journal article·1996-01

A novel MMC-loaded pHEMA drainage device for the treatment of glaucoma: in vitro and in vivo studies

Menemşe Kiremitçi-Gümüşderelioglu, Meltem Gökçe, R. Fikret Akata

Publisher page

Abstract

Administration of subconjunctival 5-fluorouracil (5-FU) and topical mitomycin-C (MMC) has been shown to improve the success rate of glaucoma-filtering surgery. However, corneal toxicity and administrative problems remain. To overcome this limitation, drainage devices for the sustained release of 5-FU and MMC were designed and tested in vitro and in vivo. This paper presents only the results of our studies which were carried out on MMC-loaded devices. Here, the drainage devices were prepared from MMC-loaded poly(hydroxyethyl methacrylate) (pHEMA) matrices in different cross-linking ratios and in different drug loading capacities, i.e. 0.2, 0.5, and 2.0 mg MMC per device. These devices released MMC at approximately 6.0-90.0 micrograms day-1 for over 2 months depending on cross-linking density and initial drug loading. The diffusional release of MMC from glassy and swollen copolymers showed that diffusion mechanism is Fickian in both cases. The usability of the pHEMA implants were investigated by in vivo experiments which were done on eight dog's eye. In the treatment eyes, intraocular pressures remained significantly lower than the control eyes throughout the experimental period (4 months). Subconjunctival implantations revealed no clinical and histological evidence for toxicity. The results of in vitro and in vivo studies indicate that an implantable release system delivering MMC for over 2 months can improve the prognosis for filtering surgery by preventing postoperative fibrosis.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Corneal Surgery and Treatments · Glaucoma and retinal disorders · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

a Hacettepe University, Chemical Engineering Department, 06532 Beytepe, Ankara, Turkey

b Hacettepe University, Chemical Engineering Department, 06532 Beytepe, Ankara, Turkey

c Gazi University, Department of Ophthalmology, Ankara, Turkey

References (21)

Show source-provided references
1. Krupin T. · 1994
2. Wright M. M. · 1994
3. Rootman J. · Arch. Ophthalmol. · 1979 · 97 · 237510.1001/archopht.1979.01020020591019 ↗
4. Hutchinson A. K. · Arch. Ophthalmol. · 1994 · 112 · 7410.1001/archopht.1994.01090130084023 ↗
5. Simmons S. T. · Br. J. Ophthalmol. · 1988 · 72 · 68810.1136/bjo.72.9.688 ↗
6. Hasty B. · Am. J. Ophthalmol. · 1990 · 109 · 72110.1016/S0002-9394(14)72443-2 ↗
7. Lee D. A. · Ophthalmology · 1987 · 94 · 152310.1016/S0161-6420(87)33251-8 ↗
8. Merkli A. · and R.Gurny, J. Control. Rel. · 1994 · 29 · 10510.1016/0168-3659(94)90126-0 ↗
9. Blandford D. L. · Invest. Ophthalmol. Visual Sci. · 1992 · 33 · 3430
10. Gökçe M. · 1994
11. Gökçe . M. · Biomaterials · 1996
12. Gregonis D. E. · 1976
13. Peppas N. A. · J. Biomed. Mater. Res. · 1985 · 19 · 39710.1002/jbm.820190405 ↗
14. Skuta G. L. · Ophthalmology · 1992 · 99 · 43810.1016/S0161-6420(92)31951-7 ↗
15. Denizli A. · Biomaterials · 1988 · 9 · 36310.1016/0142-9612(88)90034-8 ↗
16. Kiremitci, M., Oncu, A., Denizli, A. and Piskin, E. 1986. Progress in Artificial Organs-1985, Edited by: Nose, Y., Kjellstrand, C. and Ivanovich, P. 1010Cleveland, OH: ISAO Press.
17. Trigo R. H. · Biomaterials · 1994 · 15 · 118110.1016/0142-9612(94)90240-2 ↗
18. Peppas N. A. · J. Polym. Sci.: Polym. Phys. Edn · 1983 · 21 · 983
19. Davidson III R. G. W. · J. Control. Rel. · 1986 · 3 · 24310.1016/0168-3659(86)90096-9 ↗
20. Davidson III R. G. W. · J. Control. Rel. · 1986 · 3 · 25910.1016/0168-3659(86)90097-0 ↗
21. Merkli A. · J. Control. Rel. · 1995 · 33 · 41510.1016/0168-3659(94)00117-D ↗