Abstract We conducted an in vivo experiment to evaluate the resorption rate of a calcium phosphate cement (CPC) with macropores larger than 100 μm, using the CPC called Biocement D (Merck Biomaterial, Darmstadt, Germany), which after setting only shows pores smaller than 1 μm. The gas bubble method used during the setting process created macroporosity. Preset nonporous and porous cement implants were inserted into the trabecular bone of the tibial metaphysis of goats. The size of the preset implants was 6 mm and the diameter of the drill hole was 6.3 mm, leaving a gap of 0.3 mm between implant surface and drill wall. After 2 and 10 weeks, the animals were euthanized and cement implants with surrounding bone were retrieved for histologic evaluation. Light microscopy at 2 weeks revealed that the nonporous implants were surrounded by connective tissue. On the cement surface, we observed a monolayer of multinucleated cells. Ten weeks after implantation, the nonporous implants were still surrounded by connective tissue. However, a thin layer of bone now covered the implant surface. No sign of cement resorption was observed. In contrast, the porous cement evoked a completely different bone response. At 2 weeks, bone formation had already occurred inside the implant porosity. Bone formation even appeared to occur as a result of osteoinduction. Also, at their outer surface, the porous implants were completely surrounded by bone. At 2 weeks, about 31% of the initial cement was resorbed. After 10 weeks, 81% of the initial phosphate cement was resorbed and new bone was deposited. On the basis of these observations, we conclude that the creation of macropores can significantly improve the resorption rate of CPC. This increased degradation is associated with almost complete bone replacement. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 30–36, 2003
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Calcium Carbonate Crystallization and Inhibition · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. BrownWE ChowLC. US Patent No. 4 518 430;1985.
2. 10.1002/jbm.82029121010.1002/jbm.820291210 ↗
3. 10.1002/jbm.1002910.1002/jbm.10029 ↗
4. 10.1034/j.1600-0501.2002.130311.x10.1034/j.1600-0501.2002.130311.x ↗
5. 10.1111/j.1749-6632.1988.tb38519.x10.1111/j.1749-6632.1988.tb38519.x ↗
6. Cellular mechanisms of calcium phosphate ceramic degradation
7. 10.1002/1097-4636(2001)58:3<329::AID-JBM1025>3.0.CO;2-910.1002/1097-4636(2001)58:3<329::AID-JBM1025>3.0.CO;2-9 ↗
8. 10.1097/00006534-197905000-0000410.1097/00006534-197905000-00004 ↗
9. 10.1002/jor.110003030610.1002/jor.1100030306 ↗
10. Porous hydroxyapatite and tricalcium phosphate cylinders with two different pore size ranges implanted in the cancellous bone of rabbits10.1097/00003086-198807000-00017 ↗
11. del RealRP WolkeJGC Vallet‐RegíM JansenJA.A new method to produce macropores in calcium phosphate cements. Submitted for publication.
12. 10.1002/(SICI)1097-4636(199724)38:4<356::AID-JBM8>3.0.CO;2-N10.1002/(SICI)1097-4636(199724)38:4<356::AID-JBM8>3.0.CO;2-N ↗
13. 10.3109/1052029880910717910.3109/10520298809107179 ↗
14. 10.1016/S0142-9612(99)00075-710.1016/S0142-9612(99)00075-7 ↗
15. Sintered porous hydroxyapatites with intrinsic osteoinductive activity: Geometric induction of bone formation