journal article·2006-05-01

Development of novel and sensitive sensors based on microcantilever of atomic force microscope*

Jin Yan, Wang Kemin, Jin Rong

Progress in Natural Science· Volume 16· Issue 5
Publisher page

Abstract

Abstract Recently, the development of sensors based on microfabricated cantilevers of atomic force microscope (AFM) has attracted considerable attention from the designers of novel physical, chemical, and biological sensors. Many kinds of sensors have been developed talking the advantages of its high-resolution imaging, force measurement and force sensitivity, such as immunosensor and DNA biosensor and the sensors for detection of intermolecular interaction. This paper reviews the progress made in this field and discusses the signal transfer principles by which the design of the sensor is achived. * Supported by National Natural Science Foundation of China (Grant No. 20135010), the Major State Basic Research Development Program of china (2002CB513100-10), National High-Tech Project (2003AA302250) and Key project of Hunan Province Technology Plan (0399Y1006).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Force Microscopy Techniques and Applications · Mechanical and Optical Resonators · Advanced MEMS and NEMS Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Sepaniak, M. and Datskos, P. and Lavrik, N. and (2002) Microcantilever transducers: a new approach in sensor technology Analytical Chemistry, 74(21), pp. 568A - 575A.10.1021/ac022156i ↗
2. Tamayo, J. and Humphris, A. and Malloy, A. and (2001) Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor Ultramicroscopy, 86(1-2), pp. 167 - 173.
3. Jones, V. and Kenseth, J. and Porter, M. (1998) Microminiaturized immunoassaya using atomic force microscopy and compositionally patterned antigen arrays Analytical Chemistry, 70(7), pp. 1233 - 1241.
4. Li, L. and Chen, S. and Oh, S. and (2002) In situ single-molecule detection of antibody-antigen binding by tapping-mode atomic force microscopy Analytical Chemistry, 74(23), pp. 6017 - 6022.
5. Dong, Y. and Shannon, C. (2000) Hetergeneous immunosensing using antigen and antibody monolayers on gold sutstrate with electro-chemical and scanning probe detection Analytical Chemistry, 72(11), pp. 2371 - 2376.
6. Broening Kelley, M. and Wadu-Mesthrige, K. and Hari, V. and (1997) Atomic force microscopic study of specific antigen antibofy binding Langmuir, 13(2), pp. 343 - 350.
7. O'Brien, J. and Stickney, J. and Porter, M. (2000) Preparation and characterization of self-assembled double-stranded DNA (dsDNA) microarrays for protein: dsDNA screening using atomic force microscopy Langmuir, 16(24), pp. 9559 - 9567.
8. O'Brien, J. and Stcikney, J. and Prorter, M. (2000) Self-assembled double stranded DNA (dsDNA) microarrays for protein: dsDNA screening using atomic force microscopy Journal of the American Chemical Society, 122(20), pp. 5004 - 5005.
9. Schneider, S. and Folprecht, G. and Krohne, G. and (1995) Immunolocalizaton of lamins and nuclear pore complex proteins by atomic force microscopy Pflugers Arch., 430(5), pp. 795 - 801.
10. Yamashina, S. and Shigeno, M. (1995) Application of atomic force microscopy to ultrastructural and histochemical studied of fixed and embedded cells Journal of Electronic Microscopy, 44(6), pp. 462 - 466.
11. Möller, R. and Casáki, A. and Köhler, J. and (2000) DNA probes on chip surfaces studied by scanning force microscopy using specific binding of colloidal gold Nucleic Acids Research, 28(20), pp. e91.
