cm along the transverse direction and 17 cm along the axial direction and it is close to one end of the coil. The ROU of the coil matches the ROI (region of interest) of human head very well. Compared with previous designs, our design has relatively high performance and the overlap between the ROU and the ROI is larger (the overlap percent is 95%).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced MRI Techniques and Applications · Atomic and Subatomic Physics Research · Advanced NMR Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. WhiteM.L.Diffusion imaging utilizing B-values up to 3000 using a high gradient strength scanner in normal subjects and stroke patients Radiology 1999213P14771477
2. HennigJ.Functional magnetic resonance imaging: A review of methodological aspects and clinical applications Journal of Magnetic Resonance Imaging 200318111
3. AbduljalilA.M.Torque free asymmetric gradient coils for echo planar imaging Magnetic Resonance in Medicine 199431450450
4. AlsopD.C.Optimization of torque-balanced asymmetric head gradient coils Magnetic Resonance in Medicine 199635875875
5. BowtellR.Analytic approach to the design of transverse gradient coils with co-axial return paths Magnetic Resonance in Medicine 199941600600
6. BlaineA.Design and fabrication of a three-axis edge ROU head and neck gradient coil Magnetic Resonance in Medicine 200044955955
7. BlaineA.Constrained length minimum inductance gradient coil design Magnetic Resonance in Medicine 199839270270
8. TomasiD.Asymmetrical gradient coil head imaging Magnetic Resonance in Medicine 200248707707
9. Turner, R. (1986) A target field approach to optimal coil design J. Phys. D: Appl. Phys., pp. L147 - L147.10.1088/0022-3727/19/8/001 ↗
10. Turner, R. (1988) Minimum inductance coils J. Phys. E: Sci. Instrum., pp. 948 - 948.10.1088/0022-3735/21/10/008 ↗
11. Turner, R. (1993) Gradient coil design: a review of methods Magnetic Resonance Imaging, 11, pp. 903 - 903.10.1016/0730-725X(93)90209-V ↗
12. Jin, J.M.(1998) Electromagnetic Analysis and Design in Magnetic Resonance Imaging. Boca Raton : CRC Press LLC.