Design methodology for the frequency shift method of islanding prevention and analysis of its detection capability
Source abstract
Abstract
Islanding protection is one of the most important sources of discrepancy in grid-connected photovoltaic systems. Even when islanding is not very likely to happen, regulations demand the photovoltaic inverters to implement effective protection methods. Due to its several advantages, the frequency shift method of islanding prevention, commonly known as Sandia Frequency Shift, is one of the most important active methods. This method implements a positive feedback of the frequency that tends to move it outside the trip limits in case of islanding. The method shows a very high detection capability, which depends on both the values of the method parameters and the characteristics of the load that remains in the same power section after islanding. This paper develops a mathematical analysis of the Sandia Frequency Shift method and proposes a new methodology to design its parameters as a trade-off between the detection capability, which is evaluated as a function of the load characteristics, and the distortion that the method could introduce in the grid as a consequence of transitory frequency disturbances. The ability of this methodology to design the method parameters and achieve the highest detection capability is satisfactorily proved by means of both simulation and experimental results on a commercial photovoltaic inverter that implements the method once its parameters have been designed with the proposed methodology. Copyright © 2005 John Wiley & Sons, Ltd.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Islanding Detection in Power Systems · Power Systems Fault Detection · Microgrid Control and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. , , , , . Development and testing of an approach to anti-islanding in utility-interconnected photovoltaic systems. Sandia National Laboratories, USA, August 2000.
2. Ropp · Progress in Photovoltaics: Research and Applications · 1999 · 7 · 3910.1002/(SICI)1099-159X(199901/02)7:1<39::AID-PIP246>3.0.CO;2-J ↗
3. , , . Risk analysis of islanding of photovoltaic power systems within low voltage distribution networks. Report IEA-PVPS T5-08, March 2002.
4. . Universal Interconnection Technology Workshop Proccedings, U.S. Department of Energy, Chicago, USA, 2002; 59-66.
5. Woyte · Progress in Photovoltaics: Research and Applications · 2003 · 11 · 40710.1002/pip.503 ↗
6. , , , . Determining the sufficiency of standard protective relaying for islanding prevention in grid-connected PV systems. Proceedings of the 2nd World Conference and Exhibition on Photovoltaic Solar Energy Conversion, Vienna, Austria, 1998; 2519-2524.
7. . Probability of islanding in utility networks due to grid connected photovoltaic power systems. IEA Report PVPS T5-07: 2002, 2002.
8. , . Statistical evaluation of optimum islanding preventing method for utility interactive small scale dispersed PV Systems. Proceedings of the IEEE Photovoltaic Specialists Conference, Hawaii, 1994; 1085-1088.
9. , , , , . Method for preventing islanding phenomenon on utility grid with a number of small scale PV systems. Proceedings of the IEEE Photovoltaic Specialists Conference, Las Vegas, Nevada, 1991; 695-700.
10. . Design issues for grid-connected photovoltaic systems. PhD Dissertation, Georgia Institute of Technology, Atlanta, USA, 1998.
11. Ropp · IEEE Transactions on Energy Conversion · 1999 · 14 · 81010.1109/60.790956 ↗
12. Hung · IEEE Transactions on Energy Conversion · 2003 · 18 · 16910.1109/TEC.2002.808412 ↗
13. . SUNSINE300, utility interactive AC module anti-islanding test results. Proceedings of the IEEE 26th Photovoltaic Specialists Conference, Anaheim, California, 1997; 1265-1268.
14. Ropp · Proceedings of the IEEE Transactions on Energy Conversion · 2000 · 15 · 29010.1109/60.875495 ↗
15. Woyte · IEEE Transactions on Energy Conversion · 2003 · 18 · 15710.1109/TEC.2002.808410 ↗
16. , . Anti-islanding protection of grid connected PV inverters, Proceedings of the 34th Universities Power Engineering Conference UPEC'99, Leicester, United Kingdom, 1999; 378-382.
17. , . Proposals for an international islanding detection standard. Proceedings of the World Renewable Energy Congress, Cologne, Germany, 2002.
18. , . Evaluation of islanding detection methods for photovoltaic utility-interactive power systems. IEA Report PVPS T5-09: 2002, 2002.
19. . Utility aspects of grid connected photovoltaic power systems. IEA Report PVPS T5-01: 1998, 1998.
20. , , , . Five years of ENS (MDS) islanding protection—what could be the next steps? Proceedings of the 17th European Photovoltaic Solar Energy Conference and Exhibition, Munich, Germany, 2001; 2544.
21. Yuyama · Solar Energy Materials and Solar Cells · 1994 · 35 · 47710.1016/0927-0248(94)90176-7 ↗
22. Okado · Electrical Engineering in Japan · 1995 · 115 · 6010.1002/eej.4391150405 ↗
23. . Protection device for stopping operation of an inverter, US Patent 5493485, December 29, 1993.
24. Smith · IEE Proceedings on Electric Power Applications · 2000 · 147 · 1510.1049/ip-epa:20000018 ↗
25. , , , . Results of Sandia National Laboratories grid-tied inverter testing, Sandia National Laboratories. Proceedings of the 2nd World Conference and Exhibition on Photovoltaic Solar Energy Conversion, Vienna, Austria, 1998.
26. Huang · IEE Proceedings-Generation, Transmission and Distribution · 2001 · 148 · 24310.1049/ip-gtd:20010161 ↗
27. IEEE Std 929-2000. IEEE Recommended practice for utility interface of photovoltaic (PV) systems. Institute of Electrical and Electronics Engineers, New York, USA, 2000.
28. Automatic disconnecting facility for photovoltaic installation with a rated output ≤4·6 kV A and a single-phase parallel feed by means of an inverter into the public low-voltage mains. German National Standard DIN VDE 0126, 1999.
29. UL 1741. UL Standard for safety for static converters and charge controllers for use in photovoltaic power systems. Underwriters Laboratories Inc., Northbrook, USA, 1999, revised January 2001.
30. IEEE Draft Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE P1547/D07. Institute of Electrical and Electronics Engineers, 2001.
31. Recommendation for the connection of small-scale embedded generators (up to 16 A per phase) in parallel with public low-voltage distribution networks, United Kingdom Engineering Recommendations G83, 2003.