12. Casáki, A. and Möller, R. and Straube, W. and (2001) DNA monolayer on gold substrates characterized by nanoparticle lageling and scanning force microscopy Nucleic Acids Research, 29(16), pp. e81.
13. Casáki, A. and Kaplanek, P. and Möller, R. and (2003) The optical detection of individual DNA-conjugated gold nanoparticle labels after metal enhancement Nanotechnology, 14(12), pp. 1262 - 1268.
14. Han, S. and Lin, J. and Zhou, F. and (2000) Oligonucleotide-capped gold-nanoparticles for improved atomic force microscopic imaging and enhanced selectivity in polynucleotide detection Biochemical and Biophysical Research Communication, 279(1), pp. 265 - 269.
15. Dammer, U and hegner, M. and Anselmetti, D. and (1996) Specific antigen antibody interaction measured by force microscopy Biophysical Journal, 70(5), pp. 2437 - 2441.
16. Schwesinger, F. and Ros, R. and Strunz, T. and (2000) Unbinding forces of single antibofy-antigen complexex correlate with their thermal dissociation rates Proceeding of the National Academy of Sciences of the United States of America, 97(18), pp. 9972 - 9977.
17. Ros, R. and Schwesinger, F. and Anselmetti, D. and (1998) Antigen binding forces of individually addressed single-chaing Fv antibody molecules Proceeding of the National Academy of Sciences of the United States of America, 95(13), pp. 7402 - 7405.
18. Florin, E. and Moy, V. and Gaub, H. (1994) Adhesion forces between indibidual ligand-receptor pairs Science, 264(5157), pp. 415 - 417.
19. Paris, R. and Strunz, T. and Oroszlan, K. and (2000) Force spectroscopy and dynamics of the biotin-avidin bond studied by scanning force microscopy Single Molecular, 4(1), pp. 285 - 290.
20. Moy, V. and Florin, E. and Gaub, H. (1994) Intermolecular forces and energies between ligands and receptors Science, 266(5183), pp. 257 - 259.
21. Lee, G. and Chrisey, L. and Colton, R. (1994) Direct measurement of the forces between complementary strands of DNA Science, 266(5186), pp. 771 - 773.
22. Boland, T. and Ratner, B. (1995) Direct measurement of hydrogen bonding in DNA nucleotide bases by atomic force microscopy Proc. Natl. Acad. Sci. USA, 92(12), pp. 5297 - 5301.10.1073/pnas.92.12.5297 ↗
23. Jin, Y and Wang, K. and Tan, W. and (2004) Monitoring molecular beacon/DNA interactions using atomic force microscopy Analytical Chemistry, 79(19), pp. 5721 - 5725.
24. Jiang, Y. and Zhu, C. and Ling, L. and (2003) Specific aptamer-protein interaction studied by atomic force microcopy Analytical Chemistry, 75(9), pp. 2112 - 2116.
25. Han, T. and Williams, J. and Jr Beebe, T. (1995) Chemical bonds studied with functionalized atomic force microscopy tops Analytica Chimica Acta, 307(2-3), pp. 365 - 376.
26. Noy, A. and Frisbie, C. and Rozsnyai, L. and (1995) Chemical force microscopy: exploiting chemically-modified tips to quantify adhesion, friction, and functional group distributions in molecular assemblies Journal of the American Chemical Society, 117(30), pp. 7943 - 7951.
27. Grandbois, M. and Beyer, M. and Rief, M. and (1999) How strong is a covalent bond? Science, 283(5408), pp. 1727 - 1730.
28. Tyagi, S. and Kramer, F. (1996) Molecular beacons: Probes that fluoresce upon hybridization Nature Biotechnology, 14, pp. 303 - 308.
29. Fang, X. and Jeffery Li, J. and Perlette, J. and (2000) Molecular beacons-Novel fluorscent probes Analytical Chemistry, 72(23), pp. 747A - 753A.10.1021/ac003001i ↗
30. Barnes, J. and Stephenson, R. and Welland, M. and (1994) Photothermal spectroscopy with femtojoule sensitivity using a micromechanical device Nature, 372(6501), pp. 79 - 81.
