journal article·2015-05

Intrinsically radiopaque polyurethanes with chain extender 4,4′-isopropylidenebis [2-(2,6-diiodophenoxy)ethanol] for biomedical applications

S Dawlee, M Jayabalan

Publisher page

Abstract

Radiopaque polyurethanes are used for medical applications as it allows post-operative assessment of the biomaterial devices using X-ray. Inherently, radiopaque polyurethanes based on polytetramethylene glycol (PTMG), polypropylene glycol, 4,4′-methylenebis(phenyl isocyanate), and a new iodinated chain extender 4,4′-isopropylidenebis[2-(2,6-diiodophenoxy)ethanol] with flexible spacers were synthesized and characterized. The iodinated polyurethanes were clear, optically transparent, and had high molecular weights. The polyurethanes also possessed excellent radiopacity and high thermal stability. The biocompatibility of the most promising iodinated polyurethane was evaluated both in vitro (cytotoxicity evaluation by direct contact and MTT assay, using L929 mouse fibroblast cells) and in vivo (toxicology studies in rabbits and subcutaneous implantation in rats). The material was nontoxic and well tolerated by the animals. Thus, these radiopaque and transparent polyurethanes are expected to have potential for various biomedical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Polymer Science Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Kerala, India

References (34)

Show source-provided references
1. Lamba NMK · 1998
2. Gogolewski S · 1996 · 657
3. 10.1097/00004424-199905000-0000110.1097/00004424-199905000-00001 ↗
4. 10.1002/(SICI)1097-0126(199706)43:2<143::AID-PI717>3.0.CO;2-M10.1002/(SICI)1097-0126(199706)43:2<143::AID-PI717>3.0.CO;2-M ↗
5. 10.1016/j.actbio.2008.06.00910.1016/j.actbio.2008.06.009 ↗
6. 10.1002/app.1218710.1002/app.12187 ↗
7. 10.1016/j.biomaterials.2009.06.03810.1016/j.biomaterials.2009.06.038 ↗
8. 10.1002/jbm.a.3160110.1002/jbm.a.31601 ↗
9. 10.1002/app.1992.07044042110.1002/app.1992.070440421 ↗
10. 10.1016/j.biomaterials.2007.03.02510.1016/j.biomaterials.2007.03.025 ↗
11. 10.1016/j.biomaterials.2005.05.09910.1016/j.biomaterials.2005.05.099 ↗
12. 10.1007/s10856-008-3557-410.1007/s10856-008-3557-4 ↗
13. 10.1002/app.3645710.1002/app.36457 ↗
14. 10.1177/088532821143409010.1177/0885328211434090 ↗
15. 10.1088/1748-6041/6/5/05500210.1088/1748-6041/6/5/055002 ↗
16. 10.1016/j.biomaterials.2009.06.04910.1016/j.biomaterials.2009.06.049 ↗
17. 10.1002/pola.2464910.1002/pola.24649 ↗
18. 10.1002/jbm.a.3429510.1002/jbm.a.34295 ↗
19. 10.1002/jbm.a.3499710.1002/jbm.a.34997 ↗
20. 10.1002/jbm.a.3477710.1002/jbm.a.34777 ↗
21. 10.1021/jo00305a02610.1021/jo00305a026 ↗
22. 10.1002/jbm.a.3160110.1002/jbm.a.31601 ↗
23. Biological evaluation of medical devices. Part 10. Test for irritation and delayed type hypersensitivity: Intracutaneous Reactivity Test, ISO-10993-10, Geneva, 2002.
24. Biological evaluation of medical devices. Part 6. Tests for local effects after implantation, ISO-10993-6, Geneva, 2007.
25. 10.1021/bm000292w10.1021/bm000292w ↗
26. Zhao Jonathon Z. Biocompatible polymeric contrast agents and radiopaque materials for medical devices. Patent No. 8,197,796, 2008.
27. 10.1016/S0142-9612(01)00197-110.1016/S0142-9612(01)00197-1 ↗
28. 10.1002/(SICI)1097-4628(19971114)66:7<1251::AID-APP5>3.0.CO;2-F10.1002/(SICI)1097-4628(19971114)66:7<1251::AID-APP5>3.0.CO;2-F ↗
29. 10.1002/1097-4636(20010915)56:4<516::AID-JBM1123>3.0.CO;2-B10.1002/1097-4636(20010915)56:4<516::AID-JBM1123>3.0.CO;2-B ↗
30. 10.1016/j.actbio.2010.02.03610.1016/j.actbio.2010.02.036 ↗
31. 10.1016/j.actbio.2004.11.00510.1016/j.actbio.2004.11.005 ↗
32. 10.1002/jbm.82028070910.1002/jbm.820280709 ↗
33. 10.1002/jbm.82026080510.1002/jbm.820260805 ↗
34. 10.1016/S0169-409X(96)00404-810.1016/S0169-409X(96)00404-8 ↗