Quantitative analysis of interconnectivity of porous biodegradable scaffolds with micro‐computed tomography
Source abstract
Abstract
Abstract Pore interconnectivity within scaffolds is an important parameter influencing cell migration and tissue ingrowth needed to promote tissue regeneration. Methods for assessment of interconnectivity are usually qualitative, restricted to two‐dimensional images, or are destructive. Microcomputed tomography nondestructively provides three‐dimensional (3D) images of intact specimens at high spatial resolutions. We describe an image analysis technique for quantitative assessment of scaffold interconnectivity. Scaffolds were made via a particulate leaching process with 75%, 80%, 85%, and 88% volumetric porogen fractions. Specimens were scanned and resulting 3D, digital images were analyzed with a custom algorithm. A series of virtual, idealized scaffolds were also created for illustration of the algorithm's analysis approach and for its validation. The program calculated accessible void fractions over a range of minimum connection sizes. In real specimens, nearly 100% of the porous volume was connected with outside air for connections greater than or equal to 20 μm in their smallest dimension. In scaffolds made with 75% porogen, the accessible void fraction decreased to 78% if only those connections greater than or equal to 260 μm were considered. The relationship between accessible void fraction and connection size varied as a function of porogen content. The interconnectivity parameter described here may have implications for cell migration and tissue growth into scaffolds. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 71A: 258–267, 2004
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. 10.1089/10763270175333764510.1089/107632701753337645 ↗
2. 10.1016/0021-9290(95)00010-010.1016/0021-9290(95)00010-0 ↗
3. 10.1002/jbm.a.1045310.1002/jbm.a.10453 ↗
4. 10.1089/10763270275350304510.1089/107632702753503045 ↗
5. 10.1016/S8756-3282(02)00983-310.1016/S8756-3282(02)00983-3 ↗
6. 10.1007/s00776005012610.1007/s007760050126 ↗
7. Micro‐CT imaging of structure‐to‐function relationship of bone microstructure and associated vascular involvement10.3233/THC-1998-65-612 ↗
8. 10.1152/ajpheart.1998.275.3.H110310.1152/ajpheart.1998.275.3.H1103 ↗
9. 10.1109/42.88784310.1109/42.887843 ↗
10. 10.1016/S0142-9612(02)00361-710.1016/S0142-9612(02)00361-7 ↗
11. 10.1016/S0142-9612(02)00276-410.1016/S0142-9612(02)00276-4 ↗
12. 10.1089/10763270175321318310.1089/107632701753213183 ↗
13. 10.1163/15685620232081382810.1163/156856202320813828 ↗
14. 10.1002/(SICI)1097-4628(19971107)66:6<1123::AID-APP13>3.0.CO;2-210.1002/(SICI)1097-4628(19971107)66:6<1123::AID-APP13>3.0.CO;2-2 ↗
15. 10.1163/15685620131688347610.1163/156856201316883476 ↗
16. 10.1117/12.48023210.1117/12.480232 ↗
17. 10.1002/jbmr.565004010310.1002/jbmr.5650040103 ↗
18. 10.1016/0895-6111(89)90285-110.1016/0895-6111(89)90285-1 ↗
19. 10.1007/BF0316871110.1007/BF03168711 ↗
20. 10.1002/sca.495019040210.1002/sca.4950190402 ↗
21. LinCL MillerJD.Network analysis of filter cake pore structure by high resolution x‐ray microtomography. In: 1st World Congress on Industrial Process Tomography;1999April 14–17; Buxton UK.
22. 10.1109/TPAMI.1987.476794110.1109/TPAMI.1987.4767941 ↗
23. 10.1016/0031-3203(93)90135-J10.1016/0031-3203(93)90135-J ↗
24. 10.1117/12.53592710.1117/12.535927 ↗