31. Thundat, T and Warmack, R. and Chen, G. and (1994) Thermal andambient-induced deflections of scanning force microscope cantilevers Applied Physics Letters, 64(21), pp. 2894 - 2896.
32. Xu, X. and Thundat, T. and Brown, G. and (2002) Detection of Hg2+ using microcantilever sensors Analytical Chemistry, 74(15), pp. 3611 - .3615.
33. Ji, H. and Finot, E. and Dabestani, R. and (2000) A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection Chemical Communication, 6, pp. 457 - 458.
34. Thundat, T. and Chen, G. and Warmack, R. and (1995) Vapor detection using resonating microcantilevers Analytical Chemistry, 67(3), pp. 519 - 521.
35. Datskos, P. and Sauers, I. (1999) Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers Sensors & Actuators: B, 61(1-3), pp. 75 - 82.
36. Berger, R. and Lang, H. and Gerber, C. and (1998) Micromechanical thermogravimetry Chemical Physics Letters, 294(4-5), pp. 363 - 369.
37. Wu, G. and Datar, R. and Hansen, K. and (2001) Bioassay of prostate-specific antigen (PSA) using microcantilevers Nature Biotechnology, 19(9), pp. 856 - 860.
38. Arntz, Y. and Seelig, J. and Lang, H. and (2003) Label-free protein assay based on a nanomechnaical cantilever array Nanotechnology, 14(1), pp. 86 - 90.
39. Grogan, C. and Raiteri, R and O'Connor, G. and (2002) Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor Biosensors and Bioelectronics, 17(3), pp. 201 - 207.
40. Su, M. and Li, S. and Dravid, P. (2003) Microcantilever resonance-based DNA detection with nanoparticle probes Applied Physics Letters, 82(20), pp. 3562 - 3564.
41. Hagan, M. and Majumdar, A. and Chakraborty, A. (2002) Nanomechanical forces generated by surface grafted DNA The Journal of Physical Chemistry B, 106(39), pp. 10163 - 10173.
42. Hansen, K. and Ji, H. and Wu, G. and (2001) Cantilever-based optical deflection assay for discrimination of DNA The Journal of Physical Chemistry, 73(7), pp. 1567 - 1571.
43. Mckendry, R. and Zhang, J. and Arntz, Y. and (2002) Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array Proc. Natl. Acad. Sci. USA, 99(15), pp. 9783 - 9788.10.1073/pnas.152330199 ↗
44. Fritz, J. and Baller, M. and Lang, H. and (2000) Translating biomolecular recognition into nanomechanics Science, 288(5464), pp. 316 - 318.
45. Stevenson, K. and Mehta, A. and Sachenko, P. and (2002) Nanomechanical effect of enzymatic manipulation of DNA on microcantilever surfaces Langmuir, 18(23), pp. 8732 - 8736.
46. Zhang, Y. and Ji, H. and Brown, G. and (2003) Detection of CrO2-4 using a hydrogel swelling microcantilever sensor. Analytical Chemistry, 75(18), pp. 4773 - 4777.10.1021/ac0343026 ↗
47. Liu, K. and Ji, H. (2004) Detection of Pb2+ using a hydrogel swelling microcantilever sensor Analytical Science, 20(1), pp. 9 - 11.
48. Ji, H. and Hansen, K. and Hu, Z. and (2001) Detection of pH variation using modified microcantilever sensors Sensors & Actuators: B, 72, pp. 233 - 238.
49. Raiteri, R. and Butt, H. and Grattarola, M. (1998) Changes in surface stress measured with an atomic force microscope Scanning Microscopy, 12(1), pp. 243 - 251.
50. Raiteri, R. and Butt, H. (1995) Measuring electrochemically induced surface stress with an atomic force microscopy The Journal of Physical Chemistry, 99(43), pp. 15728 - 15732.
51. Raiteri, R. and Butt, H. and Grattarola, M. and (2000) Changes in surface stress at the liquid/solid interface measured with a microcantilever Electrochemica Acta, 46(2-3), pp. 157 - 163.